Water Draining System – CWDS-01 -
- 7 -
6. Installation
1. Install the base of the water draining system perpendicular to the floor and the pipe
connection supine.
2. Secure it with 4-M8 screws.
3. Secure it firmly so that the water draining system will not be unbalanced.
4. When installing, ensure that the "Robot water outlet" is 200 mm lower than the
"Cap tip removal check" limit switch on a tip changer.
5. When installing, the connection piping between the water of the robot base and the
water draining system must be within 1500 mm.
6. Since some air will flow into the cooling conduit during the first installation,
remove the air before using the water draining system.
7. Since the water draining system is activated by energization to the solenoid valve,
keep the solenoid valve energized during tip replacement and switch off the solenoid
valve after the replacement is complete.
8. Conduit connection conditions:
8-1. The solenoid valve is required to control the water being conveyed to the robotic
gun and the water flow in and out of the air unit. It is therefore necessary to make sure
that successful control of shutoff / connection of the conduit is ensured.
8-2. When using such residual water, connect the pipes appropriately according to the
water inflow and outflow method. For more details, refer to the piping connection
diagram.
7. Piping connection
Note: When using the water draining system, note that the welding gun has a separate cooling conduit,
as shown below, which must be controlled by the separate valve.
system
incoming
water
Drainage of residual water