Read and understand these instructions before installing operating or maintaining this equipment.
The product is designed to be a component of a customized safety oriented control system. It is the responsibility of the user to ensure the correct overall functionality of its systems and machines.
IDEM, its subsidiaries and affiliates, are not in a position to guarantee all of the characteristics of a given system or product not designed by IDEM.
APPLICATION:
Coded Non Contact s itches are designed to interlock hinged, sliding or removable guard doors. They are specifically advantageous hen:
a) poor guard alignment exists
b) high hygiene requirements exist e.g. food industry hose do n
c) a long mechanical life is required (no moving or touching parts).
When used in combination ith a Dual Channel Safety Relay or Control Device, Magnetic Non-Contact S itches can be used to provide protection up to Category 4 and PLe to ISO13849-1.
OPERATION:
All Magnetic Non-Contact Safety S itches are designed to conform to EN60947-5-3 and be used as directed by ISO14119 and EN ISO12100. They have magnetic sensing hich provides a ide
sensing distance and provides a high tolerance to misalignment after sensing. They can operate in extreme environments of temperature and moisture.
IMPORTANT:
The Risk Assessment for the particular application should include the risk of spare actuators. Spare actuators should not be readily available and must be securely controlled.
The safety functions and mechanics must be tested regularly. For applications ere infrequent guard access is foreseeable, the system must have a manual function test to detect a possible
accumulation of faults. At least once per month for PLe Cat3/4 or once per year for PLd Cat3 (ISO13849-1). Where possible it is recommended that the control system of the machine demands and
monitors these tests, and stops or prevents the machine from starting if the test is not done. (See ISO14119).
INSTALLATION:
Installation of all Non Contact S itches must be in accordance ith a risk assessment for the individual application.
Installation of the devices must be carried out by a competent person ith appropriate experience of machine control integration
The use of a Safety Relay or Control Device is recommended for monitoring magnetic s itches. These devices monitor 2 redundant circuits as per ISO13849-1 for up to PLe /Category 4 protection.
M4 mounting bolts must be used to fix the s itches. (Except RPR / RMR types, these types require fitting through 30.5mm clearance holes. The lock nuts supplied must be used to secure the
s itches). Tightening torque for mounting bolts to ensure reliable fixing is 1.0 Nm. Al ays mount on to Non Ferrous materials. The recommended setting gap is 5mm. The Safety s itch must not be
used as a mechanical stop or be adjusted by striking ith a hammer. The actuator must not be allo ed to strike the s itch. Do not mount adjacent s itches or actuators closer than 30mm.
Typical misalignment tolerance after setting is 5mm.
IMPORTANT: The NC switch contacts are potential free and are internally fused. To protect the internal fuse all switches must be externally fused at a lower rating (see Technical data).
After installation al ays check each s itch function by opening and closing each guard individually in turn and ensuring that the LED’s on the Safety Relay or Control Device are illuminated hen the
s itch is closed and are extinguished hen the s itch is open. Check that the machine stops and cannot be re-started hen each s itch is open.
For MPR types, fit the protective scre covers after the final checks have been completed.
MAINTENANCE:
Monthly: Check alignment of actuator and look for signs of mechanical damage to the s itch casing. Check iring for signs of damage.
Check each s itch function by opening and closing each guard individually in turn and ensuring that the appropriate LED’s on the Safety Relay are illuminated hen the s itch is closed and are
extinguished hen the s itch is open. Check that the machine stops and cannot be re-started hen each s itch is open.
Never repair any s itch, actuator or integral cables. Replace any s itch displaying signs of mechanical damage to the casing or cables.
These requirements form part of the product warranty.
RMR (S/STEEL)
WARNING: DO NOT DEFEAT TAMPER OR BYPASS THE SAFETY FUNCTION.
FAILURE TO DO SO CAN RESULT IN DEATH OR SERIOUS INJURY.
AVERTISSMENT: NE PAS DESACTIVER MODIFIER RETIRER OU CONTOURNER
CETI INTERVERROUILLAGE IL PEUT EN RESULTER DES
BLESSURES GRAVES DU PERSONNEL UTILISATEUR.