Button is Pressed:
1. Remove power from the unit by removing jumper
J5 and switch all DIP switches OFF.
2. Switch DIP switches 5 and 8 ON.
3. Restore Power to the Unit by replacing J5.
4. Select the relay to be the new Output Relay.*
no relay is selected, no relay will be activated
the remote button is pressed.)
5. Press the button on a learned remote that
activate the selected relay output.
6. Switch DIP switch 8 OFF.
7. Wait for the LEDís to start flashing alternately.
8. Switch ALL DIP switches OFF.
9. When the LEDís stop flashing the unit is in
normal operating mode.
Protecting Relays from retriggering within 3
minutes after a previous trigger:
1. Remove power from the unit by removing jumper
J5 and switch all DIP switches OFF.
2. Switch DIP switches 5, 7 and 8 ON.
3. Restore Power to the Unit by replacing J5.
4. Select the relay(s) to be retrigger protected.*
5. Switch DIP switch 8 OFF.
6. Wait for the LEDís to start flashing alternately.
7. Switch ALL DIP switches OFF.
8. When the LEDís stop flashing the unit is in
normal operating mode.
Assigning a Relay to be Activated when a RF
Device is Triggered:
1. Remove power from the unit by removing jumper
J5 and switch all DIP switches OFF.
2. Switch DIP switches 5, 6 and 8 ON.
3. Restore Power to the Unit by replacing J5
4. Select the relay to be activated.* (If no relay
selected, no relay will be activated when
remote button is pressed.)
5. Trigger the device that must activate the selected
Relay Output.
7. Wait for the LEDís to start flashing alternately.
8. Switch ALL Dip switches OFF.
9. When the LEDís stop flashing the unit is in
normal operating mode.
Assigning a Dedicated Panic Button to a
N.B. This Function will affect ALL remotes.
1. Remove power from the unit by removing
J5 and switch all Dip switches OFF.
2. Switch Dip switches 4 and 8 ON.
3. Restore Power to the Unit by replacing J5.
4. Press the button on a known remote that
become an instant panic button.
5. Switch Dip switch 8 OFF.
6. Wait for the LEDís to start flashing alternately.
7. Switch ALL Dip switches OFF.
8. When the LEDís stop flashing the unit is in
normal operating mode.
Assigning an Arm / Disarm Button on a Remote:
N.B. This Function will affect ALL remotes.
1. Remove power from the unit by removing
J5 and switch all Dip switches OFF.
2. Switch Dip switches 3 and 8 ON.
3. Restore Power to the Unit by replacing J5.
4. Press the button on a known remote that
become the Arm / Disarm button.
5. Switch Dip switch 8 OFF.
6. Wait for the LEDís to start flashing alternately.
7. Switch ALL Dip switches OFF.
8. When the LEDís stop flashing the unit is in
normal operating mode.
Assigning a Stay Arm Button on a Remote:
N.B. This Function will affect ALL remotes.
1. Remove power from the unit by removing
J5 and switch all Dip switches OFF.
2. Switch Dip switches 2 and 8 ON.
3. Restore Power to the Unit by replacing J5.
become the Stay Arm button.
5. Switch Dip switch 8 OFF.
6. Wait for the LEDís to start flashing alternately.
7. Switch ALL Dip switches OFF.
8. When the LEDís stop flashing the unit is in
normal operating mode.
Assigning the Device Failure Output Relay:
1. Remove power from the unit by removing
J5 and switch all Dip switches OFF.
2. Switch Dip switches 4, 7 and 8 ON.
3. Restore Power to the Unit by replacing J5.
4. Switch Dip switch 4 OFF.
5. Select the relay to be the Device Failure
(If no relay is selected, the device failure relay
be disabled.)
6. Switch Dip switch 8 OFF.
7. Wait for the LEDís to start flashing alternately.
8. Switch ALL Dip switches OFF.
9. When the LEDís stop flashing the unit is in
normal operating mode.
Learning a New RF Device such as a RF Passive
IR:
1. Remove power from the unit by removing
J5 and switch all Dip switches OFF.
2. Switch Dip switches 3, 7 and 8 ON.
3. Restore Power to the Unit by replacing J5.
4. Press the TAMPER switch on the Device to be
Learned.
5. Switch Dip switch 8 OFF.
6. Remove power from the unit and adjust Dip
setting as needed.
7. Restore power to the unit. When the LEDís
flashing the unit will be in normal operating mode.
* * Where indicated DIP switch 1 represents Relay 1,