Ivoclar Vivadent Programat P310 Manuel

Programat®P310
Short Instructions | Kurzanleitung | Mode d’emploi : l’essentiel
Istruzioni d’uso – versione ridotta | Guía rápida | Guia Rápido


Dear Customer
Thank you for having purchased the Programat P310. In order to render the setting-up and the initial use of the furnace as easy as
possible, we have prepared these short instructions.
These short instructions replace by no means the detailed Operating Instructions. We therefore kindly ask
you to thoroughly read the Operating Instructions and follow the notes contained therein.
Enjoy working with the Programat P310.
english
Programat®P310
Short Instructions

11
2
3
12
4
5
A
C
E
B
D
F
A
B
C
D
E
F
1. Installation
Remove the furnace components from their packaging and place the
unit on a suitable table. Please observe the instructions on the outer
packaging. Make sure the voltage indicated on the rating plate com-
plies with the local power supply. If this is not the case, the furnace
must not be connected.
Mounting the cooling tray
Remove both screws for the cooling tray (1).
Place the cooling tray (2) on the frame plate (3).
Make sure that the cooling tray is correctly positioned on the
frame plate.
Secure the cooling tray with the two screws (1).
Placing the firing plate
The firing plate (4) can now be placed on the firing plate holder (5).
Mounting the furnace head
The furnace head is best mounted with the back of the furnace pointing
towards the user. Lift the furnace head with both hands as shown in the
picture and place it on the furnace head mounting.
Mount the furnace head as shown in the picture until you feel it click
into place. Make sure that neither the firing plate nor the insulation is
damaged during the mounting of the furnace head.

Establishing the connections
Connect the cables of the furnace head with the furnace base.
Proceed as follows:
- Connect vacuum hose (6).
- Insert the thermocouple plug (7). (Make sure that the polarity of
the plug is correct.)
- Insert the heater plug (8).
Insert the heater plug into the specified connector. Secure the heater plug by
rotating it by 45°.
Closing the protective cover
When all cables are correctly connected to the base, close the
cover (9) to protect the connections until you feel it click into place.
Mounting the connection cover
The connection cover (10) can now be mounted and secured with the
screws.
The furnace may only be used with the protective cover closed and
the connection cover mounted!
Establishing additional connections
Power connection
Make sure that the voltage indicated on the rating plate complies with the
local power supply. Subsequently, connect the power cord (11) with the
power socket of the Programat (12).
Connecting the vacuum pump
Connect the vacuum pump plug (13) with the vacuum pump socket (14). We
recommend using only the VP4 vacuum pump from Ivoclar Vivadent, since
this pump is especially coordinated with the furnace. If other pumps are used,
please observe and do not exceed the indicated maximum power consumption.
1
2
76
8
9
10
12
11 14
13
G
I
K
H
J
G
H
I
J
K
english

2. User interface
The Programat P310 has a wide-screen colour display. The keypad and the
touch screen allow user-friendly handling. By tapping slightly with your finger-
tips on the touch screen, the buttons are activated and the furnace performs the
requested function.
Keypad:
Home
Returning to «Home» screen (main menu)
Program key
Pressing once: The currently selected program is
displayed.
Pressing twice:
The program selection via number entry is accessed.
Power-saving key
This key activates the power-saving function.
Open furnace head Close furnace head
START (Start LED)
Starts the selected program. The green LED indicates that a pro-
gram is running. If the program is paused (1 x STOP), the Start LED
flashes until renewed pressing of START results in the program being
resumed.
STOP
A running program can be paused by pressing the
STOP key and terminated by pressing the key twice.
Movement of the furnace head can be stopped at any
time by pressing STOP. Acoustic signals can be turned
off by pressing the STOP key.

