Istore 180L Manuel utilisateur

INSTALLATION MANUAL 180L / 270L
istore.net.au
iStore - Installation Manual - June 2020

iStore - Installation Manual - June 2020
2
Important Information
• This manual includes all the necessary information regarding the Installation and
maintenance of this product. Please take the time to read it through before operating.
• When Installing the hot water cylinder, please follow the Instructions as documented in
this manual.
• Once the Installation is complete, check that all connections are secure and the unit is
full before the power is turned On.
• The installer is to explain to the end user how to operate and maintain the unit in
accordance to this Instruction manual.
• iStore will not be held responsible for any damages or injuries caused by the incorrect
Installation of this hot water system.
• It is important that the installation and operational instructions laid out in this manual
are strictly adhered to.
• A maintenance programme must be carried out as recommended in this manual.
Failure to comply with these recommendations will void the warranty.
• This manual could be subject to change without prior notice, if it is felt that product
improvements are to be carried out.

iStore - Installation Manual - June 2020
3
Content
1. Safety Precautions p4
2. Specications p7
2.1) dimensions 270L p7
2.2) dimensions 180L p8
2.3) performance parameters p9
3. Safety Features p10
4. Installation
4.1) Installation Diagram p12
4.2) Transportation p13
4.3) Installation Space p14
4.4) Multi-system conguration p16
5. Intelligent Operation Modes p17
5. Functionality p18
5.1) Function of the LED Display p18
5.2) Setting the Time p22
5.3) Setting the Timer p23
6. Maintenance and repair p29
6.1) Typical failure and solutions p29
7. Troubleshooting p31

iStore - Installation Manual - June 2020
4
Safety Precautions
To prevent personal injury and avoid causing damage to the unit, please take the time to
read the information documented in this manual.
ICON DESCRIPTION
A wrong operation may lead to serious injury or death
A wrong operation may lead to injury or loss of material
ICON DESCRIPTION
Prohibited (Next to this icon)
Compulsory - The listed action shall be followed
Please pay attention to what is indicated
The iStore must be installed by qualied persons. Improper installation
could result in electrical shock /water leakage or re
Before installation, check the unit for any damage
Please ensure that the unit and power connections have a good earth. Failure
to do this may cause an electrical shock
Do not drill any holes or screws into the outer casing. Drilling of any holes will
void the warranty
WARNING
ATTENTION
INSTALLATION WARNING

iStore - Installation Manual - June 2020
5
The unit CANNOT be installed near ammable gas.
Ensure that the position of the unit is level and in accordance with
AS/NZ 3500.4
This unit requires a circuit breaker and AC isolator. Failure to do so
could result in an electrical shock or re.
Do not put ngers or any other objects into the fans. Children
should be kept clear of this appliance.
In the event the iStore has a major malfunction, please shut the
power o and contact your iStore installer or iStore directly.
If the iStore needs to be relocated or installed again, only use an
authorised dealer or qualied persons.
It is prohibited for the end user to repair the unit themselves,
unless qualied. Failure to do so may lead to serious injury or, and
damage to the unit.
Should the iStore need to be repaired, only use an authorised
dealer or qualied persons.
Under no circumstances should water be sprayed directly into the
unit when cleaning. Only external surfaces to be cleaned with a
soft rag by non-qualied persons.
DANGER - High Temperature
INSTALLATION WARNING
RE-LOCATION OR REPAIR
CLEANING WARNING
Functionality WARNING
Safety Precautions
Unit Location
Unit Placement
Dedicated Circuit
Shut O Power
Safety Warning
Important
Important
Shut O Power
Prohibited

iStore - Installation Manual - June 2020
6
Electrical Connection:
Please check the electrical specication table. Under no circumstances shall the electrical lead be
converted to a 3 pin plug and connected to a General Power Outlet (GPO). An approved AC Isolator
shall be installed within 1m of the unit.
500kPa Pressure Reduction Valve:
Pressure Reduction Valve (PRV 500) - A pressure reduction valve of 500kPa maximum must be tted
immediately downstream of the cold water non-return isolation valve. Failure to install a pressure
reduction valve will void the warranty. Please note cold water supply line to the tempering valve must
be run after the PRV to ensure equal supply pressure to the tempering valve. This valve is not required
shall a 500kPa PRV be installed at the water main supply to the property.
Note: In SA, WA & QLD (and some other areas of other states subject to local authority regulations) it is a
requirement that an expansion control valve be tted between the non-return isolating valve and the water
heater.
How it works
1. A fan draws in air, containing heat energy, across the
evaporator
2. The evaporator turns the liquid refrigerant into a gas
3. The compressor pressurises the refrigerant into a hot gas
4. The hot gas inside the condenser coil heats the water
inside the coil-wrapped tank
5. The refrigerant reverts back to a liquid after heating the
water and continues to the evaporator for the process to
start again
6. The cycle continues until the set target temperature is
achieved.
7. As water is used in the home, the cycle will restart once
the temperature in the tank has dropped 11 degrees
below the target temperature.
iStore Basics

iStore - Installation Manual - June 2020
7
Specifications
2.1 Dimensions 270L
Dimensions
Height (mm) 1955
Diameter (mm) 640
Height to water inlet (mm) 99
Height to water outlet (mm) 1194
Hot water condensation (mm)
Height to PTR Valve (mm)
Height to Anode 1094
Net weight (Kg) 157
1955
1194
1194
1094
640
99
Unit: mm
HW outlet
HW condensation PTR Valve
Anode
Cold water inlet
Overall height
Overall width
270L iStore
Top View
685

iStore - Installation Manual - June 2020
8
Specifications
2.2 Dimensions 180L
Dimensions
Height (mm) 1957
Diameter (mm) 540
Height to water inlet (mm) 60
Height to water outlet (mm) 1240
Hot water condensation (mm)
Height to PTR Valve (mm)
Height to Anode 1140
Net weight (Kg) 93
1956
1240
1240
1140
540
60
Unit: mm
HW outlet
HW condensation PTR Valve
Anode
Cold water inlet
Overall height
Overall width
180L iStore
Top View 583

iStore - Installation Manual - June 2020
9
Specifications
2.3 Performance Parameters
• Operating water pressure 0.15 to 0.7MPa
• Ambient temperature is -7~50 (compressor)
• The max temperature of water tank is 75o C
• Maximum inlet water pressure is 500kPa
• PTR Valve setting is 850kPa
• ECV Valve setting is 700kPa (if required)
Value 180L 270L
Heating capacity kW 1.92 3.6
Water tank capacity L 180 270
Compressor power input kW 0.47 0.94
Compressor running current A 2.04 5.9
Power supply V 240 240
Compressor number Quantity 1 1
Compressor Type Rotary Scroll
Rated outlet water Temp. C 60 60
Air volume m3/h 700 450
Noise dB(A) 45 @1m 46.6 @ 1m
Water inlet/outlet size inch 3/4 3/4
Auxilary e-heater kW 1.5 1.5
Rated Power Input kW 2.2 3.1
Rated Current Input A 9.2 13
Value 180L 270L
Heating capacity kW 1.92 3.6
Water tank capacity L 180 270
Compressor power input kW 0.47 0.94
Compressor running current A 2.04 5.9
Power supply V 240 240
Compressor number Quantity 1 1
Compressor Type Rotary Scroll
Rated outlet water Temp. C 60 60
Air volume m3/h 700 450
Noise dB(A) 45 @1m 46.6 @ 1m
Water inlet/outlet size inch 3/4 3/4
Auxilary e-heater kW 1.5 1.5
Rated Power Input kW 2.2 3.1
Rated Current Input A 9.2 13
Hot and Cold Water Connections
All plumbing connections must be performed by a licensed plumber in accordance with local authority regulations.
The cold water inlet connection to the storage tank is 3/4 FI. All pipes and valves must be insulated as per the current AS/NZ 3500.4 Section
8.2. The cold water inlet requires the following valve train please refer to system diagram page for correct installation.
• Approved isolating/non return valve
• 500 kPa Pressure Reduction Valve (PRV) valve
• 700 kPa Expansion Control Valve (ECV)
The maximum inlet water pressure rating is 750kPa. Cold water supply pressures exceeding 500kPa a 500kPa Pressure Reduction valve
shall be installed immediately downstream from the Duo valve.
The hot water outlet from the tank is ¾ inch FI. All hot water pipes must be insulated by UV stable & appropriately rated insulation.
Working Range

iStore - Installation Manual - June 2020
10
Safety Features
To prevent unwanted changes to your iStore settings. The Smart Screen will automatically lock after 15 seconds.
If the unit stops and you re start the unit or turn it on by the manual switch, the unit will not start to run again
for approx 3 minutes. This is a protection feature to safeguard the compressor.
In the heating mode the unit will defrost automatically, maximizing the heating eciency
(Lasting 2 - 10 minutes). The fan motor will stop running whilst the unit is defrosting.
In order to use the unit correctly, please operate the unit at ambient temperature of -7º ~ 50º Celsius.
If the water temperature reaches 85º C, the power of unit will be cut o (refer to manual to reset).
An 850kPa, 10kW and 99°C PTR valve is used on the iStore water tank, which is located on the side of the
water tank and is essential for its safe operation. The PTR valve is designed to allow 3-5% of total tank volume
to discharge during heating to allow for hot water expansion. Water may drip from the discharge pipe of the
pressure-relief valve. The discharge pipe must be left open to the atmosphere under all circumstances. PTR
Valve the discharge pipe shall be installed downwards and with discharge pipes in a frost free environment.
Refer page 12 for how to connect. Seal the thread with approved sealant such as Teon tape and screw the
valve into the correct opening and leave the valve outlet pointing downwards. The discharge pipe diameter is
permitted to be run in 15mm copper providing the length of discharge pipe does not exceed 9m.
During normal operation, condensation occurs from the transfer of air across across the evaporator coil. This
process is drawing humidity from the air and creates condensation/water droplets on the coils, which in turn is
captured in the fully moulded condensate tray and discharged through the condensate drain line. In locations
with humidity greater than 80%, up-to 5 litres per day can be expected under normal operating conditions.
Smart Screen Lock
Start up delay protection
Defrost mode
Working conditions
Thermal cut-o saftey device
Condensation
Pressure Temperature Relief Valve (PTR)
DANGER: Failure to operate the relief valve easing gear at least once every six months may result in the water
heater exploding. Continuous leakage of water from the valve may indicate a problem with the water heater.
Autres manuels pour 180L
1
Ce manuel convient aux modèles suivants
1
Table des matières
Manuels Système d'eau populaires d'autres marques

Spirotech
Spirotech SPIROVENT SUPERIOR S250 Manuel utilisateur

Culligan
Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water... Manuel utilisateur

A.O. Smith
A.O. Smith Dura-Max AJH - 1000A - P Manuel utilisateur

Microline
Microline T.F.C.-4 Manuel

Eureka Forbes
Eureka Forbes Aquaguard Select Manuel utilisateur

Cetetherm
Cetetherm AquaEfficiency Manuel utilisateur