MyQ LiftMaster CAPAC Manuel utilisateur

1
Smart Access Hub
INSTALLATION MANUAL
Model CAPAC

2
To reduce the risk of SEVERE INJURY or DEATH:
• Disconnect power at the fuse box BEFORE proceeding.
• To AVOID damaging gas, power or other underground utility
lines, contact underground utility locating companies BEFORE
digging.
• ALL electrical connections MUST be made by a qualified
individual.
• ALL power and control wiring MUST be run in separate
conduit.
To protect against fire and electrocution:
• Disconnect power BEFORE installing or servicing CAPAC.
• NEVER connect a keypad/reader or lock to doors without first
consulting the applicable fire code.
• You MUST consult with, and get approval from, local
authorities having jurisdiction BEFORE installing locks or
devices on ANY doors that may be fire exits.
• Use of egress push buttons may not be legal. Single action
exits may be required.
• ALWAYS obtain proper permits and approvals in writing
BEFORE installing equipment.
Safety
Safety Symbol and Signal Word Review
When you see these Safety Symbols and Signal Words on
the following pages, they will alert you to the possibility of
serious injury or death if you do not comply with the warnings
that accompany them. The hazard may come from something
mechanical or from electric shock. Read the warnings carefully.
When you see this Signal Word on the following pages, it will alert
you to the possibility of damage to your property or product if you
do not comply with the cautionary statements that accompany it.
Read them carefully.
MECHANICAL
ELECTRICAL
WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer
or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

3
PRE-INSTALL NETWORKINSTALL ACCESS CONTROLINTRODUCTION
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION
Carton Inventory ........................................................... 4
Tools Needed ................................................................ 4
Overview ....................................................................... 5
Electrical Specifications................................................. 6
Internet Requirements................................................... 7
PRE-INSTALL
1
Setup a myQ®Business™ Account ............................... 8
INSTALL
2
Wall Installation............................................................. 9
External Antenna Installation......................................... 9
Connect Power............................................................ 10
Gate Access................................................................. 11
Door Access................................................................ 12
Door Access - Vestibule.............................................. 13
Wiegand Output .......................................................... 14
NETWORK
3
Connect Internet.......................................................... 15
ACCESS CONTROL
4
Diagnostics ................................................................. 16
Accessories................................................................. 17
Legal Disclaimers........................................................ 17
Warranty ..................................................................... 18
myQ®Community Control
myQ®Smart Community Access Technology enables secure monitoring and control of gated
community or MDUs access points and other myQ®Smart Community Access devices with a
smartphone, tablet or computer.
Alerts can be received as email notifications, ensuring the status of access points.

4
Tools Needed
• PH2 Phillips Screwdriver
• Precision 1/8” Flat or PH0 Phillips Screwdriver
• 5/16” Nut driver
• Drill/Driver
• 1/8” Drill Bit
• Hammer Drill Bits for Drill/Driver
• RJ45 Crimping Pliers
• Multimeter
• Measuring tape
PROVIDED (NOT SHOWN)
• Installation Manual
Carton Inventory
PRE-INSTALL NETWORKINSTALL ACCESS CONTROLINTRODUCTION
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
Additional Tools Recommended
• Network LAN Cable Tester
• Wi-Fi Analyzer App (Smart Phone App)
• Network Analyzer software
INPUTOUTPUT WIEGAND
GATE
SDA SCL
OUTPUT
NO COM NC NO COM NC
1 2
D1 COM D0 D1 COM D0
1 2
WIEGAND
1 GND 2
INPUT
GND 12V-24V
POWER
POWER ETHERNET
Resistors 1K (4)
CAPAC Device Paddle Antennas (2)

5
INPUTOUTPUT WIEGAND
GATE
SDA SCL
OUTPUT
NO COM NC NO COM NC
1 2
D1 COM D0 D1 COM D0
1 2
WIEGAND
1 GND 2
INPUT
GND 12V-24V
POWER
POWER ETHERNET
PRE-INSTALL NETWORKINSTALL ACCESS CONTROLINTRODUCTION
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
Overview
INPUT/OUTPUT USED FOR
Relay Output 1 Gate Operator, Door Strikes, Maglocks, Lights (For control only. Power
to be provided by external power supply), Alarm Shunt
Relay Output 2
Wiegand Output 1 26-bit, 30-bit, 32-bit MiFare, 37-bit
Wiegand Output 2
Input 1 Closed Door Sensor (Supervised EOL or unsupervised),
Closed Limit Gate Sensor (Supervised EOL or unsupervised),
Open Limit Gate Sensor (Supervised EOL or unsupervised)
Input 2
Ethernet Port
Power Adapter Port
Mounting LocationMounting Location
LED Status Indicators
Reset/Learn Button (back)
External Antennas
NOTE: For UL installations, only UL 325 Listed gate operators, UL 294 Listed electric door strikes or
UL 294 Listed maglocks may be connected to relay output 1 or 2.
NOTE: For UL installations, only a Listed UL 294 access control unit may be connected to Wiegand
output 1 or 2.

6
PRE-INSTALL NETWORKINSTALL ACCESS CONTROLINTRODUCTION
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
Electrical Specifications
CAPAC SPECIFICATIONS
CAPAC Capacity Resident Capacity 50,000 (cloud)
Supply Voltage 6-24VDC
Operating Current 0.7A (max at 7.5VDC, 0.2A max at 24VDC)
CAPAC Operating
Temperature Range -29°C to 54°C (-20°F to 130°F)
Enclosure ABS Plastic
Storage and Shipping
Temperature Range -40°C to 85°C (-40°F to 185°F)
Wiegand Outputs (2) 26-bit, 30-bit, 32-bit MiFare, 37-bit
2 Primary and 2 Auxiliary
Relay Outputs SPDT, Rated Load - 2A at 30VDC (each)
Accessory Compatibility Refer to accessory page for compatible accessories
Network Compatibility 10/100 Ethernet
Wi-Fi®Compatibility 802.11b/g/n
Wi-Fi®Security WPA2 Personal (AES) and WPA3 Personal
Wi-Fi®Range Up to 250 feet (76.2 m), Open Air/Line-of-Sight to CAPAC (range will vary depending on obstructions)

7
PRE-INSTALL NETWORKINSTALL ACCESS CONTROLINTRODUCTION
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
Internet Requirements
When selecting a router, use the information below to ensure compatibility.
MODEL: CAPAC - Smart Access Hub
CAPAC can be connected to a router via a wired connection or Wi-Fi. LiftMaster recommends a minimum upload/download speed of
1Mbps for each CAPAC.
NOTE: This upload speed should be met when considering usage of other devices on the network like cameras and computers.
CAPAC WI-FI SECURITY COMPATIBILITY
• WPA3 Personal
• WPA2 Personal (AES)
ADDITIONAL COMPATIBILITY CONSIDERATIONS:
• If using a Wi-Fi signal strength tool or app, a continuous Wi-Fi signal strength connection of at least -65 DBM (numbers closer to zero are
stronger strength) at the CAPAC must be guaranteed to ensure an acceptable connection to the local network.
• Hidden network SSIDs are not supported.
• Wi-Fi networks requiring secondary authentication are not supported (E.g. Hotels and airport Wi-Fi).
• When checking signal strength in myQ Business, we recommend at least two bars.
CAPAC IS COMPATIBLE WITH ROUTERS USING THE
FOLLOWING Wi-Fi COMMUNICATION PROTOCOLS:
• 802.11b
• 802.11g
• 802.11n @ 2.4 GHz