3. Operation
Turning the furnace on
Connect the power cord with the wall socket.
Switch the On/Off button to position «I».
After the self-test, the display shows the home screen. All functions of the
Programat can be selected from this screen. Click the HOME key in order
to return to the home screen.
Selecting program sections
The furnace comprises multiple program sections
a. Programs for Ivoclar Vivadent materials
b. 300 individually programmable programs
Selecting the program group
The program sections are divided into program groups.
Each program group comprises 20 programs.
Selecting the program
Select the required program.
Loading the furnace
Open the furnace head by pressing the button OPEN FURNACE HEAD and
place the object to be fired with the firing tray in the furnace.
Starting the program
Press the START key to start the program. The LED lights up green. You can see the progress in the firing curve.
At the end of the program, the furnace head opens automatically. As soon as the OSD lights up green, the furnace is available for the
next program start.
A
A
B
B
C
C
E
DD
E
english

A
A
B
B
4. Editing the firing parameters
Parameters are set or edited in two steps.
Example: Setting the holding temperature
Press the [T] button.
Enter the desired holding temperature and confirm
by pressing the green button.
The holding temperature has been changed successfully. All parameters
shown in the firing curve can be changed / edited the same way.
Changing program options
By pressing the [Options] button, the menu for additional program options
opens.
Example: Open the write-protection program
Press the [Options] button.
Edit the desired option and return to the program view
by pressing the [Close] button.
By pressing the [Arrow] buttons, you can change between the individual
option pages.
Please refer to the Operating Instructions for more
detailed information.
A B
AB

Programat®P310
Kurzanleitung
deutsch
Sehr geehrter Kunde
Es freut uns, dass Sie sich für den Kauf des Programat P310 entschieden haben. Um Ihnen die Inbetriebnahme und die erste Anwendung des Gerätes so
einfach wie möglich zu gestalten, haben wir diese Kurzanleitung verfasst.
Diese Kurzanleitung ersetzt keinesfalls die umfassende Bedienungsanleitung.
Wir bitten Sie daher, auch die Bedienungsanleitung genau durchzulesen und die Hinweise zu beachten.
Wir wünschen Ihnen viel Freude und Erfolg mit dem Gerät.

11
2
3
12
4
5
A
C
E
B
D
F
1. Installation
Gerätekomponenten aus der Verpackung nehmen und das Gerät auf einen
geeigneten Tisch stellen. Bitte beachten Sie die Anleitung auf der Aussenver-
packung. Prüfen Sie, ob die angegebene Spannung des Typenschilds mit der
vorhandenen Netzspannung übereinstimmt. Ist dies nicht der Fall, darf das
Gerät nicht angeschlossen werden!
Montage der Brenngut-Ablageplatte
Entfernen Sie die zwei Befestigungsschrauben für die
Brenngutablageplatte (1).
Legen Sie nun die Brenngut-Ablageplatte (2) auf die Rahmenplatte (3).
Achten Sie dabei, dass die Brenngut-Ablageplatte korrekt auf der
Rahmenplatte aufliegt.
Sichern Sie nun die Brenngut-Ablageplatte mit den zwei Befestigungs-
schrauben (1).
Brenntisch auflegen
Der Brenntisch (4) kann nun auf die Brenntisch-Aufnahme (5) aufgelegt
werden.
Ofenkopf montieren
Der Ofenkopf kann am einfachsten montiert werden, wenn das Ofen-Hinter-
teil zum Anwender zeigt. Heben Sie den Ofenkopf mit beiden Händen wie
auf dem Bild ersichtlich und setzen Sie ihn auf die Ofenkopfhalterung.
Die Ofenkopfhalterung wie auf dem Bild ersichtlich aufsetzen bis der
Ofenkopf spürbar einrastet. Achten Sie darauf, dass der Brenntisch
bzw. die Isolation durch die Ofenkopfmontage nicht beschädigt wird.
A
B
C
D
E
F
Autres manuels pour Programat P310
1
Table des matières
Langues :
Manuels Poêle populaires d'autres marques

Vermont Castings
Vermont Castings Intrepid 2 Manuel utilisateur

Italiana Camini
Italiana Camini CLASSICA Guide de démarrage rapide

Avalon
Avalon Vashon Avanti DVS FS Manuel utilisateur

Spartherm
Spartherm ambiente a1 Manuel utilisateur

Dimplex
Dimplex MCFSTV12AU Manuel utilisateur

Warmlite
Warmlite WL46040 Manuel utilisateur