ICC EXCELPrime Manuel utilisateur

(SW-II_2017-10)
EXCELPrime
18” Clearance Stove Pipe
INSTALLATION AND MAINTENANCE
INSTRUCTIONS
A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN
REQUIRED CLEARANCES (AIR SPACE) TO COMBUSTIBLE MATERIALS. IT IS OF
UTMOST IMPORTANCE THAT THIS CONNECTOR BE INSTALLED ONLY IN
ACCORDANCE WITH THESE INSTRUCTIONS.
Allowable Flue Gas Temperatures
Maximum Continuous
1200°F
650°C
Brief Forced Firing
1700°F
925°C
Tested To
2100°F
1150°C
EXCELPrime is used to connect a solid, liquid and gas fired appliances,
including wood burning stoves, freestanding fireplaces, and furnaces to a pre-
fabricated metal or masonry chimney. EXCELPrime is intended for interior use
only.
Contact local building or fire officials about local restrictions and building
inspections in your area.
Always follow the wood burning stove manufacturer's installation instructions.
Keep these installation and operating instructions in a safe location for future
reference.
EXCELPrime has been tested and listed by
Intertek Testing Services as per Standard ULC-S641
ETL Listing #4005717
ICC INDUSTRIAL CHIMNEY COMPANY INC.
400 J-F KENNEDY,ST.JEROME
QUEBEC,CANADA,J7Y 4B7
Tel.: 450 565-6336 fax: 450 565-6519
www.icc-rsf.com

EXCELPRIME 2 Owner’s Manual
INSTALLATION NOTES
If you are planning to install a wood stove, we recommend that you:
1. Install the stove and stove pipe as described in the Installation Instructions
accompanying the stove. BE CERTAIN TO MAINTAIN THE REQUIRED
CLEARANCES TO COMBUSTIBLE CONSTRUCTION.
2. Keep your flue gases between 300° and 500°F. This will maximize
efficiency while minimizing condensation and creosote formation.
3. Do not burn sea driftwood and treated lumber.
4. Clearance to EXCELPrime can be reduced when combined with listed
EXCELPrime heat shields. Refer to heat shield instructions for details.
5. EXCELPrime is made of coated plain steel. Its durability is limited for coal
installation.
6. Have your chimney cleaned by a qualified chimney sweep. If you want to
clean your chimney yourself, then clean your chimney using a properly fitting
nylon or steel brush. Do not use a brush that will scratch the stainless steel
interior of the chimney. Use of an oversize brush may damage the chimney.
7. Do not expect chemical chimney cleaners to keep your stove pipe clean.
Their use does not negate the necessity of periodically inspecting and
cleaning your chimney.
8. After a chimney fire, do not use the stove again until your chimney and stove
pipe have been inspected by a qualified chimney sweep or Fire Department
Inspector.
9. Do not enclose this stove pipe. It must not pass through floors, attics,
closets, walls or ceilings.
10.EXCELPrime must not exceed 10 feet in length and a maximum of two 90
degrees elbow is permitted.
11. If you plan to connect EXCELPrime to a masonry chimney you should have
the chimney checked by a qualified chimney sweep. Masonry chimneys
should only be used if they are in good condition and meet local building
code.

EXCELPRIME 3 Owner’s Manual
STRAIGHT UP INSTALLATION
For most straight up installations the only
part required is an adjustable length
(SWA). The SWA adjusts to allow any
overall length from 40" to 68". The SWA
is packed in two pieces.
Pick up the section with the expanded top
and slide it into the section with the
shrunk bottom. Do not drop the length or
it may become stuck.
1. Set the adjustable length so that the
shrunk bottom fits into the flue collar of
the stove. Screw the pipe to the flue collar
with three 3/4” metal screws. The black
screws provided are self drilling and will
not normally need a pilot hole for steel
stove collars.
2. Slide the top length of the SWA up over the chimney pipe adapter at the
bottom of the chimney support. Connect it to the adapter with three 3/8’’
metal screws provided.
3. If the system is straight (i.e. no elbows), then it is not recommended to fasten
the slip joint in SWA to allow for expansion.
4. If you require additional height you may add lengths above or below the
adjustable length. Always install the shrunk end on the bottom. Screw two
lengths of EXCELPrime together with the 3/8’’ metal screws provided.
90° ELBOW INSTALLATION
When connecting EXCELPrime to a chimney at the wall, there are multiple
choices for 90° elbows (SW90, SW90C, SW90S & SWA90).
SW90 - 90°elbow
SW90C - Clean Out Elbow
SW90S - Slip Elbow
SWA90 - Adjustable Elbow
SW90
SW90C
SW90S
SWA90
Most 90° elbow installations only require an elbow and the adjustable length
(SWA). If the height from the top of the stove to the top of the elbow is less
than 48”, then you will require a shorter length and a slip section or the slip
elbow. Depending on the wall construction you may also require a short length
between the wall and the elbow to ensure safe clearances.
slip

