Control Method
Controler stores up to 10 groups of emission coding
The default is multichannel, setting of single channel is as same as multi channel
Maximum running time of motor is 5 minutes
UP/DOWN delay time of switch is 500ms
Power on the controller, all LED turn on for 1 second. In working condition, L1 is lit,
the power supply is working properly
Reset: Press K1, all LED turn on for 1 second and then turn off, reset successfully
Controller receives 2nd priority signal from the fire center, smoke sensor or gas
detector, L2 flashed at 5Hz frequency and the buzzer alarms until reset or restart
External manual switch is equivalent to the switch on the controller
Group Control
By default, L1 is lit, the rest LEDs are off as a group control status.
Press K2, L2 turns on, the windows open, L2 turns off after 5 seconds
Press K4, L4 turns on, the windows close, L4 turns off after 5 seconds
Press K3, L3 turns on, the motors stop, L3 turns off after 1 second
Single Channel Control
Press channel selection keys K5, K6, K7, K8, or K9, the corresponding LED lights,
channel selected
Press the channel selection button again or no operation on K2, K3 or K4 within 10
seconds, LED turns off, channel unselected
Within 10 seconds after selecting channel
Press K2, L2 turns on, the windows open, L2 turns off after 5 seconds
Press K4, L4 turns on, the windows close, L4 turns off after 5 seconds
Press K3, L3 turns on, the motors stop, L3 turns off after 1 second
In the process of opening/closing the current window, you can select another
channel(s) to drive the window
Cascaded Control
The controller can be used as a master controller, a slave controller or play a dual
role of master & slave controller at the same time.
As a master controller, connects to the motors or slave controllers to drive them
As a slave controller, input terminals SU and SD are connected to the output
terminals M+ and M- of the master controller to receive the instructions to drive
motors, or drive the motors independently
Play a dual role of master & slave controller, not only controlled by higher-level
controller, but also drive motors or lower-level controllers independently
No matter master, slave or both, it can process all the external signals such as
manual switch, remote and sensors.
Installation Note
Please observe the following provisions in accord with standard of effective power
The control panel must be installed by professional technician
Maximum output power of single channel controller MUST NOT exceed the total
rated power of the controller
Additive maximum output power of each single channel of double channel
controller MUST NOT exceed the total rated power of the controller
Additive maximum output power of each single channel of 5 channel controller
MUST NOT exceed the total rated power of the controller, and the maximum
output current of each channel MUST NOT exceed 10A
The main power supply must be cut off before installing wiring to ensure safe
operation
Be careful when installing actuators, avoiding the window closed accidentally
causing injuries to person
Do not disassemble the internal parts of the control panel, if unusual please
contact supplier
Do not use metal objects to touch or shade the antenna, avoid the interference of
receiving signals
Transmit distance: 50 meters without obstacle, 20 meters through wall
After the installation, ensure that the cables are not affected by tension