International Electronics prox.pad plus Instructions de montage

IEI prox.padTM
plus Access System
Installation/Programming Manual
www.ieib.com prox.pad plus Installation/Programming
Manual
Copyright 2003 Part Number 6105679, Rev. 1.0
International Electronics, Inc.
PPP, D2

For more information, contact:
International Electronics, Inc. © Copyright 2003
427 Turnpike Street International Electronics, Inc.
Canton, MA 02021 U.S.A. All Rights Reserved
Published in U.S.A.
Telephone:
781-821-5566
800- 733-9502 (sales in MA)
800-343-9502 (sales)
Fax: 781-821-4443
Fax
Information
Center: 781-821-0734
Internet: www.ieib.com
PPP, D2

Table of Contents
Chapter 1: Introduction
1.1 About this Manual............................................... 1-1
1.2 Safety Warnings and Cautions.......................... 1-1
1.3 Design Change Disclaimer................................. 1-1
1.4 Reproduction Disclaimer.................................... 1-1
1.5 Technical Support................................................ 1-1
1.6 Warranty................................................................ 1-2
1.7 Items Supplied from the Factory ...................... 1-3
1.8 Items the Installer Must Supply........................ 1-3
1.9 General Description............................................. 1-4
1.9.1 Design Function ............................................ 1-4
1.10 prox.pad plus Operation .................................. 1-5
Chapter 2: Installation
2.1 Installation Configurations................................. 2-1
2.2 Other Installation Considerations..................... 2-2
2.2.1 Power Supply/Current Requirements....... 2-2
2.2.2 Gang Box and Mounting............................. 2-2
2.2.3 Mounting the Unit on Metal....................... 2-2
2.2.4 RF Interference .............................................. 2-2
2.3 Checking the Cables............................................ 2-3
2.4 Mounting the prox.pad plus Unit .................... 2-7
2.4.1 Performing a Wall Mounted Installation.. 2-7
2.4.2 Performing a Glass Mounted Installation. 2-9
2.4.3 Performing a Secure Installation................ 2-11
2.5 Inserting Circuit Boards...................................... 2-15
2.6 Defaulting prox.pad plus Memory................... 2-16
prox.pad plus Install/Program. Manual, PPP, D2 iii

Chapter 3: Wiring
3.1 Wiring the prox.pad plus Unit...........................3-1
3.1.1 Wiring the AUX Relay for Use as Alarm
Shunt .........................................................................3-1
3.1.1.A Wiring the Alarm Shunt Relay...........3-1
3.1.2 Wiring the AUX Relay for Use as Forced
Door...........................................................................3-3
3.1.2.A Wiring the Forced Door Relay ...........3-3
3.1.3 Wiring the AUX Relay for Use as
Propped Door..........................................................3-5
3.1.3.A Wiring the Propped Door Relay........3-5
3.1.4 Wiring the Door Contact Input...................3-7
3.1.5 Wiring the REX Switch (Request to Exit)..3-9
3.1.6 Wiring the Main Relay..................................3-11
3.2 prox.pad plus Communications ........................3-13
3.3 Networking Multiple prox.pad plus Units
Together .......................................................................3-14
3.4 Testing the prox.pad plus...................................3-16
3.4.1 Testing the Controller/Keypad....................3-16
Chapter 4: Programming
4.1 Programming Overview .....................................4-1
4.1.1 Programming from the Keypad..................4-1
4.1.1.A Master Code (User #1) ........................4-1
4.1.1.B Supervisor Code (user #2) ..................4-2
4.1.1.C Master Code and Supervisor Code
Special Features..................................................4-2
4.1.1.D prox.pad plus Default Settings ..........4-3
4.1.1.E Resetting the Master Code and
System Defaults Only .......................................4-5
4.1.1.F Erasing Entire Memory/Resetting
System Defaults..................................................4-6
Table of Contents
iv prox.pad plus Install/Program. Manual, PPP, D2