EXCELPRIME 4 Owner’s Manual
1. Assemble the adjustable
length (see instruction for
straight up installation).
2. Screw the 90° elbow to the
adjustable length using the
3/8” metal screws
provided.
3. Set the adjustable length
so that the shrunk bottom
fits into the flue collar of the
stove. Screw the pipe to
the flue collar with three
3/4” metal screws. The
black screws provided are
self drilling and will not
normally need a pilot hole
for steel stove collars.
4. Extend the adjustable length up until the 90° elbow reaches the chimney
pipe adapter. Screw the elbow to the adapter using the three 3/8” metal
screws provided.
5. Screw the two sections of the adjustable length together using at least one
3/8” metal screw provided.
MASONRY CHIMNEYS
Connecting to an existing masonry chimney with EXCELPrime requires a
masonry adapter (SWM).
To block off a vacant opening into a masonry chimney you can use the masonry
plug (SWMP). Follow step 1 below for installation.
1. Install the Masonry Adapter (SWM). Bend the tabs
outwards and press the Masonry Adapter firmly
into the existing thimble of the masonry chimney.
The tabs will secure it in place.
2. Insert a length of EXCELPrime into the opening of
the masonry adapter. The length should pass all
the way through the adapter and extend into the
flue of the masonry chimney. Secure the length in
place by screwing into the tabs on the masonry
adapter.

EXCELPRIME 5 Owner’s Manual
DAMPER INSTALLATION (UBD)
The damper (SWD) allows you to control the air drawn through the chimney
and controls your stove's
combustion.
When the handle is in the vertical
position, the damper is fully open,
allowing the maximum volume of
combustion gases to flow.
Rotating the handle restricts
combustion gas flow and slows the
combustion process in the stove.
Minimum setting is 20% open.
Rules to follow
•The damper must be installed in a
vertical run of EXCELPrime and never
on a horizontal run.
Installation
The SWD damper is installed like a normal
length of ULTRABlack.
1. Install a fixed section of EXCELPrime
onto the flue collar of the appliance and
secure using three 1/2" metal screws.
2. Install the SWD damper on this section
with the seam to the back, ensuring that
the handle is located to the right of the
chimney. Secure to the lower connector
using the three screws provided.
3. Complete the installation by following the instructions for either a vertical
chimney or a chimney with elbows.
Note: Plan the fixed and adjustable measurements that you will require in
advance. Adjustable or slip sections should always be installed above a SWD.
A slip section cannot be installed directly onto the SWD.
Barometric Damper Adapter
If adding a barometric damper to your system, the
Barometric Damper Adapter (SWBA) permits a
tee to connect to a barometric damper. Connect
the SWBA to the snout of the tee with the screws
provided and then connect barometric damper to
the opposite end of the SWBA.
100% open
20% open

EXCELPRIME 6 Owner’s Manual
5 YEAR WARRANTY
EXCELPrime Chimney Connector
ICC warrants its EXCELPrime chimney connector lengths to be free from
functional failure due to defects in material or workmanship for a period of
five years. This warranty provides for replacement of any connector lengths
which fail as a result of normal use on a residential freestanding fireplace,
wood burning stove, furnace or boiler. This warranty does not cover
damage caused to the building by chimney fires or misuse of the product.
ICC will only be responsible for repair or replacement of any connector
lengths found to be defective under this warranty. In no event shall ICC be
responsible for any incidental or consequential damage caused by defects
in the EXCELPrime chimney connector.
To obtain service under this warranty the defective connector should be
returned to the dealer from whom it was purchased. If you are unable to
return the connector to the original dealer contact ICC for the name of the
closest dealer who can assist you. ICC will not be responsible for shipping
charges related to warranty replacements. ICC will repair or replace any
lengths which, upon examination by an authorized agent of ICC, prove to
be defective.
ICC will not be responsible for labour of any kind required in the removal or
replacement of an EXCELPrime part replaced under this warranty.
This connector is designed to vent residential heating oil, untreated wood,
low sulphur coal, and natural or LP gas. It is designed to operate at a
continuous temperature of 1200°F or less. This warranty is void if the
connector is used in an application for which it is not designed.
The EXCELPrime system must be installed according to the Installation
Instructions included with every system at the time of purchase, if you do
not have a set of installation instructions they are available free upon
request. This warranty is void if the connector is not installed according to
the installation instructions.
This warranty may not be extended or modified by our agents or
representatives. This warranty is in lieu of all other express warranties or
guarantees, of any kind.

EXCELPRIME 7 Owner’s Manual

EXCELPRIME 8 Owner’s Manual
Table des matières
Autres manuels ICC Accessoires de cheminée
Manuels Accessoires de cheminée populaires d'autres marques

Bronpi
Bronpi KIT-1 Manuel utilisateur

Town & Country Fireplaces
Town & Country Fireplaces 22150051 Manuel utilisateur

Travis Industries
Travis Industries 33 DVI Manuel utilisateur

Superior
Superior ASD3628-TI Manuel utilisateur

pleasant hearth
pleasant hearth OFP28WG Manuel utilisateur

IHP
IHP Astria Series Manuel utilisateur

Firegear
Firegear FG-H-2110SS Manuel utilisateur

Nibe
Nibe Contura C i31 Manuel utilisateur

kozy heat
kozy heat KZK-052 Manuel utilisateur

SimpliFire
SimpliFire SF-WM36 Manuel utilisateur

Bluegrass Living
Bluegrass Living BC18NR Guide de démarrage rapide

pleasant hearth
pleasant hearth IRIS SCROLL Manuel utilisateur