JensPrima innoCon 6501P Manuel utilisateur

WALL MOUNTING
innoCon 6501
CAL


innoCon 6501 Monitor Manual
www.jensprima.com
Contents
Safety 2
3
5
5
6
7
8
9
10
11
12
13
17
............................................................
Product Introduction....................................................
Installation
.................................................................
...................................................
Display
Electrical Connection
...................................................................
Configuration Mode...................................................
Calibration Mode .......................................................
Maintenance
.........................................................
P010 Temperature parameter setting
.................................
Controller Installation.................................................
Sensor Installation
....................................................
P020 Relay 1 parameter setting
.......................................
15
15
16
pH Calibration
.......................................................
ORP Calibration
.....................................................
P030 Relay 1 parameter setting
......................................
P040 Current output parameter setting
P050 Offset parameter setting
P060 Measurement parameter selection
P070 Factory Reset
.......................................
13
14
14
..............................
..............................
...................................................
Page 1

innoCon 6501 Monitor Manual
Page 2www.jensprima.com
Safety
Legal requirements
Sensor
Signs
√ This manual introduces all the risks that may arise during the use of this equipment,
√ Please make sure this manual is delivered to the third party along with innoCon 6501.
.
Please use sensors manufactured by JENSPRIMA; Damages to the instruments caused
by the use of sensors not manufactured by JENSPRIMA within the warranty period will
not be covered by the warranty.
Only technicians authorized by jensprima can modify and update the instrument.
of corresponding regions and countries.
This sign is used to instruct the operator.
!

innoCon 6501
CAL
innoCon 6501 Monitor Manual
Product Introduction
General Information
The innoCon 6501P economical controller is designed for online monitoring of water
treatment and industrial process, matching with innoSens pH / ORP electrodes for
measuring pH / redox potential and temperature in water. Pt 1000 automatic
temperature compensation, installation methods of panel/pipe way, standard with
one line of 4-20mA output and two lines of relay output.
Applicaitons
Sewage / wastewater treatment, environmental monitoring, industrial processes,
swimming pools etc.
Supply
1. innoCon 6501P Controller
2. Fixed bracket
3. Operation Manual
4. innoSens pH/ORP Sensor (Need to purchase separately)
Features
√The latest wide power input, economical, 4-20mA output
√Teflon terminal, super anti-interference ability
√Large-screen backlit LCD shows measured values, temperature and relay status
√Password protection, to prevent unauthorized operation
√Pt 1000 automatic temperature compensation function
√IP65 protection class, a variety of installation methods
√2 lines of High/ Low relay output
√One key to restore factory settings
www.jensprima.com Page 3

innoCon 6501 Monitor Manual
www.jensprima.com Page 4
±0.2 C
Technical Parameters
Parameters
Measurement range
Resolution
pH ORP Temperature
-10.0~120.0 C
-10.0~120.0 C
0~60.0C
-10~60.0 C
>10 Ω
12
°
°
°
°
°
-2000~2000mV-2.00~16.00pH
0.01pH
±0.01pH ±1mV
Pt 1000
1mV 0.1 C
°
Accuracy
Temp.Compensation
method
Temp.compensation
range
Ambient Temp.
Storage Temp.
Resistance input
Display
Isolated 4-20mA output, can set pH/ORP, max.500Ω
90-260VAC,50/60Hz;24VDC optional
IP65
90 x 90mm
96 x 96 x 140mm
innoSens 120 pH Sensor
Applicable to pH measuremnet of the general
water treatment and high pollution wastewater
innoSens 210 ORP Sensor
Applicable to ORP measuremnet of the general
water treatment and high pollution wastewater
innoSens 125 pH Sensor
Applicable to pH measurement of high
temperature and high pollution wastewater
such as pulp, electroplating, desulfurization
wastewater
innoSens 130 pH Sensor
Applicable to pH measurement of high temperature
sterilization, high temperature fermentation etc.
innoSens 145 pH Sensor
Applicable to pH measurement of pure water,
RO water and other low range conductivity water
innoSens 150 pH Sensor
Applicable to pH measurement of hydrofluoric acid water
0.5Kg
2 sets of ON/OFF contacts, independent setting of High
/Low alarm point, with hysteresis function; 5A/250VAC;
5A/30VDC
English/Chinese
Panel/Pipe
Backlit super large lattice LCD
Analog output
Language
Power supply
Protection class
Alarm output
Installation method
Dimension
Panel cut size
Weight
innoCon 6501P Controller Parameters:
innoSens pH/ORP Electrode:
Please refer to the
relevant technical
documents to select
the appropriate
electrode.