8
PRE-INSTALL NETWORKINSTALL ACCESS CONTROLINTRODUCTION
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
Setup a myQ®Business™Account
NOTE: If you have an existing myQ®account, your myQ®Business™account will have the same password. Go to:
account.myQ.com and login.
1. If you do not have a myQ®Business™ account, call LiftMaster Customer Care at 800-323-2276 to activate a
myQ®Business™ account.
Be prepared by reviewing the information required on the Installation Readiness Survey:
2. You will get a welcome email from LiftMaster. Accept the invitation and register or login to your account.
3. Setup the facility, select a subscription plan, add residents, and credentials
(refer to the available Help in myQ®Business™).
4. Continue with the installation of the CAPAC in this manual.
The following services are required for CAPAC to fully function
For Support, call 877-247-6764 or visit https://support.partner.liftmaster.com/s/community-access-support
For more information use your smartphone to scan the QR code.

9
Wall Installation
External Antenna Installation
1. Drill (2) pilot holes, spaced 7 in. (17.78 cm) apart, on the wall where the device will be mounted.
2. Use (2) #6 Phillips mounting screws (not included) to attach the device to the wall.
NOTE: For exterior mounting, LiftMaster recommends the use of a polycarbonate NEMA enclosure.
For best cellular coverage position the antennas in the orientation
shown below (perpendicular to each other).
PRE-INSTALL NETWORKINSTALL ACCESS CONTROLINTRODUCTION
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INPUTOUTPUT WIEGAND
GATE
SDA SCL
OUTPUT
NO COM NC NO COM NC
1 2
D1 COM D0 D1 COM D0
1 2
WIEGAND
1 GND 2
INPUT
GND 12V-24V
POWER
POWER ETHERNET
7 in. (17.78 cm) 1.3 in. (3.3 cm)

10
Connect Power
• DO NOT connect the power supply to a switched outlet or
otherwise controlled AC outlet.
• DO NOT connect the power supply to the 120 Vac outlet until
ALL wiring is completed.
Connect 12VDC (7.5 W minimum) power supply to the Power input
connector.
OR
Connect power via power supply connector port.
NOTE: In UL installations the CAPAC shall be powered from the
power limited output of a UL 294 Listed power supply, a UL 603
Listed power supply, a UL 294 Listed access control unit or a UL
325 gate operator.
See the Electrical Specifications table
for detailed power requirements. AC/DC Power Supply
6-24VDC
OR
PRE-INSTALL NETWORKINSTALL ACCESS CONTROLINTRODUCTION
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INPUTOUTPUT WIEGAND
GATE
SDA SCL
OUTPUT
NO COM NC NO COM NC
1 2
D1 COM D0 D1 COM D0
1 2
WIEGAND
1 GND 2
INPUT
GND 12V-24V
POWER
POWER ETHERNET
Terminal Block Power
12-24VDC
To reduce the risk of SEVERE INJURY or DEATH:
• Disconnect power at the fuse box BEFORE proceeding.
• To AVOID damaging gas, power or other underground utility
lines, contact underground utility locating companies BEFORE
digging.
• ALL electrical connections MUST be made by a qualified
individual.
• ALL power and control wiring MUST be run in separate
conduit.
• ANY maintenance to the CAPAC or in the area near the CAPAC
MUST NOT be performed until disconnecting the electrical
power. Upon completion of maintenance the area MUST be
cleared and secured, at that time the unit may be returned to
service.
• CAPAC MUST be properly grounded and connected in
accordance with national and local electrical codes. NOTE:
The CAPAC should be on a separate fused line of adequate
capacity.
• All power wiring should be on a dedicated circuit and well
protected. The location of the power disconnect should be
visible and clearly labeled.
To protect against fire and electrocution:
• Disconnect power BEFORE installing or servicing CAPAC.
• NEVER connect a keypad/reader or lock to doors without first
consulting the applicable fire code.
• You MUST consult with, and get approval from, local fire
officials BEFORE installing locks or devices on ANY doors that
may be fire exits.
• Use of egress push buttons may not be legal. Single action
exits may be required.
• ALWAYS obtain proper permits and approvals in writing
BEFORE installing equipment.