ICT Protege PRT-KLCD Manuel utilisateur

PRT-KLCD
Protege Alphanumeric LCD Keypad
User Manual

The specifications and descriptions of products and services contained in this document were correct at the time
of printing. Integrated Control Technology Limited reserves the right to change specifications or withdraw
products without notice. No part of this document may be reproduced, photocopied, or transmitted in any form or
by any means (electronic or mechanical), for any purpose, without the express written permission of Integrated
Control Technology Limited. Designed and manufactured by Integrated Control Technology Limited, Protege® and
the Protege® Logo are registered trademarks of Integrated Control Technology Limited. All other brand or product
names are trademarks or registered trademarks of their respective holders.
Copyright © Integrated Control Technology Limited 2003-2022. All rights reserved.
Last Published: 05-Apr-22 5:01 PM
PRT-KLCD | Protege Alphanumeric LCD Keypad | User Manual 2

Contents
Introduction 5
Operation 6
Status Indicators 6
Audible Feedback 7
Keypad Functions 8
Logging in to the Keypad 9
Single Credential Login 9
Dual Credential Login 9
Logging Out 9
Expired PIN 10
Changing Your PIN 11
Arming / Disarming 12
Delay Times 12
Arming an Area 12
Disarming an Area 13
Silencing and Canceling Alarms 14
Bypassing Inputs in an Area 14
Stay Arming an Area 15
Instant Stay Arming an Area 15
Force Arming an Area 16
Instant Force Arming an Area 16
Defer Arming an Area 17
Arming / Disarming Area Groups 18
Trouble Display 19
Alarm Memory 20
Events 21
Additional Features 22
Offline Menu Access 22
Unlocking a Door 23
Panic Alarms 23
Fire Alarms 23
Disabling / Enabling the Audible Output 23
User Management 24
Navigation 24
PRT-KLCD | Protege Alphanumeric LCD Keypad | User Manual 3

Introduction
Protege keypads provide a sleek, user friendly interface to the Protege System, allowing you complete control of
your security and access control system.
Before using your keypad we highly recommend you read this manual carefully and have your security
professional or property manager explain basic system operation to you. For more information visit the ICT
website or ask your system administrator.
PRT-KLCD | Protege Alphanumeric LCD Keypad | User Manual 5

Operation
The following section provides you with the information needed to familiarize yourself with the keypad before
carrying out basic operations.
Status Indicators
The keypad features three status indicator lights showing the condition of the Protege system.
Power Indicator
Disarmed Indicator
Armed / Alarm Indicator
Power Indicator
When the power indicator on, the system is powered and operating normally. If there is a complete power failure
this indicator will be off.
Armed / Alarm Indicator
When the armed/alarm indicator is flashing the system is in alarm and you need to enter your user code to silence
the alarm. When on, the system is armed.
This indicator is programmable and may not function as described here. Verify the operation with your installation
company or security professional.
Disarmed Indicator
When the disarmed indicator is on the system is disarmed. Alternatively, when the disarmed indicator is on the
system may be ready to arm (all inputs are secure). Enter your user code to arm.
This indicator is programmable and may not function as described here. Verify the operation with your installation
company or security professional.
PRT-KLCD | Protege Alphanumeric LCD Keypad | User Manual 6

Confidentiality Mode
Keypads include a confidentiality mode where all lights (Power, Disarm, Arm and LCD backlight) will turn off when
the keypad is not in use. Confidentiality mode may be enabled by your installer.
Audible Feedback
When a key is pressed, a short audible tone is generated. Other tones are generated when certain functions are
performed.
Confirmation Tone
When an operation has been successfully completed, the keypad generates a sequence of four audible tones.
Rejection Tone
When the system times out or when an operation is incorrectly entered, they keypad generates an audible tone for
three seconds.
If required, audible tones can be silenced by pressing and holding the [CLEAR] key for 3 seconds. This option
must be enabled by your security professional or system administrator.
PRT-KLCD | Protege Alphanumeric LCD Keypad | User Manual 7

Keypad Functions
Key Function
0-9 The primary function of the numeric keys is to enter user codes. When controlling devices the [1] key
turns the device on, the [2] turns the device off, and in the on state the [3] key latches the device.
The [ARM] key is used to start the arming process for an area.
The [DISARM] key is used to silence alarms, disarm the area, and cancel an arming sequence.
The [MENU] key is used to access the menu and can be followed by menu shortcut selection key(s)
that represent a menu item.
The [FUNCTION] key can be programmed to unlock a door.
The [STAY] key is used to initiate the stay arming process for an area.
The [FORCE] key is used to force arm an area.
The [MEMORY] key will take a user directly to the memory view menu.
The [BYPASS] key can be pressed when an area is breached during an arming process to bypass the
displayed area.
The [CLEAR] key will log off the user currently logged in to the keypad. When pressed while not
logged in the display will be refreshed.
The [ENTER] key is used to confirm an action on the keypad, acknowledge memory and alarm
information, and move to the next programming screen.
ARROW
KEYS
The arrow keys are used to scroll the menu, move the focus of a program window to the next screen,
and move the cursor when programming or editing values.
PRT-KLCD | Protege Alphanumeric LCD Keypad | User Manual 8

Logging in to the Keypad
When logging in to a keypad, the exact process, messages displayed and menus accessible will depend upon your
site and user configuration. Discuss with your installer which options have been configured for your site.
Single Credential Login
1. To log in, enter your PIN code and press [ENTER].
Once a valid PIN is entered you will be presented with a welcome screen, area status or available menu.
Dual Credential Login
1. To log in using dual credential authentication, enter your User ID credential code and press [ENTER].
2. When prompted, enter your PIN code and press [ENTER].
Once a valid PIN is entered you will be presented with a welcome screen, area status or available menu.
If the Lock Keypad On Excess Attempts option has been enabled on your system, entering an invalid login three
times will lock the keypad for a short period, preventing further login attempts by any user. The lockout time is
defined under the keypad programming.
Logging Out
You are automatically logged out after a short period of inactivity, or if the [CLEAR] key is pressed while you are
logged in.
The period of inactivity is defined by the Time User is Logged In setting under the keypad programming. If no
key presses are detected during this time, you will be logged out automatically and will need to log in again
before you can proceed.
PRT-KLCD | Protege Alphanumeric LCD Keypad | User Manual 9

Expired PIN
For sites that have PIN expiry enabled, the keypad will prompt users to change their PIN:
⦁on the next login after a PINis added or edited in the user interface.
⦁whenever the expiry period is reached.
The user will not be able to log in until their PINis updated.
The new PIN must adhere to the PIN requirements configured in the Site Security Enhancement settings. There
may be limitations on the PIN length, number of repeated digits and/or number of sequential digits.
1. Log in to the keypad. The keypad will advise that your PINhas expired.
PIN has expired!
Please change.
Enter new PIN
code:********
2. Enter your new PIN code, remembering that it must adhere to the PIN requirements configured for your site.
-If your new PIN does not meet the minimum requirements, you will be prompted to try again.
Policy check fail.
Try again.
-If your new PIN meets the requirements, you will be prompted to re-enter your new PIN to confirm.
Re-enter new PIN
code: ********
-If your re-entered new PIN does not match your original entry, you will be prompted to enter it again.
Invalid !
Please re-enter
3. When your valid PIN has been successfully re-entered it will be verified and saved.
Verified
Saving changes.
PRT-KLCD | Protege Alphanumeric LCD Keypad | User Manual 10
Autres manuels pour Protege PRT-KLCD
1
Table des matières
Autres manuels ICT Clavier

ICT
ICT EliteSuite ELT-KLES Manuel utilisateur

ICT
ICT PRT-KLCS Manuel utilisateur

ICT
ICT Protege EliteSuite Manuel utilisateur

ICT
ICT Protege PRT-KLCD Manuel utilisateur

ICT
ICT EliteSuite ELT-KLCS Manuel utilisateur

ICT
ICT PRT-KLCS Manuel utilisateur

ICT
ICT PRT-TS50 Manuel utilisateur

ICT
ICT ELT-KLCS Manuel utilisateur

ICT
ICT EliteSuite Manuel utilisateur

ICT
ICT PRT-TS50 Manuel utilisateur