LockStateConnect LS-60 Manuel utilisateur

PG 1
LS-60 Operation Guide
The LS-60 programmable communicating thermostat
operates via a high-quality, easy-to-use touch screen.
To program or adjust your LS-60, simply touch your
finger firmly to the screen. The screen will automatically
light up and you will hear a “beep.” Do not use a sharp
or metallic device; it will scratch the screen.
ENGLISH
Statement of use: 100% Compatible with all popular
residential HVAC systems; 24VAC single, two stage
conventional heating systems (gas/oil/electric), heat pumps,
single stage or with auxilliary heat (electric or fossil), zoned
forced air and zoned hot water (2 or 3 wire), millivolt systems
(with a 12-24 AC or DC source), one or two stage cooling, and
hybrid systems.
Save
Energy
button
Power Grid
status
indicator
top cover
Touch screen
Wire
terminals
Mode
button
Fan
button
MENU
butto
n
PROG
butto
Reset
button
HVAC
selections
switches
bottom
cover
DAY
F
LINK
RADIO
TARGET TEMP
1
COOL
AUTO
PM
n

PG 2
PG 2
Control Screens HOME Screen
Before you operate the /6 please get familiar with these basic control screens. All the /6
functions are accessed through these screens: HOME, MENU, PROGRAM and MANUAL. The /6
touch screen technology allows you to select (by touching) an item and change it using the +/- arrows
or the time arrows.
The HOME screen is displayed when
the unit is operating. Touching the
HOME icon on another screen
will always return you to this screen.
To set a Mode:
Press the mode button on the side.
The /6 will step through the
modes HEAT, OFF, and COOL in
order. The LCD shows what mode
you are in.
DAY
F
LINK
RADIO
TARGET TEMP
1
COOL
AUTO
PM
Thermostat
Mode
Time
of day Current Room
Temperature
Radio
indicator
Lock
status
Fan
status
Time
Slot
Target
Temperature
Day

PG 2PG 2
PG 3
MENU Screen The MENU screen is the gateway to many functions or settings of the
/6. It is displayed when you press the MENU button. [See page 10 for details]
Set Day
Touch this area to set
the day of the week.
Set Time
Touch this area to set
the time of day.
Left arrow goes back,
right arrow goes forward.
Calibration control
Use this to calibrate your
LCD display match to
another thermometer.
Set
o
C -
o
F
Touch this
to set temp
display units.
Lock Program
Touch for 5 sec
to lock or unlock.
Filter Timer
set
Touch and hold
5 sec to change.
Chirp set
Touch this to turn the
audible chirp on or off.
Temperature
Swing set
Differential to set
for 2nd Stage start.
Return
to
HOME
screen.
HVAC SETUP
Touch this in OFF mode to
�
configure the unit to work with
your HVAC system.
DIFF
SWING
FILTER
F
HVAC
SETUP
CALIBRATE

PG 4PG 4
PROGRAM Screen The stand alone PROGRAM screen sets the/6 control
for your home HVAC system with out a central controller. Press and hold PROG for 10 sec to access
it. After that it is displayed when you press the PROG button. [See page 8 for details]
PROGRAM
MORN
F
COPY DAY
HEAT
AM
Set Program Day
Touch this area to set the day of the week
you want to program.
Set Time Slot
Touch this area to set the
Time Slot you want to program.
Copy
Touch this area to copy
current day’s program
to the next day.
Return HOME
When programming is complete
touch this to run your program and
return to the HOME screen.
Set Program Time
Touch this area to set the
time of day you want each
time period to start.
Left arrow goes back,
right arrow goes forward.
[Touch and hold for fast set.]
Temp Up / Temp Down
Touch these to raise and
lower each Target Temp.
[Touch and hold for fast set.]

PG 4PG 4
PG 5
MANUAL Screen The Manual Screen control screen is where you can make
temporary changes to your /6’s operation. From the Full HOME screen, touch the main
temperature display to use this screen. [See page 13 for details]
F
HOLD
EMER
HOLIDAY
HEAT
Target
Temperature
Room
Temperature
Return HOME
Temp Up / Temp Down arrows
Touch these to raise and lower
the manual override Target Temp.
HOLIDAY
Touch this to invoke a
single program that repeats day
after day until you turn it off.
Manual Override Indicator
Shows TEMPORARY when
you have modified the Target Temperature
EMER heat for
HEAT PUMP systems.
TEMPORARY
HOLD Touch this area to operate the thermostat as
a manual thermostat. It will keep the temperature
you set until you change it or cancel HOLD.

PG 6
PG 6
Simple HOME Screen Make this the default HOME screen for your
/6 by holding the PROG button for 12 seconds. This Simple HOME screen gives you limited
access to the /6’s on screen display and no programming capability. It makes the /6 behave
like a simple one setting
thermostat.
The simple screen is useful
for people who do not want
a complex progam changing
their target temperatures each
day. By simply using the Save
Energy button these users can
conserve energy and preserve
their comfortable temperature
settings.
F
LINK
RADIO
TARGET TEMP
1
COOL
Thermostat
Mode
Current Room
Temperature
Radio
Indicator
Target
Temperature
Temp Up / Temp Down
Touch these to raise and lower the
Target Temp. [Touch and hold for fast set.]

PG 6
PG 6
PG 7
Initial Settings
Press MENU to to access the following commands (from HOME screen).
Set day of the week
Touch the Day of the week area to cycle through the days of the week to select the current day.
Set time of day
Touch the Time of Day arrows to move the time selection forward or backward until
it displays the current time. Touch and hold for faster setting.
Set oF-oC display
Touch the oF and it will toggle to oC.
Set audible chirp
Touch the musical note icon to select the chirp
or no chirp.
Return HOME by touching the home icon.
ForwardBackward

PG 8
PG 8
Auto-Run Program
The /6 comes pre-programmed with an EPA approved program. This program is recommended by
the EPA for energy efciency. We strongly recommend that you Auto-Run this program for one week,
and see if it works for you. If it does not t your needs you can always input a custom program.
To run the EPA program, set the mode switch to HEAT or COOL.
Press the MENU button and use the arrows by the time display to set the time.
Touch the DAY area and advance it to select the present day.
Touch HOME. The unit is now running the program.t
All Days 70
o
F 62
o
F 70
o
6
2
o
F
MORN
6:00am
HEAT DAY
8:00am
EVEN
6:00pm
NITE
10:00pm
All Days 78
o
F 85
o
F 78
o
F 82
o
F
MORN
6:00am
COOL DAY
8:00am
EVEN
6:00pm
NITE
10:00pm
EPA
TO CHANGE THE PROGRAM:
Make sure the /6 mode is set to either HEAT or COOL, then press the PROGRAM button. This
puts you at the PROGRAM screen [see page 4]. The programmed start time is displayed in the
upper left. The TIME SLOT icon indicates the active TIME SLOT in the default program [MORN, DAY,
EVEN, NITE]. The programmed Target Temperature is shown on main display.
The HEAT program and the COOL program are separate.

PG 8
PG 8
PG 9
PROGRAM cont.
Select the day you want to program.
The day of the week starts at SU - Sunday and can be advanced to the day you want to program.
Touch the day of the week area to cycle through the days of the week to the desired day.
Select the time slot (period) you want to program (MORN, DAY, EVEN, NITE).
Touch the time slot area to cycle through to the desired period.
Select the desired start time of that time slot.
Touch the time arrows to select the desired period’s starting time. Hold arrow down for fast time
scrolling.
Select the desired target temperature for that time slot.
Touch the +/- arrows to select the desired period’s temperature.
To COPY one day’s programming to the next day, touch COPY DAY once. The information for the
current day will be copied to the next day which will appear on the screen. Holding down COPY for
over 3 seconds will copy to all 7 days.
Touch to return to the Home screen.

PG 10
PG 10
MENU Screen Functions
Press MENU to bring up MENU screen.
TIME of DAY
Touch the left (down) or right (up) arrows next to the time display to set the current time (1 minute per
touch). Touch and hold the arrow for fast time set (15 minute jumps).
DAY of Week Touch DAY area to select present day.
SWING (HVAC cycling rate) This feature allows you to set the desired variance in temperature
between the /6 setting and the room temperature required before the heating or cooling system
will turn on—from 0.5° to 2.0° F (.25° to 1° C). For example, if SWING is set to 2.0° F and the LS-60
is set to 70°F Target Temperature, the heat cycle will start when room temperature drops to 68°F.
Similarly, the cooling system will start when the room temperature increases to 72°F. The HVAC then
runs and will shut off at the Target Temperature.
To set SWING:
Touch SWING.
Touch the left/right arrows to set the SWING from 0.5° to 2.0°F.
The HVAC will run more frequently at .5°F and less at 2°F. Default is 1°F.
Touch to return to the MENU screen.
Chirp set- Touch this to turn the audible chirp sound on or off.
Table des matières
Autres manuels LockStateConnect Thermostat
Manuels Thermostat populaires d'autres marques

EWELLY
EWELLY EW-181 Manuel utilisateur

Prolon
Prolon T1100 Instructions d'installation

Computherm
Computherm Q20 Manuel utilisateur

Heatmiser
Heatmiser neoStat Manuel utilisateur

Aube Technologies
Aube Technologies TH111GFCI-NP 240 VCA Manuel utilisateur

Mars