Product warranty
The BPD17 pH / Redox Monitor has a warranty against defects in materials and
workmanship for three years from the date of shipment. During this period LTH will, at its
own discretion, either repair or replace products that prove to be defective. The associated
software is provided ‘as is’ without warranty.
Limitation of warranty
The foregoing warranty does not cover damage caused by accidental misuse, abuse,
neglect, misapplication or modification.
No warranty of fitness for a particular purpose is offered. The user assumes the entire risk of
using the product. Any liability of LTH is limited exclusively to the replacement of defective
materials or workmanship.
Disclaimer
LTH Electronics Ltd reserves the right to make changes to this manual or the instrument
without notice, as part of our policy of continued developments and improvements.
All care has been taken to ensure accuracy of information contained in this manual.
However, we cannot accept responsibility for any errors or damages resulting from errors
or inaccuracies of information herein.
Copyright and trademarks
All rights reserved. Translations, reprinting or copying by any means of this manual,
complete or in part or in any different form requires our explicit approval.
BPD17 is a trademark of LTH Electronics Ltd
Second edition: May 2018
LTH Electronics Ltd
Chaul End Lane
Luton Telephone : +44 (0)1582 593693
Bedfordshire Fax : +44 (0)1582 598036
England Web : www.lth.co.uk

Preface
- 2 - BPD17 pH / Redox Monitor
Operating Guide
Manufacturing Standards
Electromagnetic compatibility
This instrument has been designed to comply with the standards and regulations set down
by the European EMC Directive 2014/30/EU using BS EN 61326-1: 2013
Safety
This instrument has been designed to comply with the standards and regulations set down
by the European Low Voltage Directive 2014/35/EU using BS EN 61010-1: 2010
Restriction of Hazardous Substances
This instrument has been produced to comply with the standards and regulations set down
by the European Restriction of Hazardous Substances Directive 2011/65/EU using BS EN
50581: 2012
Quality
This instrument has been manufactured under the following quality standard:
ISO 9001:2008. Certificate No: FM 13843
Note: The standards referred to in the design and construction of LTH products are those
prevailing at the time of product launch. As the standards are altered from time to time, we
reserve the right to include design modifications that are deemed necessary to comply
with the new or revised regulations.
Disposal
As per directive 2012/19/EU, please observe the applicable local or national regulations
concerning the disposal of waste electrical and electronic equipment.

Preface
BPD17 pH / Redox Monitor
Operating Guide - 3 -
Declaration of Conformity

Preface
- 4 - BPD17 pH / Redox Monitor
Operating Guide
Blank

Contents
BPD17 pH / Redox Monitor
Operating Guide - 5 -
Contents
Preface....................................................................................................................................1
Contents ................................................................................................................................5
Introduction .........................................................................................................................7
pH / Redox (ORP) Input Specification .........................................................................8
Installation – Safety & EMC .......................................................................................... 11
Noise suppression........................................................................................................... 12
Enclosure ............................................................................................................................ 13
Surface-Mounting..................................................................................................... 14
Panel-Mounting......................................................................................................... 15
Pipe-Mounting........................................................................................................... 16
Terminal Operation.................................................................................................. 17
Supply Voltage Connections ................................................................................ 17
Relay Connections.................................................................................................... 18
Current Output Connections................................................................................ 18
Digital Inputs .............................................................................................................. 19
MicroSD Card Interface........................................................................................... 19
Installation and Choice of pH / Redox Electrodes ............................................... 20
Care and Maintenance of pH / Redox Electrodes.......................................... 20
BPD17 pH / Redox Input Connection Details ................................................. 22
Temperature Sensor Connections...................................................................... 25
Extension Cable Connections............................................................................... 26
User Interface.................................................................................................................... 27
The Front Screen....................................................................................................... 27
Security Code Access............................................................................................... 28
pH / Redox (ORP) Input Setup..................................................................................... 29
Channel Menu............................................................................................................ 29
Units............................................................................................................................... 29
Temperature Compensation mode ................................................................... 30
Input Filtering (Averaging).................................................................................... 31
Calibration.......................................................................................................................... 32
Calibration Menu ...................................................................................................... 34
Sensor Condition ...................................................................................................... 37

