Keysight Technologies 81160A Manuel utilisateur

Keysight 81150A and 81160A
Pulse Function Arbitrary
Noise Generators
Demo Guide, Version 1.0

High precision pulse generators enhanced with versatile
signal generation, modulation and distortion capabilities for:
– Accurate signals to test your device and not your signal source
– Versatile waveform and noise generation to be ready for today‘s and tomor-
row‘s stress test challenges
– Optional pattern generator to test in addition to analog, digital and mixed
signal devices
– Integrated into one instrument to minimize cabling, space and test time

– 1 µHz – 120 MHz pulse generation with variable rise/fall time
– 1 µHz – 240 MHz sine waveform output
– 14-bit, 2 GSa/s arbitrary waveforms
– 512k samples deep arbitrary waveform memory per channel
– Pulse, sine, square, ramp, noise and arbitrary waveforms
– Noise, with selectable crest factor, and signal repetition time of 26 days
– FM, AM, PM, PWM, FSK modulation capabilities
– 1 or 2 channel, coupled and uncoupled
– Differential outputs
– Two selectable output ampliers:
– High bandwidth amplier
Amplitude: 50 mVPP to 5 VPP; 50 Ω into 50 Ω
100 mVPP to 10 VPP; 50 Ω into open
Voltage window: ± 5 V; 50 Ω into 50 Ω
± 10 V; 50 Ω into open
± 9 V; 5 Ω into 50 Ω
– High voltage amplier
Amplitude: 100 mV
PP
to 10 V
PP
; 50 Ω into 50 Ω, 200 mV
PP
to 20 V
PP
;
5 Ω into 50 Ω, or 50 Ω into open
Voltage window: ± 10 V; 50 Ω into 50 Ω
± 20 V; 5 Ω into 50 Ω or 50 Ω into open
– Glitch free change of timing parameters
(delay, frequency, transition time, width, duty cycle)
– Programming language compatible with Keysight 81101A, 81104A, 81105A,
81110A, 81130A and 81160A
– ISO 17025 and Z540.3 calibration
– LXI class C (rev. 1.1) compliant
– Optional pattern generator:
– Ideal and arbitrary bit shaped pattern up to 120 Mbit/s
– Two, three or four level signals
– PRBS up to 231
– 16 Mbit pattern memory
– Pass through pattern for combined and physical and protocol test
up to 10 Mbit/s
The 81150A Pulse
Function Arbitrary
Noise Generator at
a glance
811 A
50
03 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide

– 1 µHz – 330 MHz pulse generation with variable rise/fall time
– 1 µHz – 500 MHz sine waveform output
– 14-bit, 2.5 GSa/s arbitrary waveforms
– Up to 256k samples deep arbitrary waveform memory per channel
– Pulse, sine, square, ramp, noise and arbitrary waveforms
– Noise, with selectable crest factor, and signal repetition time of 20 days
– FM, AM, PM, PWM, FSK modulation capabilities
– 1 or 2 channel, coupled and uncoupled
– Differential outputs
– Amplitude:
50 Ω into 50 Ω 50 mVPP to 5 VPP
50 Ω into open 100 mVPP to 10 VPP
– Voltage window:
50 Ω into 50 Ω ± 5 V
50 Ω into open ± 10 V
– Glitch free change of timing parameters
(delay, frequency, transition time, width, duty cycle)
– Programming language compatible with Keysight 81101A, 81104A, 81105A ,
81110A, 81130A and 81150A
– ISO 17025 and Z540.3 calibration
– LXI class C (rev. 1.1) compliant
– Optional pattern generator:
– Ideal and arbitrary bit shaped pattern up to 330 Mbit/s (Option 330) or
660 Mbit/s (Option 660)
– Two, three or four level signals
– PRBS up to 231
– 4 Mbit pattern memory for the 1-channel instrument and 2 Mbit per
channel for the 2-channel instrument
– Pass through pattern for combined and physical and protocol test
up to 10 Mbit/s
The 81160A Pulse
Function Arbitrary
Noise Generator at
a glance
811 A
60
04 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide

Couple/uncouple channels
External In
Trigger mode
Waveform type
Advanced mode
Channel 2:
Trigger out
Strobe out
Differential output
Channel 1:
Trigger out
Strobe out
Differential output
USB 2.0A
USB 2.0 A
USB 2.0 B
LAN GPIB
10 MHz Ref in
10 MHz Ref out
Modulation in 1, 2
811 A
50
05 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide

Couple/uncouple channels
External in
Trigger mode
Waveform type
Advanced mode
Channel 2:
Differential
output
Channel 1:
Differential
output
Sync out A and B:
The logical trigger signal 1
or logical trigger signal 2
or logical strobe signal 1
or logical strobe signal 2
can be routed by a fully
flexible internal switch
matrix to Sync Out A or
Sync Out B.
USB 2.0A
USB
2.0A
USB
2.0B
LAN
GPIB
Modulation in 1, 2
10 MHz
Ref out
10 MHz
Ref in
811 A
60
06 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide

Introduction Keysight Technologies, Inc. pulse generators are focused on high signal integrity
to provide clear, stable and repetitive signals. This is required for all kinds of
DUT development in R&D, followed by dedicated stress test with distorted and
real world signals. A key and unique feature of the Keysight 81150A and 81160A
Pulse Function Arbitrary Noise Generators is to combine two independent output
channels. There are two ways of doing this. Either couple the channels or add
the channels together.
Required Equipment for this Lab:
1. 1x Keysight Pulse Function Arbitrary Noise Generator with two output
channels (81150A/81160A incl. option 002)
2. 1x Keysight Oscilloscope DSO or MSO6104A incl. 4x BNC cables
How to hook up the instruments:
1. Connect ‘OUTPUT 1’ (81150A and 81160A) to channel 1 (scope)
2. Connect ‘OUTPUT 2’ (81150A and 81160A) to channel 2 (scope)
3. Connect ‘STROBE OUT 2’ (81150A), ‘Sync Out B’ (81160A) to channel 3 (scope)
4. Connect ‘TRIGGER OUT 2’ (81150A), ‘Sync Out A’ (81160A) to channel 4 (scope)
5. 81160A only: select ‘Ch 2’, select ‘Trig’, go to ‘Trigger Out’ and set it to ‘Sync A’
6. 81160A only: set ‘Strobe Out’ to ‘Sync B’
07 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide

1. Select ‘CHANNEL 1’ (button ‘CH 1’)
2. Enable ‘CONTINUOUS TRIGGER MODE‘ (button ‘Cont’)
3. Select ‘PULSE WAVEFORM’ (button ‘Pulse’)
4. Enter the pulse shape parameters:
Frequency: 1 MHz
Delay: 0 ns
Amplitude: 2.000 VPP
Offset: 1 VDC
1) Set up the first channel
2) Set up the second channel
1. Select ‘CHANNEL 2’ (button ‘CH 2’)
2. Select ‘SINE WAVEFORM’ (button ‘Sine’)
3. Enter the sine wave parameters:
Frequency: 2 MHz
Delay: 10 ns
Amplitude: 3.000 VPP
Offset: 0 VDC
Coupling between
channels
In this lab it is shown how two channels can be coupled, so that the instrument
behaves like a two-channel instrument with only one timebase. As a result of
coupling, the output function and all other parameters like burst, sweep and
modulation are also kept identical.
The very first task you should always perform, is to reset the instrument to
default settings (‘STORE/RECALL’ and ‘SET TO DEFAULTS’).
08 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide

4) Set up the burst length
1. Set the burst length for channel 2. (button ‘Burst’)
This enables coupling of both channels. Since channel 1 is currently selected,
the settings of channel 2 will be adjusted to match the settings of channel 1. As
a result the following parameters of channel 1 are copied to channel 2:
Waveform: pulse wave is applied to Channel 2
(incl. all parameters without delay)
Trigger mode: changed from ‘TRIGGERED’ to ‘CONTINUOUS’.
Burst: set to ‘OFF’.
5) Switch back to channel 1
and enable coupling
(button ‘Coupling’)
3) Enable the trigger mode
1. Select ‘TRIGGER MODE’for Ch2 (button ‘Trig’)
2. Select ‘SINEWAVE’ as trigger signal
3. Enter trigger source (e.g. External In)
4. Triggered by rising edge
5. Set ‘TRIGGER OUT’and ‘STROBE OUT’ to TTL or ECL
09 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide

Channel adding
(this requires a two
channel instrument)
In this exercise we add the output signals of the two independent output chan-
nels together. This is the only way to generate distorted signals out of standard
waveforms. Even more flexibility is provided when using Arb based signals on
one channel.
Please reset the instrument to default settings
(‘STORE/RECALL’ and ‘SET TO DEFAULTS’).
1) Set up the first channel
1. Select ‘CHANNEL 1’
2. Enable ‘CONTINUOUS TRIGGER MODE’
3. Select ‘PULSE WAVEFORM’
4. Enter the pulse shape parameters:
Frequency: 1 MHz
Width: 500 ns
Delay: 0 ns
Amplitude: 3.000 VPP
Offset: 0 VDC
Lead Edge: 75 %
Trail Edge: 50 %
Note: Make sure that the channels are not coupled
(Coupling key is not highlighted).
2) Set up the second channel
Enter the pulse shape parameters:
Frequency: 1 MHz
Width: 10 ns
Delay: 200 ns
Amplitude: 2.000 VPP
Offset: 0 VDC
Lead Edge: 2.5 ns
Trail Edge: 2.5 ns
10 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Keysight Technologies Onduleur

Keysight Technologies
Keysight Technologies P9336A Guide de l'utilisateur

Keysight Technologies
Keysight Technologies E8257D Manuel utilisateur

Keysight Technologies
Keysight Technologies E4360A Manuel utilisateur

Keysight Technologies
Keysight Technologies Y1165A Manuel utilisateur

Keysight Technologies
Keysight Technologies 81133A Manuel utilisateur

Keysight Technologies
Keysight Technologies N5991 Manuel utilisateur

















