Intel SSR316MJ2 Manuel utilisateur

Intel®Storage System SSR316MJ2
Power Distribution Module (FMJPDB)
Installation Guide
Order Number: C75952-002

Disclaimer
Information in this document is provided in connection with Intel®products. No license, express or implied, by estoppel or
otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions
of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating
to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability,
or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or
authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of
the Intel product could create a situation where personal injury or death may occur. Intel may make changes to
specifications and product descriptions at any time, without notice.
Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries.
*Other names and brands may be claimed as the property of others.
Copyright ©2004 - 2005 Intel Corporation. All Rights Reserved.

iii Intel®Storage System SSR316MJ2 Power Distribution Module
Important Safety Instructions
Important Safety Instructions
Read all caution and safety statements in this document before performing any of the instructions.
See Intel Server Boards and Server Chassis Safety Information at
http://support.intel.com/support/motherboards/server/sb/CS-010770.htm.
Wichtige Sicherheitshinweise
Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor Sie eine
der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-
Serverplatinen und -Servergehäusen unter
http://support.intel.com/support/motherboards/server/sb/CS-010770.htm.
重要安全指导
在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。
和/或http://support.intel.com/support/motherboards/server/sb/CS-010770.htm 上的
Intel
Server Boards and Server Chassis Safety Information
(《Intel
服务器主板与服务器机箱安全信息》)。
Consignes de sécurité
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document
avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety
Information rendez-vous sur le site http://support.intel.com/support/motherboards/server/sb/CS-
010770.htm.
Instrucciones de seguridad importantes
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar
cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en
http://support.intel.com/support/motherboards/server/sb/CS-010770.htm.

Intel®Storage System SSR316MJ2 Power Distribution Module iv
WARNINGS
Storage system power on/off: The push-button on/off power switch on the
front panel of the storage system does not turn off the AC power. To remove
AC power from the storage system, you must unplug the AC power cord
from either the power supply or wall outlet.
Hazardous conditions—power supply: Hazardous voltage, current, and
energy levels are present inside the power supply enclosure. There are no
user-serviceable parts inside the power supply; servicing should only be done
by technically qualified personnel.
Hazardous conditions—devices and cables: Hazardous electrical
conditions may be present on power, telephone, and communication cables.
Turn off the storage system and disconnect telecommunications systems,
networks, modems, and the power cord attached to the storage system before
opening it. Failure to do so can result in personal injury or equipment
damage.
Avoid injury: Lifting the storage system chassis and attaching it to the rack
is a two-person job. If needed, use an appropriate lifting device. A fully
loaded Intel®Storage System SSR316MJ2 weighs approximately 31.8 kg
(70 lbs.).
CAUTIONS
Temperature: The operating temperature of the storage system, when
installed in an equipment rack, must not go below 5° C (41° F) or rise above
35° C (95° F). Extreme fluctuations in temperature can cause a variety of
problems in the storage system.
Ventilation: The equipment rack must provide sufficient airflow to the front
of the storage system to maintain proper cooling. It must also include
ventilation sufficient to exhaust a maximum of 1900 BTUs per hour for a
fully loaded Intel®Storage System SSR316MJ2.

