Leaptronix LA-100P Manuel utilisateur

LA-100P User’s Manul

1-1 Product Overview
1-2 Safety & Caution
1-3 Specifications and Characteristics of Product
1-4 Standard Accessories of LA Series
1-5 Optional Accessories
2-1 Inspection before Installation
2-2 Places for Placement
2-3 Specifications of Input Power Supply
2-4 Use of Standby Fuse
2-5 Connection of LA System
2-6 Switch Test
3-1 Instructions on Front Panel
3-2 Instructions on Side Interface
3-3 Instructions on Rear Panel
4-1 Quick View for Operations
4-2 starting up System Power Supply
4-3 Setting Channel Quantity and Titles
4-4 Adjusting the level of Channels
4-5 Setting the Trigger State of Channels
4-6 Executing Trigger Signal Capture
Chapter One: Product Instructions....................01
Chapter Two: Installation of Instrument...........06
Chapter Three: Instructions on Instrument Panel...10
Chapter Four: Operation Instructions................25
LA-100P User’s Manul
Contents

LA-100P User’s Manul
Contents
4-7 Observing the Wave Form of Capture Signal
4-8 Save and Load of Wave Form
4-9 Power off LA System
5-1 Installation of PC-LINK
5-2 Operations of PC-LINK
5-3. Observing Signal Wave Form
5-4. Exit Operations:
6-1 Capture of Simple
6-2 Capture of Specific Events
6-3 Details of Signal Analysis
6-4 Setup of Advance or Delay Trigger
6-5 Save of Test Results
6-6 State Test
6-7 Remote Control
7-1 Calibration Manner
8-1 Maintenance by Users
8-2 Sending the Instrument for Repair
8-3 Elimination of Operation and Use Problems
Chapter Five: Use of PC-LINK..........................38
Chapter Six: Application Example.....................48
Chapter Seven: Instrument calibration...............55
Chapter Eight: Repair & Maintenance...............56

LA-100P User’s Manul
Instructions on Warranty of Logic Analyzer
Leaptronix provides its manufactured and sold products with a
one-year warranty on the parts and assembly dating from the delivery
date. In event of a defect merging during the warranty period,
Leaptronix will provide data for free and repair the products suffering
from a defect; however, disposable data are beyond the warranty
scope.
To share the service provided by this warranty, customers should, in
the beginning of the warranty period, make Leaptronix it known to
Leaptronix through following manners and conduct proper
arrangement for the smooth realization of services:
(1) To fill in the product warranty with complete content and deliver it
to Leaptronix through fax.
(2) To inform personnel in Leaptronix's service center of the complete
contents of various items in the product warranty through a
telephone call.
In case of a occurrence of warranty event, a customer should be liable
to pack the product suffering from a defect properly and to deliver it
to a agent or distributor service center designated by Leaptronix, with
freight born on him or herself. In case that the customer is in a
country the same as the service center of Leaptronix, Leaptronix will
be liable to pay the back freight of product. Otherwise, the customer
needs to pay all freight, duty, tax and any other expense.
This warranty is not applied to defects, invalidation or damage caused
by any improper use, and improper or insufficient maintenance and
attention. During the warranty period, Leaptronix shall not provide
services to customers under following circumstances:
(1) Damages caused by personnel on behalf of Leaptronix during
installation, repair or services
(2) Damages caused by improper use or connection with incompatible
equipment
(3) Any damage or functional abnormality caused by a use of
disposable data not provided by Leaptronix
(4) Any amendment or combination with other products which results
in the fact that difficulty or time of service-providing thereby rises
This warranty is provided by Leaptronix. Leaptronix shall bear any
responsibility for any sale or resale bearing a specific purpose.
Repairing or replacing products suffering from defects is a
supplementary measure of Leaptronix to protect the rights and
interests of customers during the warranty period. Leaptronix shall
bear no any responsibility for any indirect, particular, accidental or
consequential damage, no matter whether a pre-reminder is available
or not.

LA-100P User’s Manul
Instructions on Warranty on Consumptive
Accessories of Logic Analyzer
Parts or subassemblies beyond the main machine itself and external
box are all consumptive accessories and therefore are not in the
warranty scope. It is necessary for a customer to check whether there
is any defect of parts and subassemblies within 30 days dating from
the purchase date and, if any abnormality, to deliver the product to an
agent designated for marketing with the part or subassembly attached
so as to replace it with a new one.
List of Consumptive Parts or Subassemblies
● 8CH Data Pod
(Including rainbow strand group)
● 8CH Lead Set
● Test Probe ● USB A to B Cable

LA-100P User’s Manul
Chapter One: Product Instructions
-1-
1-1 Product Overview
Since its establishment in 1980, Leaptronix has been devoting itself
to the record and measurement of IC, with the goal to provide
manufactures with a perfect R & D environment and superior
measuring instruments. Considering the measuring need of various
products in digital era, our company has intensified the combination
with various industries and established a measuring instrument
business group (Leaptronix), providing digital system with the most
important and basic instruments, i.e. the series products of logic
analyzer. The LA-100P is one of the representative of products of
the Test & Measurement.
The LA-100P is 32 channels, 250MHz timing, 100 state Logic
Analyzer. It help minimize the risk by providing the most reliable,
accurtate data captre and the most complete view of system
behavior, These products are ideally suited for you on hardwae &
software debug, parametric and mixed signal testing and complex
debugging. Moreover, their compact size and ability to connect to a
PC make it an ideal solution for use at remote sites.

LA-100P User’s Manul
Chapter One: Product Instructions
-2-
1-2 Safety and Precautions
All operations, maintenance and repair services should be subject to
following safety precautions; our company shall bear no
responsibility to any unpredictable phenomenon resulting from an
improper use of this instrument while failing to follow the
precautions presented in this manual.
1. Please confirm advance to the use of power supply that a correct
input AC voltage has been adopted and that a correct fuse has
been installed. Specific standards and specifications are shown in
the instructions of the product.
2. Before turning on the instrument, you must connect the
protective earth terminal of the instrument to the protective
conductor of the mains power cord. You must not negate to
protective action by using an extension card (power cable)
without a protective conductor (grounding). Grounding one
conductor of a two-conductor outlet is not suffieient protection.
3. Only fuses with the required rated current, voltage, and specified
type should be used.
4. Do not operate or use this product beside any flammable gas or
fumes.
5. It is prohibited to use this product with its shell dismantled, or to
adjust or replace internal parts so as to avoid improper motions
of instrument and unnecessary dangers.
WARNING!
This sign means that attention should be paid to
dangers may happen and that personal injuries will
possibly happen in case that the operator fails to operate correctly
or to follow the procedure. Under his circumstance, the operator
should not continue with the operation with a exception that he or
she indeed knows the operation procedure.
CAUTION!
The Caution sign demotes a hazard. It calls attention
to an operating procedure, practice, or the like, which,
if not corretly performed or adhered to, could result in damage to or
destruction of part of the product. Do not proceed beyond a
Caution symbol until the indicated conditions are fully understood
or met.

LA-100P User’s Manul
Chapter One: Product Instructions
-3-
1-3 Specifications and Characteristics of Product
Items Specifications
Time sequence analysis (frequency capture)
State analysis (external clock)
Bandwidth
Channel
MEMORY
TRIGGER
Threshold Range
Maximum Input Voltage
Impedance
Temperature
Data Skew(Channel to Channel)
Interface
Power
Dimension
RAM Size
Storage Depth per Channel
Condition
Channels
Pre/Post Trigger
Trigger Levels
Continue Trigger
Range
Acuracy
Operating
Storage
Power Source
Normal consumed power
Max Power Dissipation
(Length x Width x Height)
250MHz~25Hz(4ns~40ms)
100MHz~1Hz(10ns~1sec)
100MHz
8CH x 4(0~31)
2M Bytes
512kbits x 32CH
Pattern / Edge / AND / OR
Trigger Counter 1~255
32CH
YES
YES
Trigger out YES(TTL Level)
Pulse Width Trigger YES
Bus Analysis YES
Glitch Capture YES
3 (Edge or Pattern)
-4V~+4V
±50mV
±30V
100KΩshunted by 10pF
0℃~45℃(32℉~113℉)
-40℃~75℃(-56℉~167℉)
2ns typical, ±4ns MAX
AC:90~240V,50~60Hz
AC 250V/2.0A
18.0W
20.0W
USB 2.0
31cm x 9cm x 15cm
Weight 3.8kg
Power Dissipation
Fuse

LA-100P User’s Manul
Chapter One: Product Instructions
-4-
1-4 Standard Accessories of LA Series Products
NO
01
02
03
04
06
07
08
09
Title of Accessories
CD
Warranty Card
USB 2.0 Cable
Lead Set
Qty
1
1
Main Unit 1
Test Probe
10
Packaging Confirmation
Form
11
05
User's manual
4sets
(32CH)
4sets
(32CH)
1
1
1
AC power cord 1
1
Data Pod
Chinese Operation Edition
Remark
Including,line,
connecting software,
drive program, manual
Three-wire type
List out the packing
subassemblies of product
1
package 36 pieces
Including rainbow
strand group

LA-100P User’s Manul
Chapter One: Product Instructions
-5-
1-5 Selection of Accessories
● 8CH Data Pod
(Including rainbow strand group)
● 8CH Lead Set
● Test Probe ● USB A to B Cable
Table des matières
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur