Intelbras VP 5311 MW Pet Manuel utilisateur

User manual
IVP 5311 MW Pet
English

IVP 5311 MW Pet
Passive infrared sensor
Congratulations, you have just purchased a product with Intelbras quality and safety.
The IVP 5311 MW Pet passive infrared sensor has passive infrared and microwave detection technology, adopting advanced
signal analysis technology, which can prevent false triggering in dangerous environments. This sensor is intended for indoor
and semi-open environments.

Care and safety
» LGPD – Data processing by Intelbras: Intelbras does not access, transfer, capture or perform any type of processing of
personal data from this product.
» Follow all instructions in the manual for assembling and installing the product;
» Fix the sensor on stable surfaces, where there are no vibrations;
» This sensor is intended for closed and semi-open environments;
Semiaberto Fechado Externo
Semi-open Closed External
» Do not use the sensor in areas with sudden changes in temperature, such as near air conditioners and heaters, fans,
refrigerators and ovens. Do not expose the sensor to direct or reected sunlight;
» Do not install the sensor facing windows and glass doors;
» Do not touch the surface of the infrared (PIR) sensor. If necessary, use a cleaning cloth;
» The recommended maximum installation height is 2.20 m, do not exceed it;
» Do not place objects in front of the sensor. To ensure the detection area, avoid curtains, screens, screens, or any object
that may interfere with its coverage area;
» For the use of the articulator, we recommend that the installation be carried out by a professional installer, as its incorrect
use could impair the Pet function and the sensor coverage angle;
» The sensor must be installed where a possible intruder can be easily detected, that is, where it makes transverse move-
ments to the detection beams (see the gure below);
X

» The
Pet
function is intended for crawling animals weighing up to 20 kg. If the animal is on top of a bench, for example,
the
Pet
function can be canceled.
Note: before starting the installation, it is necessary to dene the height at which the sensor will be positioned, which can
vary from 1.8 to 2.2 m. If the sensor is installed at a height of less than 1.8 m or is tilted downwards, the Pet function will be
compromised.
Scan
8 (m)
6
4
2
0
2
4
6
8
0 2 4 6 8
10
12 (m)
Upper view
Detection range
1.2 4 6 8 10 12m
1.8 ~2.20m
1,8 ~ 2,20 m
Side view

Summary
1. Technical specications 6
2. Features 6
3. Product 7
4. Installation 7
4.1. Microwave sensitivity adjustment ...............................................................9
4.2. Operating mode settings ....................................................................10
4.3. Jumper J. LED ..................................................................................... 11
4.4. Jumper J. Pulso ...............................................................................11
4.5. Jumper SENS ....................................................................................11
4.6. Jumper Relé..............................................................................11
4.7. Jumper Mode.............................................................................12
4.8. Completion of the process ...................................................................12
5. Operation 13
6. Test 13
7. Homologation 14
Warranty term 15

6
1. Technical specications
Operating voltage 9 ~16 Vdc
Operating current 38 mA
Detection angle 90°
Detection range (PIR and MW) 12 meters
Detection method Microwave and PIR (AND)
Animal immunity Up to 20 kg
Microwave frequency 10.525 GHz
Sensitivity (J. Pulse)
1- High sensitivity
2- Sensitivity (factory default)
3- Medium sensitivity
4- Low sensitivity
Sensitivity (J. SENS)
1- High sensitivity
2- Medium sensitivity
3- Sensitivity (factory default)
4- Low sensitivity
5- Minimum sensitivity
Anti-violation front tamper
Indicator LEDs
Yellow (PIR)
Red (MW)
Blue (Alarm)
Maximum startup time 80 seconds
Relay opening time 3 seconds
Recommended installation height 2.1 meters
Operating Temperature -10 °C ~ +50 °C
Relay output NA /NF
Dimensions (W × H × D) 55 × 140 × 60 mm
2. Features
» Microcontrolled sensor.
» Anti-camouage technology.
» Microwave sensitivity adjustment.
» PIR pulse and sensitivity adjustment.
» Automatic real-time temperature compensation.
» Immunity to white light up to 20,000 lux.
» High immunity to RFI/EMI.
» Highly effective algorithm against false triggering.
» Pet immunity up to 20 kg.
» Tamper key for lower front cover.
» Quick connect connector.
» Ease of installation.

7
3. Product
1P 2P 3P 4P
LD1
LD2
LD3
TAMPER ALARME
RELÉ
MODO
21
SENS.
J. LEDS
1
2
3
4
5
6
7
8
99
11
12
13
14
15
16 17 18
19
22
20
21
10
1. Top front cover
2. Fresnel lens
3. Lower front cover
4. Hole for xing the bottom cover
5. Basis
6. Oblong for wall mounting
7. Holes for mounting bracket
8. Lacquer for wall installation
9. Seals for corner installation
10. Lacquer for cable passage
11. Microwave module
12. Jumper SENS
13. MODE jumper (AND and anti-stealth
14. Jumper Relay (NO / NC)
15. Tamper switch
16. Jumper WRIST
17. Connection terminals
18. Microwave adjustment trimpot
19. LEDs
20. Piro senor
21. Jumper J. LEDs
22. LED setting microwave
4.Installation
» Before starting the installation, it is necessary to dene the height at which the sensor will be positioned, which can vary
from 1.8 to 2.2 m;
» Do not install sensors that have microwave technology close to each other, as there may be interference between them;
18m
1.8 a 2.2m
» Microwave sensitivity adjustment should be done according to each environment;
» For installation using the articulator, make sure that both the sensor and the support are well xed at the installation site
to avoid changes in the product’s detection angle. Incorrect use of the articulator can alter the sensor’s detection area,
creating blind spots and impairing operating efciency;
» If the sensor is installed at an angle, its detection range and
Pet
function may be impaired in such a way as to cancel
the function.

8
To install the sensor, follow the procedure below:
1. Remove the lower front cover;
1P 2P 3P 4P TAMPER ALARME
2. Route the wiring through the cable knockouts located on the back cover of the sensor.
Note: use a tool to drill the hole in the indicated location and to facilitate the installation, use the recesses in the rear cover
to pass the cables.
1P 2P 3P 4P TAMPER ALARME 1P 2P 3P 4P TAMPER ALARME
Passagem de
cabo
Passage of
cables

9
3. Connect the connecting cables to the sensor terminals and install them in the place to be protected. For installation
directly on the wall or on the edge of the wall, break the sealing waxes indicated for the furos on the rear xing cover.
Note: for installation directly on the wall, use the oblong located on the back of the product. Use a parafuso with dimen-
sions 6×20 mm, executing the procedure to follow. Fix the cover 1 on the wall and t the oblong so that the sensor is rm.
Using the hole below two connectors, place the cover 2 for total xation of the sensor.
Oblongo
Parafuso 1
Encaixe a cabeça do parafuso
na cavidade do oblongo
Lacre
Parafuso 2
Montado na parede Montado no canto da parede
1P 2P 3P 4P TAMPER ALARME
Wall mounted Wall mounted corner
Screw 1
Screw 2 Sealing
Sealing Sealing
Coloque la cabeza del
tornillo en el oricio del
oblongo
4. Make the settings on the sensor following the directions.
4.1. Microwave sensitivity adjustment
The trimpot allows you to adjust the sensitivity of the microwave. Turning the trimpot in a non-clockwise direction
increases the sensitivity and consequently the distance that the microwave is capable of detecting movements. Rotating
counterclockwise or microwave is less sensitive.
Note:
it is highly recommended to adjust the sensitivity of the microwaves so that the detection occurs only in the
environment where the sensor is installed.This technology is capable of detecting movements through a wall, for example.
0%
≅1M
25%
≅5M
50%
≅12M
75%
≅15M
100%
≅18M
12m
12m
12m
12m
12m
12m
6m
3m
Área que se quer proteger
In gure 1 of the example above we have the area that we want to protect. Figures 5 and 6 indicate that the adjustment
of the trimpot exceeds the limits of the environment to be protected. In this way, the microwave will detect movements on
the external side of the desired area.

10
To facilitate the adjustment of the microwave coverage, adjust the trimpot in an anti-clockwise direction (less sensitive) and
walk in the environment that you want to protect. Observe the motion detection of the sensor. If necessary, increase the
sensitivity (clockwise). Repeat this process until the sensor protects only the environment where it is installed.
The gure below shows a reference range of detection of the microwave channel.
Microwave reach
Trimpot position Maximum distance (meters)
0%
25%
50%
75%
100%
0% - up to 1 metro
25% - up to 5 metros
50% - up to 12 metros
75% - up to 15 metros
100% - up to 18 metros
1P 2P 3P 4P TAMPER ALARME
Factory default: 50%
Microwave Adjustment LED The Microwave Adjustment LED is a way to signal microwave detection. Therefore, when
performing the sensitivity adjustment, walk across the entire area you want to protect, observing if the LED will light up.
4.2. Operating mode settings
Note: to perform the Mode, Relay and LED sensitivity adjustments, it is necessary to open the front cover of the sensor,
as shown in the following gures.
Insert a screwdriver into the side of the top slot on the cover, then push the cover forward.
1P 2P 3P 4P
LD1
LD2
LD3
TAMPER ALARME
RELÉ
MODO
21
SENS.
J. LEDS
RELÉ
MODO
21
SENS.
J. LEDS
1P 2P 3P 4P
J. PULSO
Table des matières
Autres manuels Intelbras Capteur de sécurité

Intelbras
Intelbras IVP 2000 SF Manuel utilisateur

Intelbras
Intelbras IVP 8000 EX Manuel utilisateur

Intelbras
Intelbras IVP 4101 PET Manuel utilisateur

Intelbras
Intelbras XAS 8000 Manuel utilisateur

Intelbras
Intelbras IVP 4101 PET Manuel utilisateur

Intelbras
Intelbras IVP 1000 PET Manuel utilisateur

Intelbras
Intelbras IVP 1000 PET Manuel utilisateur

Intelbras
Intelbras IVP 8000 EX Manuel utilisateur

Intelbras
Intelbras IVP 3000 PET Manuel utilisateur