innoCon 6501 Monitor Manual
www.jensprima.com
Installation
The instrument can be panel mounted and pipe mounted.
Make a hole of 90 x 90mm on the instrument case, put the instrument into the case
from the front of the panel of the case, insert screws from the back cover, and then
lock the fastening block to the fastening bar from the back of the panel.
Panel Mounting
Dimension
Pipe Mounting
Page 5
Cut Size Bracket Used for Panel Mounting
Bracket
90mm
90mm
U-tube from Pipe Mounting
innoCon 6501
CAL
96mm
96mm
140mm

Installation of Sensor
JENSPRIMA has many types of industrial electrodes that have a specific connection
function. The most common installation methods are: immersion type, pipe type,
flow type, tank installation and live bolt assembly type electrode tube installation.
Note:The above-mentioned connecting parts must be tightened to prevent water from damaging the electrodes
Protection Cover Components and Installation
innoCon 6501 Monitor Manual
www.jensprima.com Page 6
innoSens 120 pH Electrode
pH 0~14, -5~70℃
Controller: innoCon 6800 & innoCon 6501
Sensor: innoSens pH/ORP Sensor
Flange type
Side wall
welding seat
Pipe type
Immersion type
Bypass type
Round junction box upper cover
innoSens 120 pH Electrode
pH 0~14, -5~70℃
El
O ring
O ring
Electrode protection tube
Protection cover
Molded shell electrode(3/4”thread)
Recommend to wrap the thread with tape
Glass electrode
Rubber seat
Fixed bracket
Water-proof cable connector
Round junction box lower ring
innoCon 6501
CAL

innoCon 6501 Monitor Manual
www.jensprima.com
Electrical Connection
Central axis connected
with cable Connect 90-260VAC
Ntework cable
conntected with cable
Relay 1
Probe connected with
temperature Relay 2
4-20mA Output
The connectors of the controller are located behind the instrument cover,
only trained personnel can open the cover for wiring power, relay and signal
outputs. Use a screwdriver to unscrew the four screws on the back cover for
electrical connection.
Terminals
Page 7
Extension of electrical wire:
When opening the wire, make sure
to remove the black conductive rubber
cover outside the central axis.
Network
Cable
Central
Axis
mA-
mA+
Pt1000
4-20mA: Isolation Max. Load 600 ohm
Relay: 5A/250VAC 5A/30VDC
pH/ORP
Ref
Relay2
Relay1
90-260VAC
50/60Hz
!
90-260VAC
50/60Hz
!Relay1
Relay2
Pt1000
pH/ORP
Ref
mA-
mA+
Danger:
Electrical connections must be
carried out by technicians who
got special trainings.
Note:
Power supply must be cut off
prior to any connection, otherwise
the instrument and the sensor are
likely to be damaged.

innoCon 6501 Monitor Manual
www.jensprima.com
Display
Front View of the Controller
Relay Indicate
Unit
Temperature
Secondary display area
Main
display
area
Calibration
ATC -- Temperature
compensation mode
ATC ( Auto)/MTC (Manual )
Button Functions:
Menu/Back
Key
Calibration
Key
Enter
Key
Arrows
Key
Under measurement interface, press and
hold this button for 3 seconds to enter the
setup menu and return to the previous menu.
Under measurement interface, press and
hold this button for 3 seconds to enter the
calibration menu
Accept input value or selected menu
Under measurement interface, press this key
Press this button to switch the display backlight
Browse menus, change settings, and input
value,under measurement interface
Press this button to switch measurement
value and current
Enter the setting mode with password 0011.
Any time press can exit the calibration mode or go back to the previous
menu. Press same key to the measuring mode.
Page 8
Current Indicate
innoCon 6501
CAL
CAL
Table des matières
Autres manuels JensPrima Instrument de mesure
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur