Contents
General .......................................................................... 3
Symbols Used....................................................................3
Warnings ............................................................................3
Intended Use......................................................................4
Proper Environment...........................................................4
Glossary .............................................................................4
System Design, Connection Options ........................... 5
Sensor Cable, Optical Fiber...............................................5
Sensor Mounting, Mounting Adapter ................................6
Screw Terminals.................................................................7
RS422 8
Controller LEDs ............................................................. 8
Multifunction Button...........................................................9
Start of Measuring Range ..................................................9
Initial Operation........................................................... 10
Selecting the Sensor........................................................10
Performing the Dark Reference .......................................11
Positioning the Target ......................................................11
Measurement Configuration Selection ............................12
Checking the Video Signal ..............................................13
Signal Quality ..................................................................13
Distance Measurement with Website Display............ 14
One-Sided Thickness Measurement, Transparent
Target ........................................................................... 16
Preset ...............................................................................16
Material Selection.............................................................16
Video Signal .....................................................................17
Measurement Chart .........................................................18
RS422 Interface................................................................19
Ethernet Interface.............................................................19
RS422 Data Output, Ethernet ..........................................19
IP Address Assignment....................................................19
Service, Repair ............................................................ 20
Liability for Material Defects ...................................... 20

Page 3
General
confocalDT 2421 / 2422
General
Symbols Used
The following symbols are used in this document:
Indicates a hazardous situation which, if not avoided, may result in minor or
moderate injury.
Indicates a situation that may result in property damage if not avoided.
Indicates a user action.
iIndicates a tip for users.
Warnings
Connect the power supply and the display/output device according to the safety regulations for
electrical equipment.
> Risk of injury, damage to or destruction of the sensor and/or the controller
Avoid shocks and impacts to the sensor and controller.
> Damage to or destruction of the sensor and/or the controller
The supply voltage must not exceed the specified limits.
> Damage to or destruction of the sensor and/or the controller
Never kink optical fibers or bend them in tight radii.
> Damage to or destruction of the optical fiber, failure of measuring device
Protect the ends of the optical fiber against contamination (use protective caps).
> Incorrect measurement, failure of the measuring device
Protect the cable against damage.
Failure of the measuring device

Page 4
General
confocalDT 2421 / 2422
Intended Use
- The measuring system is designed for use in an industrial environment. It is used for
displacement, distance and movement measurement, thickness measurement,
measuring the position of parts or machine components
- The measuring system must only be operated within the limits specified in the technical data.
The measuring system must only be used in such a way that no persons are endangered or machines are dama-
ged in the event of malfunction or total failure of the sensor.
Take additional precautions for safety and damage prevention in case of safety-related applications.
Proper Environment
- Sensor protection class: IP40 ... IP65
- Controller protection class: IP40
Lenses are excluded from protection class. Contamination of the lenses causes impairment or failure of the function.
- Operating temperature range
Sensor: +5 ... +70 °C ( +41 ... +158 °F)
Controller: +5 ... +50 °C (+41 ... +122 °F)
- Storage temperature range: -20 ... +70 °C (-4 ... +158 °F)
- Humidity: 5 - 95 % (non-condensing)
- Ambient pressure: Atmospheric pressure
- EMC: As per EN 61000-6-3 / EN 61326-1 (Class B) Emitted interference; EN 61000-6-2 / EN 61326-1 Immunity to
interference
Glossary
SMR Start of measuring range MMR Mid of measuring range
MR Measuring range EMR End of measuring range
Minimum target thickness See Sensor Technical Data, Operating Instructions
Maximum target thickness Sensor measuring range x Refractive index of target

Page 5
System Design, Connection Options
confocalDT 2421 / 2422
System Design, Connection Options
Connect the components to one another, install the
sensors in the holders.
Patch cable
Run
BECKHOFF EK1122
X1
X2
230 VAC
PE
PS2020
N L
C240x
Optical fiber
Ethernet
EtherCAT
Controller
Sensor
PC
PS 2020
2-port EtherCAT
branch
Sensor Cable, Optical Fiber
The sensor is connected to the controller by means
of an optical fiber.
- Do not shorten or extend the optical fiber.
- Do not pull or carry the sensor by the cable.
Do not kink the sen-
sor cable.
Do not squash the
sensor cable, do
not use cable ties to
secure it.
Do not pull the sensor
cable over sharp
edges.
Do not pull on the
sensor cable.
The plugs may only be cleaned by persons with the
appropriate expertise.

Page 6
System Design, Connection Options
confocalDT 2421 / 2422
General Rules
Do not
- any contamination of the connector, e.g., dust
- apply any mechanical stress to the optical fiber
- curve the cable to a significant extent
Never bend the sensor cable more tightly than the per-
mitted bending radius.
R
If the cable is immova-
bly routed:
R = 30 mm or more
If the cable is movably
routed:
R = 40 mm or more
IFS2405 series sensor clam-
ped in an MA2405-x mounting
adapter
Sensor Mounting, Mounting Adapter
IFS240x optical sensors operate in the μm range.
i
Ensure careful handling during installation and
operation!
Install the IFS240x sensors using a mounting adap-
ter or on the mounting surface/mounting thread.
Sensor
IFS2402-x
IFS2403-x
IFS2404-2
IFS2404/90-2
IFS2407-0,1
IFS2405-0.3
IFS2405-1
IFS2406-3
IFS2406-10
IFS2405-3
IFS2405-6
IFS 2405-10
IFS 2407-3
IFS2405-28
IFS2405-30
IFS2406-2,5
IFS2407/90-0,3
Mounting
adapter
MA2400-27 •
MA2402-4 •
MA2403 •
MA2404-12 •
MA2405-34 •
MA2405-40 •
MA2405-54 •
MA2405-62 •
MA2406-20 •
Mounting
thread •

Page 7
System Design, Connection Options
confocalDT 2421 / 2422
Screw Terminals
Pin Description Notes
U/I out
GND
Shield
Analog Out
U/I out
Voltage output
0 ... 5 V; 0 ... 10 V;
Riapprox. 50 Ohm; 5.5 V / 10.9 V in the event of an
error, outside of measuring range
Current output 4 ... 20 mA; RL ≤ 500 Ohm; 23.7 mA in the event of
an error, outside of measuring range
GND Ground analog output Electrically connected to supply
+Sync/Trig
-Sync/Trig
Input/output synchroni-
zation, input triggering
RS422 level (EIA422)
+ Sync/Trig
- Sync/Trig
Digital I/O
GND
Shield
TrigIn
GND
Error 1
GND
Shield
Error 2
GND
TrigIn Input triggering
TTL or HTL level
TTL: Low ≤ 0.8 V, High ≥ 2 V
HTL: Low ≤ 3 V, High ≥ 8 V
Error 1 / 2 Error outputs NPN, PNP or Push-Pull
Imax = 100 mA, UH max = 30 V
GND Reference ground All GND conductors are interconnected with one
another and to operating voltage ground.
24 VDC Operating voltage ± 15%, Imax < 1 A
24 VDC
GND
Shield
Power
GND Operating voltage
ground
GND is electrically connected to GND of switching
outputs, synchronization, analog and encoder input
Shield Shields for relevant output/input, plug housing
The plug-in screw terminals are designed for an optical fiber cross-section of 0.14 mm² to 1.5 mm².

Page 8
Controller LEDs
confocalDT 2421 / 2422
RS422
- Differential signals according to EIA-422, electrically isolated
from the supply voltage.
- Receiver Rx with 120 Ohm internal terminating resistor.
Terminate the transmitter input Tx on the evaluation unit (re-
ceiver) with 90 ... 120 Ohm.
Use a shielded cable with twisted wires.
Cable length less than 30 m.
Connect the ground connections.
iThe pin assignment for the 9-pin D-sub socket is not stan-
dardized.
Pin Name Signal
3 RX - Receiver -
2 RX + Receiver +
5 GND422 Ground RS422
9 TX + Transmitter +
1 TX - Transmitter -
Housing Shield Cable shield
Pin assignment for 9-pin D-Sub socket (RS422)
Controller LEDs
Power on Green Operating voltage present
Status
Off No error
Flashing red Error during processing
If the EtherCAT interface is active, refer to the EtherCAT guidelines for the meaning of the LEDs.
Intensity
Sensor 1/2
Flashing red Dark signal acquisition in progress
Red Signal saturated
Yellow Signal too low
Green Signal OK
Range
Sensor 1/2
Flashing red Dark signal acquisition in progress
Red No target present, outside of measuring range
Yellow Target close to mid of measuring range
Green Target within the measuring range

Page 9
Controller LEDs
confocalDT 2421 / 2422
Multifunction Button
The Multifunction button on the controller is assigned multiple functions. As standard, the button is assigned the
dark reference function.
Multifunction
Function 1
Function 2
Dark reference Starts the dark reference for sensor 1 or sensor 2
Mastering, Reset Mastering Starts or stops a master measurement of the selected signals
LED Switches the light source for sensor 1 or sensor 2 on/off
The functions can be assigned to the individual time slots. All time intervals are indicated by the LEDs flashing/lighting
up.
Dark reference
LED
Mastering
Function 1
2 sec05 sec 10 sec 15 sec
Function 2
Key lock
x min Time
Factory
setting
Multifunction Button Actuation Time
As standard, the Multifunction button has a lock that is activated 5 min after the controller is switched on.
Start of Measuring Range
An offset distance (SMR) between each sensor and the target must be kept.
Sensor SMR Target
Start of measuring range (SMR), the shortest distance
between the front surface of the sensor and the target.

Page 10
Initial Operation
confocalDT 2421 / 2422
Initial Operation
iThe measuring system is ready to use approx. 10 s
after the controller is switched on.
To ensure precise measurements, let the measu-
ring system warm up for approx. 30 minutes.
The controller is shipped with the factory-set IP address
169.254.168.150.
You can query the IP addresses of the controllers that
are connected to a PC or network by using the sen-
sorTOOL.exe program. You can find this program on-
line at https://www.micro-epsilon.de/download/software/
sensorTOOL.exe.
Launch the sensorTOOL and click the button.
Select the controller from the list.
Click the Open Website button to connect the cont-
roller to your default browser.
The start screen of the controller software should now be
displayed in the web browser. You can configure the soft-
ware using the web pages or ASCII commands integrated
in the controller.
Selecting the Sensor
Go to the Settings > Sensor menu.
Select the connec-
ted sensor for the
relevant channel. Pay
attention to type and
serial number.
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels MICRO-EPSILON Contrôleurs

MICRO-EPSILON
MICRO-EPSILON CSP2008 Manuel utilisateur

MICRO-EPSILON
MICRO-EPSILON colorCONTROL MFA-5 Manuel utilisateur

MICRO-EPSILON
MICRO-EPSILON scanCONTROL 3000 Manuel utilisateur

MICRO-EPSILON
MICRO-EPSILON MSC7401 Manuel utilisateur

MICRO-EPSILON
MICRO-EPSILON capaNCDT 6110 Guide d'installation

MICRO-EPSILON
MICRO-EPSILON C-Box/2A Manuel utilisateur

MICRO-EPSILON
MICRO-EPSILON MSC7401 Manuel utilisateur

MICRO-EPSILON
MICRO-EPSILON C-Box/2A Manuel utilisateur