IMC MISTRAL TC60 Guide de l'utilisateur

Page | 1
Installation, Operating and Servicing
Instructions
A34/108 R1 ECN 4825 October 2022
MISTRAL TC60 BOTTLE COOLER
Please make a note of your product details for
future use:
Date Purchased: _________________________
Model Number: __________________________
Serial Number: __________________________
Dealer: ________________________________
________________________________
_______

Page | 2
CONTENTS
WARRANTY ....................................................................................................... 3
DELIVERY.......................................................................................................... 3
INTODUCTION .................................................................................................. 3
INSTALLATION .................................................................................................. 5
TURNING LED LIGHTS ON-OFF ...................................................................... 6
REVERSING DIRECTION OF DOOR ................................................................ 7
ELECTRICITY SUPPLY CONNECTION ............................................................ 9
COMMISSIONING ............................................................................................. 9
CHANGING THE CONTROLLER SET POINT ................................................. 10
USING YOUR BOTTLE COOLER .................................................................... 10
CLEANING ....................................................................................................... 11
CHANGING SHELF POSITION ....................................................................... 11
MAINTENANCE ............................................................................................... 12
do’s and don’ts ................................................................................................. 13
END OF LIFE DISPOSAL ................................................................................ 14
MATERIAL CONTENT ..................................................................................... 14
SPARE PARTS LIST ........................................................................................ 15
ORDERING SPARE PARTS ............................................................................ 16
FURTHER INFORMATION .............................................................................. 16

Page | 3
WARRANTY
These bottle coolers are guaranteed by Lincat/IMC for 2 years from the date of
purchase from Lincat/IMC, or from one of its stockists, dealers or distributors.
The guarantee is limited to the replacement of faulty parts or products and
excludes any consequential loss or expense incurred by the purchaser. Defects
which arise from faulty installation, inadequate maintenance, incorrect use,
connection to the wrong electricity supply, or fair wear and tear, are not covered
by the guarantee.
The guarantee applies in this form to installations within the United Kingdom.
Export units carry 2 years “parts only” warranty.
Please observe these instructions carefully.
DELIVERY
The packaged machine consists of:
TC60 Bottle Cooler containing:
Shelf (Full size)
Shelf clips
Sets of keys
5
20
2
Instruction Booklet 1
Please notify both the carrier and the supplier within 24 hours of receipt if
anything is missing or damaged.
Check that the correct machine has been supplied and that the voltage, marked
on the rating plate, is suitable for the supply available. The rating plate is
located internally on the right hand side of the unit.
INTRODUCTION
The Mistral M60, M90 and M135 are back-bar or under-bar refrigerators
designed for the cooling and storage of beverages.
The following quantity of beverage bottles/mixers can be held in each unit:
Bottle Cooler Capacity
(330ml Bottles / 150ml mixer cans)
TC60 (1850h x 600w x 500d)
272

Page | 4
Mistral Dimensions:
500 mm
1850mm
6
00mm

Page | 5
INSTALLATION
For the Installer
These Instructions contain important information designed to help the user
obtain the maximum benefit from their investment in a Lincat/IMC Mistral Bottle
Cooler.
Please read them carefully before starting work, and consult with the supplier in
the event of any queries.
Be sure to leave this Instruction Manual with the user after installation of the
machine is complete.
Procedure
WARNING
The following table shows the weight and the minimum quantity of
people required to lift each unit:
Bottle Cooler Net Weight Quantity of
People
TC60 (all variants) 87 kg (max) 4
Install the unit on a flat and level floor.
Ensure a minimum 40mm clearance at the back of the unit.
Do not install the unit close to a heat source such as a radiator or a warm air
outlet. Ensure that the unit is standing level by adjusting the feet on the base of
the unit.
The unit has an automatic defrost cycle and evaporates all the condensate
water without the need for a drainage system.

