Melco S100 Manuel utilisateur

English
Deutsch
Français

Warning
This equipment is not waterproof. To prevent fire or electric hazards, do
not place any containers filled with liquid near this equipment (such as a
vase or flower pot) or expose it to dripping, splashing, rain or moisture.
Warning
To prevent fire hazards, do not place any naked flame sources (such as a
lighted candle) on or near the equipment.
Warning
This is a class A product. In a domestic environment this product may
cause radio interference, in which case the user may be required to take
adequate measures.
This product may cause interference if used in residential areas.
Such use must be avoided unless the user takes special measures to
reduce electromagnetic emissions to prevent interference to the reception
of radio and television broadcasts.
Diagrams ................................................................................................................................................................... 1
Power On .................................................................................................................................................................. 2
Available Devices and Ports ............................................................................................................ 3
Specifications...................................................................................................................................................... 4
Additional Support and Service .................................................................................................. 5
Contents
Warning
Slots and openings in the cabinet are provided for ventilation to ensure
reliable operation of the product, and to protect it from overheating. To
prevent fire hazards, the openings should never be blocked or covered
with items (such as newspapers, table-cloths, curtains) and never operate
the equipment on thick carpeting or a bed.
Caution
This product becomes warm, so be careful not to touch it to avoid hazards.
Operating Environment
Operating environment temperature and humidity: +5°C to +35°C (+41°F to
+95°F); less than 80% RH (cooling vents not blocked)
Do not install this unit in a poorly ventilated area, or in locations exposed to
high humidity or direct sunlight (or strong artificial light).
English

1
Diagrams
Buttons and Ports
1Power/Diag LED
On (red): The network switch is starting up.
Start up will take about 70 seconds.
On (light blue): Power is on.
3Link/Act LED
On (green): Connection established.
4LED Off Switch
Press this switch to turn off the link/act LED.
Leaving the link/act LED on may affect the quality of sound. We
recommend turning off the link/act LED for typical music playback.
5LAN Ports
Ports 1–4 support 100 Mbps full duplex.
Ports 5–8 support 100 Mbps and 1000 Mbps auto negotiation.
6SFP Ports
The network switch will transmit data at 1000 Mbps using these two ports.
These ports support 100 Mbps and 1000 Mbps auto negotiation.
Note: LAN port 8 and SFP port 8 is a combo port pair. When both ports are
connected to devices at the same time, LAN port 8 will be
automatically disabled.
2DC Power Connector
1 2 6
3 4
5
English

2
Power On
English

3
Available Devices and Ports English
NAS
Network Audio Player
Available as a player.
Wireless RouterComputer
Available for saving or
playing music files.
Recommended Connections:
Network Audio Player (Renderer, Streamer) Ports 1–4
Music Server, Wireless Router, or Other Network Devices Ports 5–9
Melco N1/N10/N100 as USB-DAC Player Ports 1–4
Melco N1/N10/N100* as Music Server for Network Audio Player Ports 5–9
*Use the LAN port instead of the PLAYER port.
Ports 1–4 are full duplex; ports 5–9 are auto
negotiation.
If the Network Audio Player is not compatible
with full duplex ports and playback is not stable,
please connect the Network Audio Player
using ports 5–9 instead.

4
*Excluding protruding parts
Standards
Compliance
Data Transfer
Rates
Number of
LAN Ports
Number of
SFP Ports
Compatible
Cables
Transmission
Distance
IEEE 802.3ab (1000BASE-T)
IEEE 802.3u (100BASE-TX)
LAN Ports 1–4: 100 Mbps
LAN Ports 5–8: 100/1000 Mbps
SFP Ports 8, 9: 100/1000 Mbps
8
2
1000BASE-T:
four-pair category 5e or higher
UTP/STP cable
100BASE-TX:
two-pair category 5 or higher
UTP/STP cable
Max. 100 m
Connector
Dimensions*
(W × H × D)
Weight
Power Supply
Power
Consumption
(AC Adapter)
RJ-45 8-pin
215 × 61 × 270 mm;
8.5 × 2.4 × 10.6 in.
Approx. 2.5 kg; 5.5 lbs
AC Input:
100–240 V, 50/60 Hz (max. 12 W)
DC Input:
12 V, 1 A
Max. DC 12 V, 4 A
Asian Power Devices Inc. DA-48T12
Specifications
English

5
If you need help or repair services, please send us an email by referring to our website below or call the vendor
from whom you purchased the product.
You may also refer to our website for firmware update information.
https://www.melco-audio.com/support/
Additional Support and Service English

Warnung
Dieses Gerät ist nicht wasserdicht. Um eine Brandgefahr oder einen
elektrischen Schlag zu vermeiden, stellen Sie keine mit Flüssigkeit
gefüllten Behälter in der Nähe dieses Geräts (z.B. Vase oder Blumentopf)
und setzen Sie das Gerät nicht Tropfen, Spritzern, Regen oder
Feuchtigkeit aus.
Warnung
Verwenden Sie keine offene Flamme auf oder in der Nähe des Geräts (z.B.
eine brennende Kerze), um Brandgefahren zu vermeiden.
Warnung
Dies ist ein Produkt der KlasseA. In einer häuslichen Umgebung kann
dieses Produkt Funkstörungen verursachen. Um diese zu beheben,
müssen ggf. entsprechende Maßnahmen ergriffen werden.
Bei einer Nutzung in Wohngebieten können bei diesem Produkt Störungen
auftreten.
Eine solche Nutzung soll vermieden werden, außer der Nutzer ergreift
bestimmte Maßnahmen, um elektromagnetische Strahlung zu reduzieren
und Störungen der Radio- und Fernsehübertragung zu vermeiden.
Diagramme............................................................................................................................................................. 7
Einschalten ............................................................................................................................................................. 8
Verfügbare Geräte und Anschlüsse ...................................................................................... 9
Technische Daten ......................................................................................................................................... 10
Zusätzliche Support und Service .............................................................................................. 11
Inhalt
Warnung
Spalte und Öffnungen im Gehäuse sind für die Belüftung vorgesehen, um
einen zuverlässigen Betrieb des Produkts zu gewährleisten und es vor
Überhitzung zu schützen. Um Brandgefahren zu vermeiden, sollten die
Öffnungen niemals durch Gegenstände (z.B. Zeitungen, Tischdecken,
Vorhänge) blockiert oder abgedeckt sein oder das Gerät auf einem dicken
Teppich oder einem Bett betrieben werden.
Vorsicht
Das Produkt wird warm. Sie sollten daher darauf achten, es nicht zu
berühren, um Gefahren zu vermeiden.
Betriebsumgebung
Temperatur der Betriebsumgebung und Luftfeuchte: +5°C bis +35°C (+41
°F bis +95°F); unter 80% rel. Feuchtigkeit (RH) (Lüftungsschlitze nicht
blockiert)
Installieren Sie das Gerät nicht in schlecht belüfteten Räumen oder an
Orten, die hoher Luftfeuchtigkeit oder direktem Sonnenlicht (oder starkem
Kunstlicht) ausgesetzt sind.
Deutsch

7
Diagramme
Tasten und Anschlüsse
1Power/Diag-LED
Ein (rot): Der Netzwerk-Switch wird gestartet.
Der Start dauert ca. 70Sekunden.
Ein (hellblau): Eingeschaltet.
3Link/Act-LED
Ein (grün): Verbindung hergestellt.
4LED-Aus-Schalter
Drücken Sie diesen Schalter, um die Link/Act-LED auszuschalten.
Wenn Sie die Link/Act-LED eingeschaltet lassen, kann dies die
Klangqualität beeinträchtigen. Wir empfehlen, die Link/Act-LED für
die typische Musikwiedergabe auszuschalten.
5LAN-Anschlüsse
Anschlüsse1–4 unterstützen 100Mbit/s Vollduplex.
Anschlüsse5–8 unterstützen 100MBit/s und 1000MBit/s Auto-Negotiation.
6SFP-Anschlüsse
Der Netzwerk-Switch überträgt Daten mit 1000MBit/s über diese
beiden Anschlüsse.
Diese Anschlüsse unterstützen 100MBit/s und 1000MBit/s Auto-Negotiation.
Hinweis: LAN-Anschluss8 und SFP-Anschluss8 sind ein kombiniertes
Anschlusspaar. Wenn beide Anschlüsse gleichzeitig mit Geräten
verbunden sind, wird LAN-Anschluss8 automatisch deaktiviert.
2DC-Netzanschluss
1 2 6
3 4
5
Deutsch

8
Einschalten
Deutsch
Table des matières
Langues :
Autres manuels Melco Changer