Contents
- 6 - BPD17 pH / Redox Monitor
Operating Guide
Front Screen Calibration Access.......................................................................... 38
Calibration Reminder .............................................................................................. 38
Custom Buffer Entry................................................................................................. 39
Auto pH Sensor Calibration................................................................................... 41
Manual pH Sensor Calibration ............................................................................. 43
Buffer Solutions ......................................................................................................... 44
Setpoints............................................................................................................................. 45
Trigger........................................................................................................................... 45
Hysteresis..................................................................................................................... 48
Setpoint Dose Alarm................................................................................................ 49
Setpoint Cleaning Mode ........................................................................................ 51
0/4-20mA Output ............................................................................................................ 53
Output Mode.............................................................................................................. 53
On Error ........................................................................................................................ 54
Calibration................................................................................................................... 54
Digital Inputs..................................................................................................................... 56
Polarity.......................................................................................................................... 57
Configuration.................................................................................................................... 58
Main Menu .................................................................................................................. 58
Unit Flash On Error ................................................................................................... 59
Set Display Contrast................................................................................................. 59
Software Version ....................................................................................................... 59
Serial Number ............................................................................................................ 60
Contact Information ................................................................................................ 60
Update Software.............................................................................................................. 61
Save, Restore & Reset ..................................................................................................... 62
Service ................................................................................................................................. 64
Service Alarm.............................................................................................................. 64
Appendix A - Temperature Data................................................................................ 65
Appendix B - Error Messages....................................................................................... 66
Fault Finding ..................................................................................................................... 68
Problems with Cables and Connectors............................................................. 69
Guarantee and Service .................................................................................................. 70

Introduction
BPD17 pH / Redox Monitor
Operating Guide - 7 -
Introduction
The BPD17 is a microprocessor controlled pH and Redox (ORP) measurement instrument
that can be used with a wide range of Single ended or differential electrodes to measure
and control a broad spectrum of solution pH or Redox. To achieve this, the instrument
utilises a multifunction LCD to display the primary reading and temperature, show
operational status and to provide an intuitive user interface.
As standard the instrument is a simple to install IP66 rated Wall-mount instrument,
however with the addition of a suitable mounting kit it can either be installed as a Panel-
mount or Pipe-mount instrument.
The instrument has two on-board volt-free normally-open relays with adjustable setpoint
value and hysteresis. Either one can be set to activate if the process variable is above or
below the setpoint allowing the instrument to be used in a variety of dosing or control
applications. Additional setpoint functions include delayed activation, dose alarm timer
and scheduled cleaning, whilst the status of the relays can be seen via the main screen of
the instrument.
Additionally, the instrument features one industry standard, isolated, 0/4-20mA current
output that features adjustable scaling, selectable on-error states and loop fault detection,
allowing the instrument to transmit the primary reading for remote monitoring purposes.
Also fitted are two contact inputs which allow the instrument to be remotely set to an
offline state that forces the relays to deactivate and the current output to a pre-defined
state.
Depending upon version purchased the instrument is powered by either 85-265V AC or 12-
30V DC.

Specification
- 8 - BPD17 pH / Redox Monitor
Operating Guide
pH / Redox (ORP) Input Specification
Measurement Input Single ended or differential with solution ground.
pH
Separate glass and reference electrode pair.
Combination electrode.
Redox (ORP)
Separate glass and reference electrode pair.
Combination electrode.
Other manufacturer’s sensors can be accommodated.
Connection Cable Up to 30 meters (no preamp required)
LTH type 54E or LN10 cable
Ranges of Measurement 0.00 to 14.00 pH
-1999mV to +1999mV.
Accuracy ± 0.05 pH.
± 3mV.
Linearity ± 0.1% of range.
Repeatability ± 0.1% of range.
Operator Adjustment
Slope Offset
pH
60-120% 3 to 11pH
Redox
NA -400mV to +400mV
Calibration Methods Automatic 4pH / 9pH Buffer Calibration, Alternative buffers
supported by user entry into instrument.
Manual Slope and Offset Adjustment.
Both methods feature post-calibration electrode
condition indication
Custom Buffer
13 point 4pH / 9pH custom buffer entry pre-loaded with
standard LTH buffers, alternative buffers also supported by
user entry into instrument.
Sensor Input Filter
Adjustable filter that averages the sensor input over a
user selectable time (10sec – 5mins).
Temperature Sensor Pt1000 or PT100 RTD input. Up to 30 meters of cable.
Temperature sensor can be mounted in the sensor or
separately.
Range of Temperature
Measurement
-50 °C to +150 °C (-58 °F to +302 °F) for full specification.
Temperature Accuracy ± 0.5 °C (when using PT1000)
Table des matières
Autres manuels LTH Electronics Instrument de mesure
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur