KOHTECT qb701 Manuel utilisateur

2017
KOHTECT qb701
LASER SHAFT ALIGNMENT SYSTEM
USER’S MANUAL

qb701 User’s Manual
2
CONTENT
General .................................................................................................................. 4
Safety Precautions ................................................................................................ 4
Laser Safety Precautions ........................................................................................ 4
EC Declaration of conformity .................................................................................. 5
Technical Description................................................................................................ 6
Designation .......................................................................................................... 6
Misalignment Parameters ....................................................................................... 7
Specification and Features...................................................................................... 8
System Package.................................................................................................... 9
System overview................................................................................................... 9
Mounting Transducers.......................................................................................... 10
Laser Beam Adjustment ....................................................................................... 11
Getting Started...................................................................................................... 12
Common control keys consideration ...................................................................... 12
Auto save........................................................................................................... 12
Device setup....................................................................................................... 12
setup Menu Items ............................................................................................... 13
Horizontal Machine Alignment.................................................................................. 15
Short Explanation................................................................................................ 15
Transducer’s Positions Conventions ....................................................................... 15
Parameters......................................................................................................... 16
Tolerance Setup .................................................................................................. 17
Taking Measurements. Clock Mode ........................................................................ 18
Taking Measurements. Multipoint Mode.................................................................. 20

qb701 User’s Manual
3
Taking Readings. Auto Shooting mode ................................................................... 20
Readings quality assessment ................................................................................ 21
Editing of measurement points.............................................................................. 21
Result Screen ..................................................................................................... 22
Movable machine Adjustment ............................................................................... 23
Machines with Spacer Shaft .................................................................................. 24
Lock Feet Pair ..................................................................................................... 25
Report file saving ................................................................................................ 26
Soft Foot............................................................................................................... 27
Vertical Machine Alignment ..................................................................................... 29
Short Explanation................................................................................................ 29
Transducer’s Positions Conventions ....................................................................... 29
Parameters......................................................................................................... 30
Taking Measurements. Clock Mode ........................................................................ 31
Result Screen ..................................................................................................... 32
Machine Correction @45 ...................................................................................... 34
Charging batteries............................................................................................... 35
Firmware Upgrade............................................................................................... 36
Firmware Upgrade Using Windows Mobile Device Center .......................................... 38
Standard Tolerances of Shaft Misalignment ............................................................... 40
Delivery Set .......................................................................................................... 41

qb701 User’s Manual
4
GENERAL
SAFETY PRECAUTIONS
Be sure the machines to be measured, cannot be started unintentionally as this can cause
injuries. For this purpose, before the mounting of equipment, either block the power switch
in the “Off” position or remove the safety fuses. These precautionary rules must be
followed until the measuring system is dismantled from the measured machine.
LASER SAFETY PRECAUTIONS
The KOHTECT qb701 alignment system is the class II laser device at typical wavelength of
650nm, delivered output power of less than 1 mW and maximum radiant energy per pulse
of 0.1 mJ. The Class II laser comply with requirement outlined by USA’s FDA as well as
international ANSI, BS 4803 and IEC 825 standard. Be sure to follow the following safety
precautions to avoid personal injuries and damage to the system
Do not look directly into the laser beam at any time!
Do not direct laser beam on to the people’s eyes!
ATTENTION!
Do not expose qb701 parts to heavy impacts, high humidity and extreme temperature.
Do not try open / dismantle measuring units and the display unit –this can damage the
system, and your after-sales service warranty will come void.
INJURY RESPONSIBILITY DISCLAIMER
Neither the NPP KOHTECT enterprise nor our authorized dealers are liable for the damages
caused to machinery or equipment by use of the qb701 system. We carefully check text of
this manual to eliminate errors, nonetheless there may be mistakes or inaccuracy involved.
We will be grateful for your reporting to us about any error, and we will be able to correct
them in the subsequent editions of the manual.

qb701 User’s Manual
5
EC DECLARATION OF CONFORMITY
We, NPP KOHTECT, 167, Pogranichnaya str., 201, Nikolaev, Ukraine herewith
declare that the following product:
Shaft Alignment Tool qb701
has been designed and manufactured in accordance with: EMC DIRECTIVE
2004/108/EC as outlined in the harmonized norm for EN 61326-1:2013 Electrical
equipment for measurement, control and laboratory use –
Part 1: General Requirements,
EN 55011: 2009 +A1:2010, EN 61000-4-2: 2009, EN 61000-4-3: 2006 +A1:2008
+A2:2010, EN 61000-4-4: 2004 +A1:2010, EN 61000-4-5: 2006, EN 61000-4-6:
2009, EN 61000-4-11: 2004
EUROPEAN ROHS DIRECTIVE 2011/65/EU
The laser is classified in accordance with the EN 60825-1:2007. The laser complies
with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice
No. 50, dated June 24, 2007.
Kiev, Ukraine, Dec 17, 2015
Oleg Ivanov, Head of Product Development