v Intel®Storage System SSR316MJ2 Power Distribution Module
Contents
About the Power Distribution Module............................................................... 7
Contents.................................................................................................................................. 7
Power Distribution Module Installation Procedures........................................ 8
Required Tools........................................................................................................................ 8
Power Down System and Remove Chassis Cover ................................................................. 8
Un-seat Power Supplies..........................................................................................................9
Remove Fan Assembly Screws ............................................................................................ 10
Disconnect Fan Cables ......................................................................................................... 11
Remove Fan Assembly ......................................................................................................... 12
Cut Cable Ties and Remove DIMM ...................................................................................... 13
Disconnect Power Distribution Module Cables ..................................................................... 14
Disconnect Cables and Remove Power Distribution Module................................................ 15
Install New Power Distribution Module.................................................................................. 16
Connect Cables and Install DIMM......................................................................................... 17
Connect Power Distribution Module Cables.......................................................................... 18
Install Fan Assembly............................................................................................................. 19
Attach Fan Assembly ............................................................................................................ 20
Connect System Fan Cables ................................................................................................ 21
Seat Power Supplies.............................................................................................................22
Finishing Up .......................................................................................................................... 23
Figures
Figure 1. Removing Chassis Cover ........................................................................................ 8
Figure 2. Un-seating the Power Supplies................................................................................ 9
Figure 3. Removing System Fan Assembly Screws ............................................................. 10
Figure 4. Disconnecting System Fan Cables ........................................................................ 11
Figure 5. Removing System Fan Assembly .......................................................................... 12
Figure 6. Cutting Cable Ties and Removing DIMM............................................................... 13
Figure 7. Disconnecting Power Distribution Module Cables ................................................. 14
Figure 8. Remove Power Distribution Module from System ................................................. 15
Figure 9. Installing the Power Distribution Module................................................................ 16
Figure 10. Connecting Cables and Installing DIMM.............................................................. 17
Figure 11. Connecting Power Distribution Module Cables.................................................... 18
Figure 12. Installing System Fan Assembly .......................................................................... 19
Figure 13. Attaching System Fan Assembly ......................................................................... 20
Figure 14. Connecting System Fan Cables .......................................................................... 21
Figure 15. Seating the Power Supplies................................................................................. 22
Figure 16. Installing the Chassis Cover ................................................................................ 23


Intel®Storage System SSR316MJ2 Power Distribution Module 7
About the Power Distribution Module
Enclosed is your new Intel®FMJPDB Power Distribution Module. The FMJPDB Power
Distribution Module is installed into the storage system directly behind the backplane board and the
backplane fan assembly, in front of the power supply.
This document describes how to install the FMJPDB Power Distribution Module into the Intel®
Storage System SSR316MJ2.
Contents
Intel®FMJPDB Power Distribution Module

8 Intel®Storage System SSR316MJ2 Power Distribution Module
Power Distribution Module Installation
Procedures
Required Tools
Cross-head (Number 1 size Phillips*) screwdriver, with a maximum length of 4 inches
Wire-cutter
Power Down System and Remove Chassis Cover
1. Review the safety information and warnings at the beginning of this guide.
2. Power down your Intel® Storage System Console. See letter “A” in Figure 1.
3. Remove both AC power cords from the AC power inputs at the rear of your storage system.
See letter “B” in Figure 1.
4. Loosen the two thumb screws at the rear of the chassis cover. See letter “C” in Figure 1.
5. Facing the front of the chassis, push the top cover rearward, and then lift it up to remove it. See
letter “D” in Figure 1.
A
D
B
C
C
TP01797
Figure 1. Removing Chassis Cover

Intel®Storage System SSR316MJ2 Power Distribution Module 9
Un-seat Power Supplies
1. For each power supply, press the latch the right side of the power supply module. See letter “A”
in Figure 2.
2. While pressing the latch, use the handle to pull the power supply out about one inch. See letter
“B” in Figure 2. It is not necessary to completely remove the power supply modules from the
bays.
TP01880
A
B
Figure 2. Un-seating the Power Supplies

10 Intel®Storage System SSR316MJ2 Power Distribution Module
Remove Fan Assembly Screws
Use a Number 1 size Phillips* screwdriver to remove the screw on each side of the system. See
letter “A” in Figure 3. These screws hold the system fan assembly in place. These screws will be re-
installed later.
A
TP01800
Figure 3. Removing System Fan Assembly Screws
Autres manuels pour SSR316MJ2
6
Table des matières
Autres manuels Intel Serveur de stockage réseau

Intel
Intel SS4200-E - Entry Storage System NAS Server Manuel utilisateur

Intel
Intel SS4000-E - Entry Storage System NAS Server Manuel utilisateur

Intel
Intel SSR212MC2 - Storage Server Hard Drive Array Manuel utilisateur

Intel
Intel SS4200-E - Entry Storage System NAS Server Manuel utilisateur

Intel
Intel SSR212MC2R Manuel utilisateur
Manuels Serveur de stockage réseau populaires d'autres marques

HP
HP NetStorage 6000 Manuel utilisateur

Seagate
Seagate U10 ST320423A Manuel utilisateur

Synology
Synology RackStation RS816 Manuel

D-Link
D-Link ShareCenter Pro DNS-1200-05 Manuel utilisateur

Avid Technology
Avid Technology VideoRAID ST Guide de sécurité

Western Digital
Western Digital My Cloud Home Duo Manuel utilisateur