4.2 Programming Users............................................. 4-7
4.2.1 Adding New or Changing Existing
Codes/Cards ............................................................ 4-7
4.2.2 Programming Code and Card Options .... 4-7
4.2.2 Programming User Types............................ 4-8
4.2.2.A Programming User Data,
Command 50, Full Format .............................. 4-9
4.2.2.B Quick Program Feature....................... 4-10
4.2.2.C Programming Code ONLY Use ........ 4-10
4.2.2.D Programming Code AND Card Use 4-10
4.2.2.E Programming Card ONLY Use ......... 4-11
4.2.2.F Programming Code OR Card............. 4-11
4.2.3 Batch Load Cards by Presentation............. 4-12
4.2.4 Enabling/Disabling Users Command ........ 4-13
4.2.5 Batch Load Cards Manually
(without presentation)........................................... 4-14
4.2.6 Block Delete of Users ................................... 4-15
4.2.7 Deleting Users ............................................... 4-15
4.3 Programming Outputs........................................ 4-16
4.3.1 Changing the Lock Output Time............... 4-16
4.3.2 Assigning Outputs ........................................ 4-16
4.3.3 Setting Propped Door Output Time ......... 4-18
4.3.4 Setting Forced Door Output Time............. 4-18
4.4 Programming Keypad Options and
Parameters................................................................... 4-19
4.4.1 User Lockout Option.................................... 4-19
4.4.1.A Lockout By Location............................ 4-19
4.4.1.B Lockout By Group................................ 4-20
4.4.2 TimeZone/Holiday Features........................ 4-21
4.4.2.A Midnight Crossing TimeZones.......... 4-22
4.4.2.B Holidays ................................................. 4-23
4.4.2.C Daylight Savings Time ........................ 4-23
4.4.2.D Leap Year .............................................. 4-24
Table of Contents
prox.pad plus Install/Program. Manual, PPP, D2 v

4.4.2.E Time/Date Set.........................................4-24
4.4.3 Turning Visual LED/Keypress Indicator
ON/OFF ....................................................................4-24
4.4.4 Turning Audio Keypress Feedback
ON/OFF ....................................................................4-25
4.4.5 Error Lockout .................................................4-26
4.4.6 Timed Anti-Passback.....................................4-27
4.5 Using the Printing Features................................4-29
4.5.1 Selecting Transaction Log Information......4-29
4.5.2 Printing a Transaction Log...........................4-30
4.5.2.A Programming a Transaction Dump
Code .....................................................................4-31
4.5.2.B Printing a Transaction Log
Manually..............................................................4-31
4.5.2.C Erasing a Transaction Log...................4-32
4.5.2.D Printing a Programmed Users List....4-32
4.6 Programming Commands ..................................4-34
Chapter 5: Troubleshooting
5.1 Before Calling IEI .................................................5-1
5.2 Flow Charts ...........................................................5-4
5.3 Performing Power Supply Integrity Test.........5-6
5.4 Correcting Possible Water Problems.................5-9
5.4.1 Silicone.............................................................5-9
5.4.2 Wire Run .........................................................5-9
Chapter 6: Miscellaneous
Information
6.1 Customer Service Policy......................................6-1
6.2 RMA Policy ............................................................6-2
Table of Contents
vi prox.pad plus Install/Program. Manual, PPP, D2

List of Illustrations
Figure 2-1 prox.pad plus Wiring Harness.........2-3
Figure 2-2 Identifying Pin Connectors ..............2-4
Figure 2-3 Performing a Wall Mounted I
nstallation.............................................2-8
Figure 2-4 Performing a Glass Mounted
Installation ...........................................2-10
Figure 2-5 Performing a Secure Installation .....2-12
Figure 2-6 Removing/Inserting Printed Circuit
Board ....................................................2-15
Figure 2-7 Program Button Location on Main
Circuit Board .......................................2-17
Figure 3-1 Wiring the Aux Relay for Alarm
Shunt Operation.................................3-2
Figure 3-2 Wiring the Aux Relay for Forced
Door Alarm..........................................3-4
Figure 3-3 Wiring the Aux Relay for Propped
Door Alarm..........................................3-6
Figure 3-4 Wiring the Door Contact Input .......3-8
Figure 3-5 Wiring the REX Switch .....................3-10
Figure 3-6 Electric Strike (Fail Secure)
Wiring Diagram..................................3-11
Figure 3-7 MagLock (Fail Safe) Wiring
Diagram................................................3-12
Figure 3-8 Connecting the prox.pad plus to a
PC COM Port......................................3-13
Figure 3-9 Connecting the prox.pad plus to a
Network ...............................................3-14
Figure 3-10 Networking Multiple prox.pad
plus Units Together ...........................3-15
prox.pad plus Install/Program. Manual, PPP, D2 vii

List of Tables
Table 1-1 prox.pad plus Specifications ............ 1-6
Table 2-1 prox.pad plus Pin Connections ....... 2-5
Table 2-2 IEI-Supplied Parts/Optional Items.. 2-6
Table 4-1 prox.pad plus Default Settings ........ 4-3
Table 4-2 LED Indicators/Sounder
Operations........................................... 4-4
Table 4-3 prox.pad plus User Types ................ 4-8
Table 5-1 Troubleshooting Chart...................... 5-2
List of Illustrations/List of Tables
viii prox.pad plus Install/Program. Manual, PPP, D2

Chapter 1:
Introduction
1.1 About this
Manual
This manual is designed for installers of the Interna-
tional Electronics prox.pad plus Access System.
1.2 Safety
Warnings and
Cautions
When handling the main printed circuit board, to
guard against possible static discharges, touch a
grounded object BEFORE touching the prox.pad plus
unit. Static shock can render the product unusable.
1.3 Design
Change
Disclaimer
Due to design changes and product improvements,
information in this manual is subject to change without
notice. IEI assumes no responsibility for any errors that
may appear in this manual.
1.4 Reproduction
Disclaimer
Neither this manual nor any part of it may be repro-
duced, photocopied, or electronically transmitted in
any way without the written permission of IEI.
1.5 Technical
Support
Should you experience any difficulty installing the
prox.pad plus unit, please contact your IEI repre-
sentative, or IEI at the number listed on page ii. Before
calling IEI for installation assistance, refer to Chapter
5, Troubleshooting. This chapter includes a list of com-
mon system problems, possible causes, and corrective
actions plus easy-to-use diagnostic flow charts.
To contact IEI’s Technical Support department, call
1-800-343-9502 between 8:00 a.m. - 7:00 p.m. (Eastern
Standard Time), Monday through Friday. Questions
can also be submitted through our website at
www.ieib.com. You can also download an electronic
version of this manual from this site.
prox.pad plus Install/Program. Manual, PPP, D2 1-1

1.6 Warranty International Electronics Inc. (IEI) warrants its prod-
ucts to be free from defects in material and workman-
ship when they have been installed in accordance with
the manufacturer’s instructions and have not been
modified or tampered with. IEI does not assume any
responsibility for damage or injury to person or prop-
erty due to improper care, storage, handling, abuse,
misuse,normalwearandtear,oranactofGod.
IEI’s sole responsibility is limited to the repair (at IEI’s
option) or the replacement of the defective product or
part when sent to IEI’s facility (freight and insurance
charges prepaid) after obtaining IEI’s Return Material
Authorization. IEI will not be liable to the purchaser
or any one else for incidental or consequential dam-
ages arising from any defect in, or malfunction of, its
products.
Except as stated above, IEI makes no warranties, either
expressed or implied, as to any matter whatsoever,
including, and without limitation to, the condition of
its products, their merchantability, or fitness for any
particular purpose.
Warranty Periods Are:
1 Year PowerKey
2 Years Door Gard & Secured Series
Products
2 Years prox.pad and prox.pad plus
2 Years LS Series
2 Years Glass Break
5 Years ‘e’ Series Keypads
All products have date code labeling to determine the
warranty period. A 90-day grace period is added to all
products to account for shelf life.
Chapter 1: Introduction 1.6 Warranty
1-2 prox.pad plus Install/Program. Manual, PPP, D2
Autres manuels pour prox.pad plus
1
Table des matières