qb701 User’s Manual
6
TECHNICAL DESCRIPTION
DESIGNATION
qb701 alignment system (further as System) is designed for measurement of shaft axis
misalignment of coupled machines, and calculation of movable machine adjustment
required to eliminate misalignment that exceeds permissible tolerances;
The machine alignment means adjustment of the relative position of two coupled machines
(e.g. motor and pump) so that the center line of the axis will be concentric when the
machines are running under normal working conditions.
S transducer
installed on the
shaft of Stationary
machine
M transducer
installed on the
shaft of the
machine to be
moved

qb701 User’s Manual
7
S–stationary machine
M–moveable machine
Shaft Angular (Gap)
value
Shaft Parallel (Offset)
value
Vertical adjustment values
S
M
MISALIGNMENT PARAMETERS
Misalignment of any rotating machine is expressed in parallel (Offset) and angular (Gap) of
the shafts. Most frequently in practice, both of them are present simultaneously. Different
kinds of misalignment of axes are shown in Fig. 2.
The parallel (Offset) and angular (Gap) misalignment of axes is determined in two
mutually perpendicular planes. For the purpose of elimination of the parallel and angular
misalignment of axes, in each of the planes a correction of position of the movable
machine (M) will be done.
For the horizontal mounted machine –the movable machine (M) position is adjusted in the
horizontal and vertical planes.
For the vertical mounted machine, operator determines arrangement of the correction
planes, basing on considerations of the convenience and technological effectiveness of
moving of the movable (M) machine.
Stationary machine (S) - in the process of eliminating of the axes misalignment the
position of this machine stay static, i.e. it does not move.
Movable machine (M) –the machine, which position is adjusted for eliminating of the
parallel and angular misalignment of axes.
The measurement system calculates the values of the angular and parallel misalignment of
axes in the plane of the coupling (in two mutually perpendicular planes), and the
adjustment values for the machine feet on the movable (M) machine, that is necessary for
elimination of this misalignment of axes. Fig. 3 shows misalignment of axes and the values
for its correction just for vertical plane.
Parallel misalignment of axes –Offset (displacement)
Angular misalignment of axes –Gap
Parallel and angular misalignment of axes –(Offset + Gap)
Fig 2

qb701 User’s Manual
8
SPECIFICATION AND FEATURES
-Separation distance between measuring transducer units, up to 10 m
-Display control operating temperature range, -10..+55 degree C
-Measurement accuracy, 1%+0.01
-Laser type: Visible red 635-670 nm, <1 mW
-Detector type: CCD, length 30 mm
-Display resolution, 0.01 or 0.001 mm, (1 or 0.1 mil )
-Measuring resolution, 0.001mm
-Electronic inclinometer resolution, 0.1 degree
-Power supply: Rechargeable Li-Ion battery
-Gross weight, incl. carry case, 3.9 kg
-Built-in application programs and options:
ohorizontal shaft alignment at any shaft position, from 60°, up to 360º, up to 36
readings can be measured; auto sweep mode can be used;
overtical (flange machine) shaft alignment;
oeditable misalignment tolerances;
osetup options;
osoft foot;
othermal growth;
oshimming simulator to calculate for expected residual misalignment;

qb701 User’s Manual
9
3
1
4
2
5
8
SYSTEM PACKAGE
The System includes (Fig. 1):
1- AVV-711 display unit
2- two measuring transducer units –S, M
3- universal chain brackets for mounting of
measuring units S, M
4- measuring tape
5- 120…240 Volts AC charger
6- USB PC communication cable
7- Operating instructions manual and ConSpect
freeware on the internal drive of display unit
8- Carrying case with form-inserted
SYSTEM OVERVIEW
Locking
thumb nut
Mini USB
charger
connector
Detector
window
Laser
aperture
Power
button

qb701 User’s Manual
10
4
1
3
2
5
1
MOUNTING TRANSDUCERS
•Firmly tighten rods 1 into the shaft brackets 2.
•Put thumb nut 3 into the bracket 2, then hook the chain 5 on the stud 4.
•Firmly tighten the thumb nut 3. Shaft brackets with rods must be mounted at the
same angular position.
•Mount transducers on the rods. Always try to mount transducers at minimal
possible radial height. Make sure that transducers are not touching brackets or
machine parts.
S, M transducers to be
installed at the same
height with labels faced up
Datum lines for measuring
of dimension input
Locking
thumb nut
M transducer
installed on
the machine
to be moved
S transducer
installed on
the stationary
machine
Table des matières
Autres manuels KOHTECT Instrument de mesure
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur