Launch X-431 GDS Manuel utilisateur

V1.00.000
2011-08-06

LAUNCH X431 GDS Sensorbox Manual
ii
All rights reserved! No part of this publication may be reproduced, stored in
a retrieval system or transmitted, in any form or by any means of electronic,
mechanical, photocopying and recording or otherwise, without the prior
written permission of LAUNCH.
This manual is designed only for the use of this unit. LAUNCH is not
responsible for any use of this manual on the other units.
he manual and all the samples herein can be changed without prior notice.
Neither LAUNCH nor its affiliates shall be liable to the purchaser of this unit
or third parties for damages, losses, costs or expenses incurred by
purchaser or third parties as a result of: accident, misuse, or abuse of this
unit, or unauthorized modifications, repairs, or alterations to this unit, or
failure to strictly comply with LAUNCH operating and maintenance
instructions.
LAUNCH shall not be liable for any damages or problems arising from the
use of any options or any consumable products other than those designated
as Original LAUNCH Products or LAUNCH Approved Products by LAUNCH.
Notice: other product names used herein are for identification purposes only
and may be trademarks of their respective owners. LAUNCH disclaims any
and all rights in those marks.
This device is only for professional technicians and maintenance personnel.

LAUNCH X431 GDS Sensorbox Manual
iii
Registered Trademark
LAUNCH is a registered trademark of LAUNCH TECH. CO., LTD.
(LAUNCH) in China and other countries. In other countries where any of the
LAUNCH trademarks, service marks, domain names, logos and company
names is not registered, LAUNCH claims other rights associated with
unregistered trademarks, service marks, domain names, logos and company
names. Other products or company names referred to in this manual may be
trademarks of their respective owners. You may not use any trademarks,
service marks, domain names, logos or company name of LAUNCH or any
third party without permission from the owner of the applicable trademarks,
service marks, domain names, logos or company name. You may visit
LAUNCH at http://www.cnlaunch.com for the information of Launch's and the
other specialized diagnostic tools, or contact Launch by visiting
http://www.X431.com or writing to Customer Center, LAUNCH TECH. CO.,
LTD., Launch Industrial Park, North of Wuhe Avenue, Banxuegang, Bantian,
Longgang, Shenzhen, Guangdong. P.R. China, to request written permission
to use materials on this manual for purposes or for all other questions
relating to this manual.

LAUNCH X431 GDS Sensorbox Manual
iv
Precaution on Operation
zThe appliance is a sophisticated electronic device, never have it
clashed when in use.
zMain unit screen may flash at the moment of engine ignition, which is
normal.
zYou may unplug the main unit if the program can not be actuated or
confused screen occurs. Plug again to continue the operation.
zMake sure the appliance is properly connected to the DLC to avoid
communication interruptions.
zDuring operation, keep the screen upward and leveled.
zBe careful when plugging and unplugging the main cable and
diagnostic connector. Tighten the screw before operation to avoid
unexpected disconnecting and/or damage to the port.
zHandle with care. Avoid collision. Unplug the power after operation.
zDo not insert or pull the GDS card when the main unit is powered on.
zAfter the operation, the stylus shall be inserted into the hole on the
back of the main unit, and put away the cable and connector, etc
accessories to the box to avoid the lost.
zUnplug the power cable by holding the connector, not the cable itself

LAUNCH X431 GDS Sensorbox Manual
1
Contents
1 Foreword ................................................................................................2
1.1 Product summary..............................................................................2
1.2 Product features................................................................................2
1.3 Product function...............................................................................3
1.4 Technical parameters........................................................................3
2 Structure and Accessories .....................................................................4
2.1 Sensorbox structure .......................................................................... 4
2.2 Sensorbox accessories ......................................................................5
3 Sensor Simulation..................................................................................7
3.1 Connection........................................................................................7
3.2 Start simulation test..........................................................................7
3.2.1 DC voltage simulation...............................................................8
3.2.2 Constant frequency simulation................................................10
3.2.3 Predefinition waveform simulation ......................................... 11
3.2.4 Hand-drawn waveform............................................................14
3.2.5 Precautions on checking vehicle sensor ..................................16
4Auto Multimeter...................................................................................18
4.1 Main interface.................................................................................18
4.2 Test sample.....................................................................................20

LAUNCH X431 GDS Sensorbox Manual
2
1 Foreword
1.1 Product summary
X-431 GDS is a new generation of sophisticated and integrated Automotive
diagnose product with colorful screen and powerful functions developed by
LAUNCH, it provide a optional function of Automotive sensor simulation .test
“Sensor simulation test” function is specially developed to diagnose and
simulate vehicle sensor faults, including "DC voltage simulation", "Fixed
frequency simulation", "Predefined waveform simulation", and
"Hand-drawing waveform simulation", which can help customer to diagnose
and simulate the vehicle sensors quickly and conveniently.
Vehicle sensors are the signal input devices for electrical control systems,
which can transform all kinds of running parameters, such as vehicle speed,
coolant temperature, engine RPM, air flow, throttle opening, etc., into the
electronic signal for the vehicle computer who can optimize the engine
running status per the above-mentioned parameters to keep the engine
working in a prime status.
Mean while, it has integrated the functions of Auto Multimeter Users can
perform voltage, resistance, frequency test by just clicking the voltage test,
resistance test, or frequency test. (The function uses the same hardware
device with the sensor module)
1.2 Product features
zDC voltage simulation
zConstant frequency simulation

LAUNCH X431 GDS Sensorbox Manual
3
zPre-defined waveform simulation
zHand-drawn waveform simulation
1.3 Product function
Provide Automotive sensor simulation test function and Automotive
multimeter test function
1.4 Technical parameters
Sensorbox
Parameters Scope
Precision ±5%
Voltage range -12V~+12V
Max output current 70mA
Predefined frequency range 0~150Hz
Square-wave signal pulse
frequency 0~15KHz
Square-wave signal duty ratio 10%~90%
Multimeter
Parameters Scope
Precision ±5%
Testing range DC-400V~+400V
Voltage test
Input impedance 10Mohm
Resistance
test
Testing range 0~40Mohm
Frequency Testing range 0~25KHz

LAUNCH X431 GDS Sensorbox Manual
4
Input impedance 1000Gohm
test
Input voltage 1~12V
2 Structure and Accessories
2.1 Sensorbox structure
Fig. 2-1 Structural diagram of Sensorbox
Table 2-1 shows the ports and indicators for X-431 GDS sensorbox
No Name Description
1 VΩHz Measuring terminal of multimeter
2 COM Common terminal of multimeter
3 Power interface Connect DC 12V power via the power adapter.
4 B-shaped USB
interface
Connect main set via USB connect wire as a
separately USB device

LAUNCH X431 GDS Sensorbox Manual
5
5 Power indicator Sensor power indicator, which will be steady
red after the sensor module is powered up.
6 Indicator for
sending data to
main unit
Indicator (Green) for sending data to main
unit.
7 indicator for
receiving data from
main unit
Indicator (Green) for receiving data from main
unit.
2.2 Sensorbox accessories
X-431 GDS sensorbox accessories include sensor test cable, probe etc. As
the product configuration can be different, the accessories included with the
product may differ from the accessories listed on this manual. Please see the
packing list attached to the product for the detailed accessories.
Following are the figures for various test cable and related accessories:
Fig.2-2 sensor test cable
Fig. 2-3 Sensor probe

LAUNCH X431 GDS Sensorbox Manual
6
Fig.2-4 Multimeter probe
Fig. 2-5 Electric control convertor cable1
Fig. 2-6 Electric control convertor cable 2
Fig. 2-7 Electric control convertor cable 3
Fig. 2-7 Electric control convertor cable 4
Autres manuels pour X-431 GDS
2
Table des matières
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur











