A 1398 PQA Iron Current Clamp Technical specifications
9
7 Technical specifications
Nominal current (INom)...................................10 A
Nominal current range ..................................5 % INom … 200 % INom
Maximal current (IMax) ...................................20 A
Crest factor @ Nominal current....................4,0
Peak current ..................................................40 A
Bandwidth .....................................................40 Hz …400 Hz
Uncertainty....................................................±(0,5 % of reading ±10 mA)
Phase Error ....................................................±≤0,45°(50 –60 Hz)
External fields................................................30 A/m (No influence)
Continuity of measurements.........................20 A (continuous)
30 A (40 min / 20 min intermitted)
Dimensions & Mechanical data:
Current sensor type.......................................D
Length of connection cable ...........................1,2 m
Jaw opening...................................................13 mm
Maximum conductor sizes.............................fi < 13 mm
Length of connection cable ...........................1,2 m
Dimensions (W x H x L)..................................27 mm x 52 mm x 170 mm
Weight ..........................................................340 g
Safety specification:
Over-voltage category...................................No CAT, (can be used on insulated conductors in 300 V CAT II)
Pollution degree ............................................2
Degree of protection.....................................IP 40
EMC:
Emission.........................................................Class B
Immunity .......................................................Portable equipment
Environment conditions:
Working temperature range .........................-10 °C … 50 °C
Storage temperature range...........................-20 °C … 60 °C
Humidity range..............................................0 %RH …80 %RH
Reference temperature range.......................25 C ± 5 C @ 40 %RH …60 %RH
Altitude..........................................................up to 2000 m
Operation ......................................................Indoor use
Substitute Electric Model for A 1398 PQA Iron Current Clamp
Equivalent circuit diagram for current clamp measurement: