MadMan EMS-3 Manuel utilisateur

Introduction
The EMS-3 is a multifunction engine information display and early warning engine monitoring system. It has been
specifically designed to monitor crucial vehicle information, and in the event of any engine irregularities, it will alert the
driver by means of a visual and audible alarm.
ith its array of advanced features, the EMS-3 is an indispensable unit for the discerning vehicle owner. Costly
maintenance bills can easily be avoided by the prevention of major engine problems before they occur.
Madman EMS-3
Universal Engine Monitoring System
Operating Manual – English 1.0

Madman EMS-3 Operating Manual Page 2
1 Features
Large 1.8” high resolution 160x128, sunlight readable, wide viewing angle, 1000 cd/m2 T T LCD display
Battery voltage display, the EMS-3 can measure voltages up to 30V (Can be used in 12V and 2 V vehicles)
and contains a programmable low/high voltage alarm to automatically catch alternator failures, drive belt
failures and bad batteries
Hour meter display to determine actual engine running time with 1/10 hour resolution
Built in service interval reminder based on vehicle ignition on time
EGT (Exhaust gas temperature) can be displayed in degrees Celsius or degrees Fahrenheit from -100ºC
to 1200ºC (-1 8ºF to 2192ºF) and contains a user settable high alarm.
Includes an EGT trend graph display
Includes linearization of K or J Type thermocouple probes and is cold junction compensated for greater
accuracy
x Universal analog input channels that can be configured for pressure or temperature.
Pressure sender measurement with user settable high and low alarm. Pressure sender inputs can be
from a Fuel, Oil, Manifold, Turbo Boost or an Auxiliary pressure sender.
Temperature measurement with user settable high and low alarm. Temperature sender inputs can be from
an Oil, Coolant or an Auxiliary temperature sender.
Oil Pressure warning alarm from oil pressure senders that have a switch output
Coolant level absence/presence detection by the means of AC signal probe excitation. The EMS-3 can
use inexpensive probes such as stainless steel screws to determine the coolant level. The EMS-3 can also
be used with float level type sensors. The Coolant level detection circuit also has a programmable switch
time to prevent false alarm messages when driving over rough terrain
Fan control output for on/off temperature control
All senders linearized for additional accuracy
Each sensor display can be individually enabled or disabled
Includes an external audible alarm output (The sound can be turned on/off, for example game viewing)
Dual external alarm outputs
Ambient light sensor for automatic or manual backlight control
On-board voltage reversal and over voltage protection for harsh vehicle environments
Standard 2” (52mm) circular enclosure
SMPS (Switch mode power supply) for use in both 12V and 2 V vehicles
Maximum values of all readings are recorded
Easy to use menu system for user parameter setup
Field upgradable firmware via the RS232 interface
1 year limited warranty

Madman EMS-3 Operating Manual Page 3
2 Layout
3 Main Displays
The main display screens can be viewed by pressing the up and down buttons in the normal display mode.
Sunlight readable color
graphic display
Menu Button:
Press the menu button during the normal display
screens to access the menu system.
Up Button:
Menu System: Up button / Increment
Normal: Scroll through main display
screens
2” (52mm) enclosure.
Harness connects to power
and senders
Enter Button:
Enter button in the menu system
Down Button:
Menu System: Down button / Decrement
Normal: Scroll through main display
screens
Ambient light sensor for
automatic backlight control.

Madman EMS-3 Operating Manual Page
3.1 EGT (Exhaust Gas Temperature) / Pyrometer
Few things will damage or kill a diesel engine like excessive exhaust gas temperatures, yet the EGT gauges are not
standard equipment fitted by the diesel engine manufacturers and are only available as an after market add on unit.
The EMS-3 can alert the driver of any situations where the EGT gets too high which could cause irreparable engine and
or turbo charger damage. The EGT can be affected by a too rich air/fuel mixture or an air intake problem. Air intake
problems could include a blocked/partially blocked air intake, a dirty air cleaner, high water temperatures etc. The EMS- 3
EGT gauge could also save on fuel costs as the EGT is directly related to the air/fuel mixture.
The EGT probe can be installed on the exhaust manifold or immediately after the turbo. It is recommended to install the
EGT probe before the turbo as temperature differences of up to 200ºC (392ºF) between the inlet and outlet of the turbo
has been measured under heavy loads.
Under normal driving conditions the EGT may vary between 250ºC (482ºF) and 650ºC (1202ºF). For most vehicles the
alarm limit should be set to 720ºC (1328ºF). Please be aware that pushing the engine hard or driving up a steep hill, could
cause the exhaust gas to exceed this temperature. If you have prolonged high EGT then it is recommended to
immediately have it checked out by a qualified mechanic.
Madman custom built thermocouple EGT probes are specifically designed for automotive use. The Madman EGT probes
can handle temperatures up to 1300ºC (2372ºF).
The EMS-3 can use K-Type or J-Type thermocouples to display the EGT temperature. The EMS-3 contains precision
instrumentation electronic circuitry to amplify and linearize the thermocouple sensor. The EMS-3 also has built in cold
junction compensation to make the EGT reading as accurate as possible.
3.2 Battery Volts
The EMS-3 can measure the vehicle's battery voltage in the range of 8V to 30Vdc and has built in over-voltage and
reverse voltage protection. The EMS-3 contains a programmable low/high voltage alarm to automatically catch alternator
failures, drive belt failures and bad batteries.
3.3 Pressure Display
The EMS-3 uses standard automotive pressure senders to display the pressure. The EMS-3 supports 2, 5 and 10 Bar
VDO senders, SENDO MPS 2, 5, 7, and 10 bar senders, 0.5-4.5V senders, 4-20mA pressure senders or a custom user
definable pressure sender curve.
3. Oil Pressure Switch Message
The EMS-3 can also be used to display a warning message from a switch type oil pressure sender. These senders can be
of a NO (Normally Open) or a NC (Normally Closed) type sender. The oil pressure switch uses the analog input
channel.
This message is displayed when there is an oil pressure alarm from the switch (NO/NC)
on the oil pressure sender.

Madman EMS-3 Operating Manual Page 5
3.5 Temperature Display
The EMS-3 uses standard automotive temperature senders to display the temperature. The EMS-3 also contains fail safe
temperature inputs to alert the user when the sender has been disconnected or faulty. The EMS-3 supports 120 and 150
VDO senders, a precision temperature sender, Echlin TS920SA or a custom user definable temperature sender curve.
3.6 Coolant Level Detector
The coolant level detector is an engine coolant level early warning system. It uses an AC signal probe excitation to
accurately determine the absence/presence of coolant level. The coolant level detector can use inexpensive probes such
as stainless steel screws to determine the coolant level. It also features a fail safe input circuit. The coolant level detector
can also be used with float level type sensors (These senders must be of a normally open type). The coolant level switch
must connect to the vehicles negative supply terminal when the coolant level is at an acceptable level.
The coolant level detector has a programmable switch time. This means that the level alarm from the coolant level switch
must be activated for at least the programmed time before an alarm is activated. This prevents false alarm messages
when driving over rough terrain etc. The EMS-3 also has a programmable coolant level threshold which allows the user to
fine tune the trigger point.
This message is displayed when there is a coolant level problem.
3.7 Service Timer Expired Message
This timer is set in engine hours and it will count down to zero. The purpose of this function is to assist you in determining
remaining hours until maintenance will be required.
A maximum of 9999 hours can be entered as a service interval. An alarm message will
be displayed and the appropriate alarm output will be activated (if enabled).
3.8 Hour meter
The hour meter is a useful instrument to display actual engine running time for routine maintenance. The hour meter is
displayed as hours and fractional minutes in 1/10 of an hour resolution (increments every 6 minutes). The hour meter can
be reset to zero in the “TIMERS SETUP” menu. The hour meter updates its internal minute counter every minute. If the
unit is turned on and off for a period of less then a minute, then the hour meter will not increment its internal registers.
The hour meter can be triggered by an ignition on signal or by a rise in battery voltage which signals that the engine is in
fact running.

