8. Plug the power cord for the pump-motor into the back of
the master switch box located on the lower right front of
the sink.
9. Plug the cord from the master switch box into any
standard grounded, 110 VAC, 60 Hertz, fused power
source. Warning, do not turn the master switch on until
the solvent has been added to the solvent reservoir
barrel; damage may result to the pump.
10. Add the solvent to the solvent reservoir barrel by pouring
it into the partswasher. The reservoir barrel should be
approximately 2/3/full.
11. Turn the master power switch on (Figure 6) and verify that
the light and pump come on. Check for leaks at all hose
fittings and filters. If leaks are detected, shut off master
power switch and correct. Verify that the solvent flows
into both the goose neck and flow thru cleaning brush by
changing the valve at the base of the goose neck in the
bottom of the sink. Always run pump at least 45 minutes
each day.
SERVICING:
Figure 5
Figure 6
Routine maintenance and servicing of the EDGE TEK™ Partswasher units is a very simple
and can be normally accomplished within five minutes per unit. It is suggested that routine
maintenance be accomplished at fixed intervals such as once per month. At this schedule
time, the following should be accomplished.
1. Turn partswasher off.
2. Visually inspect exposed electrical wiring for damage. Repair ifrequired.
3. Verify that works light and pump-motor are securely plugged in. Verify that the
partswasher primary power cord is securely pluggedin.
4. Remove partswasher strainer and observe solvent level in the barrel. Add solvent
so level is approximately two-thirds (2/3) of the barrel. DO NOT OVER FILL.
Replace parts washer strainer.
5. Remove pre-filter canister. Pour excess solvent into the partswasher. Remove filter
element. If stainless steel element is used, remove debris from the element and
canister into the satellite collection drum. If Resin element is used, remove and set
inside of partswasher to drain. Replace cleaned stainless steel element or new
Resin element into canister and screw canister on filter head. DO NOT OVER
TIGHTEN.