IntelligentAg Engage Zone Control Manuel

OPERATOR’S GUIDE
Document revision: 1.1
Last revised: February 17, 2019

Engage Zone Control Operator’s Guide
600890-000059, rev 1.1 Page 2 of 25
Engage Zone Control
Operator’s Guide
© 2018-19 Intelligent Agricultural Solutions All Rights Reserved.
Engage Zone Control Operator’s Guide. All content within is copyrighted by Intelligent
Agricultural Solutions, and may not be reprinted without permission.
The content of this manual is furnished for informational use only, is subject to change without
notice, and should not be construed as a commitment by Intelligent Agricultural Solutions.
Intelligent Agricultural Solutions assumes no responsibility or liability for any errors or
inaccuracies that may appear in the content contained in this guide.
U.S. Patent Application #15/639497, and foreign patents pending. Intelligent Agricultural
Solutions, Engage Zone Control, Intelligent Agricultural Solutions, Intelligent Ag, Intelligent Ag
Monitoring Solutions, IAS, and the IAS logo are trademarks or registered trademarks of
Intelligent Agricultural Solutions.
Intelligent Agricultural Solutions, 1810 NDSU Research Circle North, Fargo, ND 58102 USA.
Visit us on the web at www.intelligentag.com

Engage Zone Control Operator’s Guide
600890-000059, rev 1.1 Page 3 of 25
Table of Contents
1. About Engage Zone Control ..................................................................................................5
2. Connecting the System to the 2630.......................................................................................5
3. Configuring John Deere Settings...........................................................................................6
4. Configuring Engage Zone Control Application.....................................................................12
4.1. Navigating to Intelligent Ag Section Settings.............................................................12
4.2. Modifying Intelligent Ag Section Settings ..................................................................13
4.3. Configuring Serial Numbers ......................................................................................15
4.4. Editing JD Section Control settings ...........................................................................16
4.5. Refining Times ..........................................................................................................17
5. Using the System.................................................................................................................18
5.1. Monitoring Mapping...................................................................................................18
5.2. Intentionally Overseeding..........................................................................................18
5.3. Manually Closing or Opening a Section ....................................................................18
5.4. Viewing Covered and Saved Area ............................................................................19
5.5. Updating Motor Controllers .......................................................................................19
6. Viewing Diagnostics.............................................................................................................20
7. Cleaning and Storage ..........................................................................................................22
8. Troubleshooting ...................................................................................................................22
Common Issues ........................................................................................................22
8.1. 22
Error Messages .........................................................................................................24
8.2. 24
List of Figures
Figure 1: Intelligent Ag settings screen.........................................................................................5
Figure 2: JD Main settings screen ................................................................................................6
Figure 3: JD Resources settings...................................................................................................7
Figure 4: JD Equipment - Machine settings ..................................................................................7
Figure 5: Equipment - Implement settings ....................................................................................8
Figure 6: JD Section Control settings ...........................................................................................9
Figure 7: JD documentation settings ..........................................................................................10
Figure 8: JD Boundaries settings................................................................................................11
Figure 9: Intelligent Ag Configuration Summary screen .............................................................12
Figure 10: Engage Zone Control unit gate numbering................................................................13
Figure 11: Standard section ordering..........................................................................................13
Figure 12: Section ordering with sections off ..............................................................................13
Figure 13: Section ordering with two gates mapped to one section ...........................................14
Figure 14: Intelligent Ag time of flight compensation ..................................................................14
Figure 15: Intelligent Ag Serial Number Configuration settings screen ......................................15
Figure 16: JD Section Control On/Off settings screen ................................................................16
Figure 17: JD Section Control screen .........................................................................................18
Figure 18: Manually closing or opening a section.......................................................................18
Figure 19: Motor controller update screen ..................................................................................19
Figure 20: Intelligent Ag Gate Diagnostics screen......................................................................20

