PEX-P32C32/PISO-P32C32U Series Quick Start Guide ICP DAS CO., LTD.
WebSite: http:// www.icpdas.com.tw E-Mail: service@icpdas.com , service.icpdas@gmail.com
Prepare for device:
DN-37 (optional) wiring terminal board.
Exterior power supply device. For example: DP-665 (optional)
Self-test wiring as follows:
1. Use the DN-37 to connect the CON1 on board.
2. Keep set the J1 and JP2 jumper to External Power (Page 2).
3. Connect the DI(0-15) with DO(0-15). (DI0 with DO0 …DI15 with DO15)
PEX-P32C32 and PISO-P32C32U External Power Wiring:
4. Power Supply (+24 V) connect to ECOM0 (Pin18).
Power Supply (+24 V) connect to Ext.PWR0 (Pin37).
Power Supply GND connect to IGND0 (Pin19).
Power Supply GND connect to Ext.GND0 (Pin1 and Pin20).
PISO-P32C32U-5V External Power Wiring:
4. Power Supply (+5 V) connect to ECOM0 (Pin18).
Power Supply (+5 V) connect to Ext.PWR0 (Pin37).
Power Supply GND connect to IGND0 (Pin19).
Power Supply GND connect to Ext.GND0 (Pin1 and Pin20).
The PEX-P32C32/PISO-P32C32U suggests input voltage range as follow:
Logic high: +9 ~ +24 V; Logic Low: 0 ~ 1V.
(Higher voltage over the limitation will cause the hardware damage.)
The PISO-P32C32U-5V suggests input voltage range as follow:
Logic high: +5 ~ +12 V; Logic Low: 0 ~ 1V.
(Higher voltage over the limitation will cause the hardware damage.)