VII Troubleshooting:
Problem Cause Solution
Little to no disinfectant flow 1. Nozzle clogged
2. Suction tube clogged
3. Clogged filter
4. Battery is out of power
1. Clean
2. Clean
3. Remove disinfectant container
and clean filter
4. Charge battery
Leaking disinfectant 1. Nozzle loose
2. Nozzle worn
3. Nozzle seal worn
4. Material build-up on nozzle
5. Container is loose
1. Tighten
2. Replace
3. Replace
4. Clean
5. Tighten the disinfectant container
The Electrostatic indicator does not light up
1. The bracelet is not securely connected.
2. The bracelet connector is dirty or blocked.
3. The battery is not charge enough.
1. Secure the bracelet to the connector.
2. Clean the connector and reattach the
bracelet.
3. Charge the battery.
Atomization is too coarse 1. Nozzle clogged 1.Clean
Spray jet pulsates 1. Disinfectant in container running out. 1.Refill
Pattern runs or drips 1. Applying too much disinfectant 1. Increase movement of sprayer
Not enough disinfectant coverage 1. Sprayer too far from spray object 1. Reduce distance
Pattern is very light and splotchy 1. Moving the sprayer too fast 1. Decrease movement of sprayer
Large wet spots 1. Sprayer too close to surface 1. Move sprayer away from surface
VIII Warning!
Never point the sprayer at another person or animal. In the event of an injury,
seek immediate medical attention.
Do not use any other solution other than MedPro Defense disinfectants approved for use in
commercial sprayers.
You must clean the sprayer thoroughly after each use.
Do not use a sprayer that is damaged in any way.
Do not alter the sprayer by adding or removing parts.