Engage Zone Control Operator’s Guide
600890-000059, rev 1.1 Page 4 of 25
Record of Revision
Revision
Number Change Description Revision
Date Inserted By
0.1 Prototype release 9/01/17 AAL
1.0 Initial release 1/29/18 AAL
1.1 Updated to include new configuration best
practices, readability improvements. 2/18/19 AAL
Related Documentation
Document Number Document Title
600840-000043 Engage Zone Control Installation Guide
600840-000047 Engage Zone Control Maintenance Manual

About Engage Zone Control Engage Zone Control Operator’s Guide
600890-000059, rev 1.1 Page 5 of 25
1. About Engage Zone Control
Engage Zone Control is a retrofit section control system for John Deere 1910 air carts using
John Deere 2630 displays. The system communicates with an air seeder's existing GPS
mapping system and prevents overlap by opening and closing up to eight sections per toolbar.
2. Connecting the System to the 2630
IMPORTANT:If power is disconnected from the 2630, disconnect and reconnect power to the
gateway.
Engage Zone Control must be activated and enabled in the IAS VT application in order to
enable zone control. Section Control must be activated and enabled on the 2630 in order to
properly operate Engage Zone Control. If you don't have section control activated on your 2630,
contact your dealer.
To enable Engage Zone Control, complete the steps below.
1. Tap in the lower right corner of the 2630 screen.
2. Tap Intelligent Ag.
3. Tap Configure.
4. Tap Settings.
5. Scroll to the bottom of the screen. Make sure that the Enabled box next to Engage
Zone Control is checked.
Figure 1: Intelligent Ag settings screen

Configuring John Deere Settings Engage Zone Control Operator’s Guide
600890-000059, rev 1.1 Page 6 of 25
3. Configuring John Deere Settings
Before configuring Zone Control settings, make sure that the John Deere settings listed below
are correctly configured.
1. Navigate to the Setup screen:
a. Tap in the lower right corner.
b. Tap GS3 (GreenStar).
c. Tap in the upper right corner.
d. Add a check mark the following boxes: Resources, Machine, Implement,
Documentation, and Section Control. It is okay if other boxes are automatically
checked by default.
e. Tap Accept.
Figure 2: JD Main settings screen

Configuring John Deere Settings Engage Zone Control Operator’s Guide
600890-000059, rev 1.1 Page 7 of 25
2. Modify Resources settings.
a. Ensure that a value is selected for all items with a red asterisk.
b. Tap to continue.
Figure 3: JD Resources settings
3. Modify Equipment - Machine settings.
a. Ensure that a value is selected for all items with a red asterisk.
b. Tap to continue.
Figure 4: JD Equipment - Machine settings

Configuring John Deere Settings Engage Zone Control Operator’s Guide
600890-000059, rev 1.1 Page 8 of 25
4. Modify Equipment - Implement settings.
a. Ensure that a value is selected for all items with a red asterisk.
b. Tap to continue.
Figure 5: Equipment - Implement settings

Configuring John Deere Settings Engage Zone Control Operator’s Guide
600890-000059, rev 1.1 Page 9 of 25
5. Modify Section Control settings.
a. Ensure that Section Control Master and any boxes below it have checkmarks.
b. Modify overlap settings
i. Tap Overlap Settings.
ii. Select % Overlap for the Exterior Boundaries, Interior Boundaries, and
Coverage.
iii. Type 102 for each percentage.
iv. Tap Accept.
c. Tap to continue.
Figure 6: JD Section Control settings

Configuring John Deere Settings Engage Zone Control Operator’s Guide
600890-000059, rev 1.1 Page 10 of 25
6. Modify Documentation settings.
a. Ensure that a value is selected for items with a red asterisk.
b. Tap to save the settings.
Figure 7: JD documentation settings
IMPORTANT: To modify Documentation settings after initial configuration, you must
disable Zone Control in the Gates page. Refer to Section 5.3 for instructions to navigate
to the Gates page, then uncheck Zone Control Enabled.
Unchecking this disables the control and mapping of the system. Only uncheck this if
you want to change documentation settings in the 2630. Re-check it if you want to use
mapping and section control again.