Madman EMS-3 Operating Manual Page 6
Menu System
Press the menu button during the normal display mode to enter the menu system. Use the Up / Down keys to navigate
through the menu system.
.1 Exiting the menu system
Press the Menu button to exit the menu system when the “EXIT” soft key is shown. All changes made during navigation
of the menu system will be saved in non-volatile memory upon exiting. The instrument will not save any changes if you
remove power before exiting the menu system.

Madman EMS-3 Operating Manual Page 7
.2 EGT (Exhaust Gas Temperature Setup)
Display:
Select "ON" to enable the EGT display.
Label:
Enter a label to suit your EGT Channel so you can easily identify it.
Display Max:
Select the maximum temperature that you want the EGT bargraph to show. This can give you increased display
resolution.
Display Min:
Select the minimum temperature that you want the EGT bargraph to show. This can give you increased display resolution.
High Alarm:
This enables or disables the EGT high alarm.
High Alarm:
Enter the temperature threshold for when the high alarm must be activated. Any temperature above this value will activate
the alarm.
High Caution:
Enter the temperature value for the high caution.
Alarm:
Select which output the alarm must activate.

Madman EMS-3 Operating Manual Page 8
Probe:
Select if you are using a K-type or J-type thermocouple probe.
Unit:
Select whether you want the temperature to be displayed in degrees Celsius (ºC) or degrees Fahrenheit (ºF).

Madman EMS-3 Operating Manual Page 9
.3 Analog CH1 to CH Setup
The 4 analog channels are universal analog input channels that can be used for pressure, temperature etc.
Only “CHANNEL 1” Setup is shown below, follow the same steps for Channel 2, 3 &
.3.1 Pressure Setup
Mode:
Select the function for the analog channel. Options are “PRESSURE”, “TEMP” or “OFF”.
Type:
Select if you are using a resistive, voltage or current pressure sender.
If the “R SISTIV ” pressure sender is selected
In most cases resistive sensors require a biasing voltage to work properly. Inside the EMS3
unit is a small block of DIP switches, The switch associated with the required channel must be
in the ON position to enable the sensor to work correctly. By default, CH1 + CH2 are ON and
CH3 + CH are off. Failure to set the DIP switch will not cause damage but will cause false
readings.

Madman EMS-3 Operating Manual Page 10
Sender:
Select what type of resistive pressure sender you are using. Select “VDO” for VDO / resistive senders, “USER” for a
custom sender.
Model:
Select which VDO pressure sender you are using. A selection between a VDO 2, 5 or 10 Bar can be selected.
If the “VOLTAG ” pressure sender is selected
Sender:
Select the type of voltage sender you are using. Select “SENDO” for SENDO senders, "0.5-4.5V" for voltage senders, or
“USER” for a custom voltage sender.
Model:
Select which SENDO pressure sender you are using. A selection between a MPS 2, 5, 7 or 10 Bar can be selected.
If the “CURR NT” pressure sender is selected
Sender:
Select the type of current sender you are using. Select “4-20mA” for 4-20mA sender or “USER” for a custom 4-20mA
sender.
Pressure @ 4mA:
Enter the pressure specified at 4mA output.
Pressure @ 20mA:
Enter the pressure specified at 20mA output.
Menu options for all sender types
If the “US R" pressure sender is selected
Calibrate Sender:
If the sender type is set to “USER”, then use this menu option to calibrate your pressure sender. See section 4.3.3 for
more information.
Label:
Enter a label to suit your pressure channel so you can identify it easily.
Unit:
Select whether you want to display the pressure in Bar or psi.
Display Max:
Select the maximum pressure that you want the bargraph to show. This can give you increased display resolution.
Display Min:
Select the minimum pressure that you want the bargraph to show. This can give you increased display resolution.
High Alarm:
This enables or disables the pressure high alarm.
Table des matières
Autres manuels MadMan Instrument de mesure
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur












