Intex ECO5110 Manuel utilisateur

329
PO
(329PO) MODEL ECO5110&6110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 01/22/2021
English
English
OWNER’S MANUAL
Saltwater System with
E.C.O. (Electrocatalytic
Oxidation)
Model ECO5110 & 6110
IMPORTANT
SAFETY RULES
Read, understand, and follow
all instructions carefully before
installing and using this product.
Don’t forget to try these other fine Intex products: Pools, Pool
Accessories, Inflatable Pools and In-Home Toys, Airbeds and
Boats available at fine retailers or visit our website listed below.
Due to a policy of continuous product improvement, Intex
reserves the right to change specifications and appearance,
which may result in updates to the instruction manual without
notice.
IMPORTANT!
DO NOT RETURN PRODUCT TO STORE
To purchase parts and accessories or to obtain non-technical assistance, Visit
www.intexcorp.com
For technical assistance and missing parts call us toll-free (for U.S. and Canadian Residents):
1-800-234-6839
Monday through Friday, 8:30am to 5:00pm Pacific Time 329-*PO-R2-2101
For illustrative purposes only.

(329PO) MODEL ECO5110&6110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 01/22/2021
329
PO
SAVE THESE INSTRUCTIONS
English
Page 2
Warnings............................................................................... 3
Parts References................................................................... 4
Product Specifications......................................................... 5
Setup Instructions................................................................ 6-10
Salt & Pool Water Volumes...................................................11
Intex Pools Salt Table........................................................... 12
Intex Pools Cyanuric Acid Table..........................................13
Intex Pools Operating Time Table........................................14-15
Non-Intex Pools Salt Table...................................................
16
Non-Intex Pools Cyanuric Acid Table................................. 16
Non-Intex Pools Operating Time Table................................16
Operating Instructions......................................................... 17-18
LED Code Chart.................................................................... 19
Maintenance.......................................................................... 20-21
Long Term Storage............................................................... 22
Pool Maintenance and Chemical Definitions..................... 23
Troubleshooting Guide........................................................
24-25
Control Station Replacement..............................................
26
General Aquatic Safety........................................................
26
Limited Warranty................................................................... 27
TABLE OF CONTENTS

(329PO) MODEL ECO5110&6110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 01/22/2021
329
PO
SAVE THESE INSTRUCTIONS
English
Page 3
WARNING
• For Outdoor use only.
• Not to energize or operate the unit if the cell housing is damaged or improperly assembled.
• To reduce the risk of injury, do not permit children to use this product. Always supervise
children and those with disabilities.
• Children must stay away from this product and all electrical cords.
• Assembly and disassembly by adults only.
• Risk of electric shock. Connect only to a grounding type receptacle, this product is provided
with a ground-fault circuit interrupter. If replacement of the plug or cord is needed, use only
identical replacement parts.
• Always unplug this product from the electrical outlet before removing, cleaning, servicing or
making any adjustment to the product.
• The unit is provided with a ground-fault circuit interrupter (GFCI). To test the GFCI, push the
test button. The GFCI should interrupt power. Push the reset button, power should be restored.
If the GFCI fails to operate in this manner. The GFCI is defective. If the GFCI interrupts power
to the pump without the test button being pushed, a ground current is flowing, indicating the
possibility of an electric shock. Do not use this pump. Disconnect the pump and have the
problem corrected by a qualified service representative before using.
• Do not bury the electrical cord. Locate the cord where it will not be damaged by lawn mowers,
hedge trimmers and other equipment.
• To reduce the risk of electric shock, the supply cord cannot be replaced. If the cord is
damaged, the appliance should be replaced immediately.
• To reduce the risk of electric shock, do not use extension cords, timers, plug adaptors or
converter plugs to connect unit to electric supply; provide a properly located outlet.
• Do not attempt to plug in or unplug this product while standing in water or when your hands
are wet.
• Do not use an appliance leakage current interrupter (ALCI) in place of a GFCI since the ALCI
will not protect people.
• Position this product away from the pool, so as to prevent children from climbing on it and
accessing the pool.
• Make sure the electrical parameters indicated on the product correspond to the local mains
voltage before you connect the unit.
• This product is intended to be used only for the purposes described in the manual!
FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN PROPERTY
DAMAGE, ELECTRIC SHOCK, ENTANGLEMENT OR OTHER SERIOUS
INJURY OR DEATH.
IMPORTANT SAFETY RULES
Read, Understand and Follow All Instructions Carefully Before Installing and Using this Product.
READ AND FOLLOW ALL INSTRUCTIONS
For portable Above-Ground-Pools only
This product is for use with storable pools only. Do not use with permanently-installed pools. A
storable pool is constructed so that it is capable of being readily disassembled for storage and
reassembled to its original integrity. A permanently-installed pool is constructed in or on the
ground or in a building such that it cannot be readily disassembled for storage.
To reduce the risk of electric shock the pool must be installed no closer than 6 feet (1.8 m) from
any electrical outlet. Do not place portable appliances closer than 5 feet (1.5 m) from the pool.
These product warnings, instructions and safety rules provided with the product represent some common
risks of water recreation devices and do not cover all instances of risk and danger. Please use common
sense and good judgement when enjoying any water activity.
CAUTION

(329PO) MODEL ECO5110&6110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 01/22/2021
329
PO
SAVE THESE INSTRUCTIONS
English
Page 4
PARTS REFERENCE
Before assembling your product, please take a few minutes to check the contents
and become familiar with all the parts.
NOTE: Drawings for illustration purpose only. Actual product may vary. Not to scale.
When ordering parts, be sure to quote the model number and part numbers.
REF. NO.
DESCRIPTION QTY.
SPARE PART NO.
COMMON
PARTS
PARTS FOR
CONNECTION
TO FILTER
PUMPS WITH
1-1/4” (32MM)
HOSE SIZE
ECO5110 ECO6110
1 ADAPTOR A WITH THREADED COLLAR 1 10849 10849
2 SCREW 2 11519 11519
3 ELECTROLYTIC CELL HOUSING 1 11898 11903
4 E.C.O. ELECTRODE 1 11900 11905
5 TITANIUM ELECTRODE 1 11899 11904
6 FLOW SENSOR 1 11460 11460
7
CONNECTOR HOSE WITH THREADED FITTINGS
1 10720 10720
8THREADED ADAPTOR B 1 10722 10722
9CELL COVER 2 11131 11131
10 ELECTROLYTIC CELL NUT 1 11582 11432
11 L-SHAPE O-RING 2 11228 11228
12 TITANIUM ELECTRODE O-RING 1 11585 11515
13 CONTROL STATION 1 12657 12659
14 TEST STRIPS 1 19635 19635
15 TITANIUM ELECTRODE O-RING 1 11585 11585
16 ELECTROLYTIC CELL NUT 1 11582 11582
10 5 12
3
11
16
8
7
215
16
4
13
9
14

(329PO) MODEL ECO5110&6110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 01/22/2021
329
PO
SAVE THESE INSTRUCTIONS
English
Page 5
PRODUCT SPECIFICATIONS
Hose from
Filter Pump
Flow Sensor
Electronic
Control Station
Electrolytic Cell Hose Returning
Water to Pool
E.C.O.
Electrodes
Model: ECO5110 ECO6110
Power: 110 - 120 Volt AC 110 - 120 Volt AC
Amperage: 0.6 A 1.1 A
Wattage: 65 W 125 W
Ideal Salt Level: 3000 ppm (parts per million) 3000 ppm (parts per million)
E.C.O. Cell Output Current: 500 mA 800 mA
Maximum sodium hypochlorite
output/hour:
5 grams/hour 12 grams/hour
Filter pump minimum flow rate: 700 ~ 3200 gallons/hour
(2650 - 12112 liters/hour)
700 ~ 3200 gallons/hour
(2650 - 12112 liters/hour)
Limited Warranty: see “Limited Warranty”

(329PO) MODEL ECO5110&6110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 01/22/2021
329
PO
SAVE THESE INSTRUCTIONS
English
Page 6
SETUP INSTRUCTIONS
1. Assemble the above-ground-pool (AGP) and its filter pump according to their installation
instructions.
2. Take the Saltwater System and its accessories out of the packaging.
3. Place the Saltwater System in line after the filter pump.
4. Connect the connector hose (7) to the Saltwater System inlet.
Connecting the system to pump and pool with 1-1/4” (32mm) connections/
hoses:
The saltwater system features 1-1/2” (38mm) connections. It is accordingly supplied
with adaptors A (1) and B (8) for connecting to the small 1-1/4” (32mm) diameter
connections/hoses. Install as follows:
Drawing #1
IMPORTANT
• The Saltwater System requires a separate filter pump [700~3200 gph (2650~
12112 lph)] to drive the water and function properly.
• The Saltwater System must be installed as the last piece of pool equipment in the
water return line to the pool as displayed in Drawing #1. This location extends the
life of the titanium plates.
Please visit www.intexcorp.com for the latest instructional video on the
installation and operation of this product.
WATER TO
POOL
WATER FROM
POOL
ID 1-1/4” (32mm)
HOSE
FILTER
PUMP
SWIMMING POOL
ID 1-1/4”
(32mm) HOSE
8
8
7
1
SALTWATER SYSTEM WITH
E.C.O. (ELECTROCATALYTIC
OXIDATION)