Page | 6
TURNING LED LIGHTS ON-OFF
The cabinet is illuminated by a LED light unit, this light can be turned on or off
by depressing the switch that is located on the plinth next to the digital
controller.
When the switch is flush the lights are on.
Light Switch

Page | 7
REVERSING DIRECTION OF DOOR
On delivery the door of the Mistral TC60 is hinged on the right hand side of the
cabinet. However, it is possible to move the hinge to the other side of the
cabinet by following the steps below.
To change the TC60 door:
Remove the grille cover by moving the cover upwards and then unhooking
the lugs from the bottom of the cabinet.
Hold the door in its closed position to prevent the door from dropping when
the hinge fixings are removed.
Unscrew the hinge fixings.
Remove the hinge and triangular spacer.
Place the door on the ground.
HINGE
FASTENERS
SPACER
GRILLE COVER
Remove the Nylon bush which is located on the underside of the worktop
and push it into the hole on the left hand side.
NYLON BUSH

Page | 8
Unscrew the fixings retaining the door handle and the hinge pin.
Remove the door handle.
Refit the door handle on the right hand side of the door and screw in the
handle fasteners.
Apply one drop of Loctite Studlock 270 to the hinge pin thread.
Refit hinge pin on the left hand side of the door.
Remove the Nylon bush which is located on the underside of the door
and push it into the hole on the left hand side.
HINGE PIN
HANDLE
FASTENERS
NYLON BUSH
Refit the door making sure the hinge pin is inserted into the nylon bush
which is in the worktop.
Refit the hinge and screw in the fasteners making sure the triangular
spacer is clamped between the hinge and the cabinet.
Refit the grille cover as described at the beginning of this section.

Page | 9
ELECTRICITY SUPPLY CONNECTION
Position the unit in the chosen site. The electricity supply connection should be
made to a power outlet socket or isolator mounted on the wall close to the
machine. This socket or isolator must be accessible once the machine is
installed. Before connecting, check that the voltage shown on the rating label is
correct for the electricity supply you have available. If the plug does not fit your
sockets or a longer lead is required, changes must be made by an approved
electrician.
NOTE: The plug is fitted with a 10amp fuse.
The plug fuse cover must be refitted when changing the fuse. In the event of
losing the fuse cover the plug must NOT be used until a replacement fuse cover
has been obtained and fitted or the plug replaced.
WARNING: This machine must be earthed
Should the supply cord become damaged then a replacement must be fitted by
an approved electrician. The IET Codes of Practice must be observed.
The wires in the mains lead are coloured in accordance with the following code:
Green and yellow Earth
Blue Neutral
Brown Live
COMMISSIONING
Before using a bottle cooler for the first time, the interior should be wiped out
with a clean damp cloth.
Allow the machine to stand for 1 hour to allow the refrigerant to settle. Plug in
and switch on at the wall socket. There is no separate switch to turn on the
machine. The compressor will start running less than one minute after the
supply is switched on.
Check that the light is working, and check the switch is operating correctly.
Run the unit empty, and check that cold air is being circulated within the
cabinet.

Page | 10
CHANGING THE CONTROLLER SET POINT
The electronic temperature controller is factory set to 4°C and will cycle the air
temperature between 2°C and 6°C. The set point can be adjusted between 0°C
and 18°C by following the button sequence below:
USING YOUR BOTTLE COOLER
This unit is for cooling bottles and cans only. Do not load the cabinet with boxed
goods as this prevents air circulation and the goods will not cool down as quickly.
While loading ensure that the interior grilles are not obstructed by the bottles.
Do not place hot or warm goods in the cabinet. Only goods at room temperature or
less should be placed in the unit, otherwise performance will be affected. It is
recommended that the cabinet is stocked after closing at night or first thing in the
morning to allow time for the bottles to cool. Ensure that stock is rotated by placing
new stock at the back of shelves or in one side of the cabinet to ensure that colder
bottles are served first.
Do not leave the doors open when the unit is running as this causes the evaporator
to ice up, preventing the unit from operating efficiently.
Ensure that the front grille is always unobstructed.
1)
Use the UP and DOWN buttons, to scroll to the
desired set point temperature (min 0°C, max 10°C).
2)
6
Press SET button to accept.
3)
4
4)
Press SET button and the current set point
temperature will be displayed.
5 Then press stand-by button to esc.
Display will revert back to current
internal air temperature.
4
Press SET the current SET Point will be displayed, if
Loc is displayed then the controller is locked, to
unlock press and hold the SET button for 3 seconds,
UnL will then be displayed.