(329PO) MODEL ECO5110&6110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 01/22/2021
329
PO
SAVE THESE INSTRUCTIONS
English
Page 7
SETUP INSTRUCTIONS (continued)
1. Go directly to step 2 if your pool is empty. If your above-ground-pool is filled with water,
unscrew the strainer grids from the strainer connectors and insert the black hat-like plugs
into the connectors, before installing the saltwater pool system.
2. Connect the adaptor A (1) to the electrolytic cell (3) outlet as shown in Drawing #1. Tighten
securely.
3. Disconnect the water return hose from the filter pump connection and connect it to the
adaptor A (1) on the Saltwater System with a hose clamp. (see Drawing #1)
4. Connect adaptor B (8) to the connector hose (7). Tighten securely. (see Drawing #1)
5. Connect adaptor B (8) to filter pump outlet (lower connection). Tighten securely.
6. Remove the black hat-like plugs that prevent water from flowing out of the pool. Now, return
the strainer grids to the strainer connectors.
13
7
8
7
8
Filter
Pump

(329PO) MODEL ECO5110&6110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 01/22/2021
329
PO
SAVE THESE INSTRUCTIONS
English
Page 8
SETUP INSTRUCTIONS (continued)
Connecting the system to pump and pool with 1-1/2” (38mm) connections/hoses:
Pump and pool with 1-1/2” (38mm) connections do not require the adaptors A (1) or B (8).
Install as follows:
Drawing #2
1. Go directly to step 2 if your pool is empty. If your above-ground-pool is filled with water,
close the plunger valves before installing the Saltwater System.
2. Disconnect the water return hose from the filter pump connection and connect it to the
Saltwater System outlet.
3. Connect the connector hose (7) to the filter pump outlet connection.
4. Open the plunger valves to allow the water to flow.
FILTER
PUMP
ID 1-1/2” (38mm)
HOSE
ID 1-1/2” (38mm)
HOSE
SALTWATER SYSTEM WITH E.C.O.
(ELECTROCATALYTIC OXIDATION)
SWIMMING POOL
WATER TO
POOL
PLUNGER
VALVE
WATER FROM
POOL
7

(329PO) MODEL ECO5110&6110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 01/22/2021
329
PO
SAVE THESE INSTRUCTIONS
English
Page 9
SETUP INSTRUCTIONS (continued)
Connecting the system to other types of pump (with different type of thread or no
thread):
The Saltwater System can also be adapted to other filter pumps with different thread or those
without a thread on the connection.
Connection to 1-1/4” (32mm) hose:
1. Connect one end of adaptor B (8) to the connector hose (7). Tighten securely.
2. Now, connect the other end of adaptor B (8) to the filter pump outlet. Tighten securely.
Connection to 1-1/2” (38mm) hose with clamp:
1. Connect the connector hose (7) to the filter pump outlet connection with a large hose
clamp. Tighten securely.
ID 1-1/4” (32mm)
CONNECTION
SALTWATER SYSTEM WITH E.C.O.
(ELECTROCATALYTIC OXIDATION)
FILTER
PUMP
78
LARGE HOSE CLAMP
SALTWATER SYSTEM WITH E.C.O.
(ELECTROCATALYTIC OXIDATION)
7
FILTER
PUMP
ID 1-1/2” (38mm)
CONNECTION

(329PO) MODEL ECO5110&6110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 01/22/2021
329
PO
SAVE THESE INSTRUCTIONS
English
Page 10
SETUP INSTRUCTIONS (continued)
Connecting the system to other types of pool
After you have connected the Saltwater System to the pump, connect it to the pool.
This is depicted in Drawings #1 and #2.
Following are the common connection types:
Connection to 1-1/4” (32mm) connectors:
1. Connect the adaptor A (1) to the electrolytic cell (3) outlet. Tighten securely.
2. The adapter A (1) is now fitted to the Saltwater System. The following step is to connect the
water return hose to the adaptor A (1) with a hose clamp.
Connection to 1-1/2” (38mm) connectors without thread:
1. Connect the adaptor A (1) to the electrolytic cell (3) outlet. Tighten securely.
2. With the adaptor A (1) fixed to the Saltwater System, connect the water return hose to the
adaptor, using a large hose clamp.
SALTWATER SYSTEM WITH E.C.O.
(ELECTROCATALYTIC OXIDATION)
HOSE CLAMP
1
ID 1-1/4” (32mm)
HOSE
SALTWATER SYSTEM WITH E.C.O.
(ELECTROCATALYTIC OXIDATION)
LARGE HOSE CLAMP
1
ID 1-1/2” (38mm)
HOSE
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Intex Système d'eau
Manuels Système d'eau populaires d'autres marques

Spirotech
Spirotech SPIROVENT SUPERIOR S250 Manuel utilisateur

Culligan
Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water... Manuel utilisateur

A.O. Smith
A.O. Smith Dura-Max AJH - 1000A - P Manuel utilisateur

Microline
Microline T.F.C.-4 Manuel

Eureka Forbes
Eureka Forbes Aquaguard Select Manuel utilisateur

Cetetherm
Cetetherm AquaEfficiency Manuel utilisateur