IBA ibaPQU-S Manuel utilisateur

Manual
Issue 1.0
1
ibaPQU-S
Power Quality Measurement Unit according to
IEC61000-4-30 Ed. 3 Class A
Manual
Issue 1.5

Manual
ibaPQU-S
Manufacturer
iba AG
Königswarterstr. 44
90762 Fürth
Germany
Contacts
Head office +49 911 97282-0
Fax +49 911 97282-33
Support +49 911 97282-14
Technology +49 911 97282-13
E-mail: iba@iba-ag.com
Web: www.iba-ag.com
This manual must not be circulated or copied, or its contents utilized and disseminated, without
our express written permission. Any breach or infringement of this provision will result in liability
for damages.
© iba AG 2023, all rights reserved.
The content of this publication has been checked for compliance with the described hardware and
software. Nevertheless, deviations cannot be excluded completely so that the full compliance is
not guaranteed. However, the information in this publication is updated regularly. Required cor-
rections are contained in the following regulations or can be downloaded on the Internet.
The current version is available for download on our web site www.iba-ag.com.
Copyright notice
Windows®is a label and registered trademark of the Microsoft Corporation. Other product and
company names mentioned in this manual can be labels or registered trademarks of the corre-
sponding owners.
Certification
The product is certified according to the European standards and directives. This product meets
the general safety and health requirements.
Further international customary standards and directives have been observed.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pur-
suant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harm-
ful interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequencyenergy and, if notinstalled and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in residential
area is likely to cause harmful interference in which case the user will be required to correct the interference
at his own expense.
Issue
Date
Revisions
Chapter
Author
Version HW/FW
1.5
04-2023
Accessories, GUI, FO cable

Manual
Issue 1.5
3
Table of Contents
1About this manual...........................................................................................7
1.1 Target group..................................................................................................8
1.2 Notations....................................................................................................... 8
1.3 Used symbols................................................................................................9
2Introduction ...................................................................................................10
2.1 Modular concept...........................................................................................11
2.2 Measurements according to EN50160.........................................................12
3Scope of delivery...........................................................................................12
4Safety instructions........................................................................................13
4.1 Intended use ............................................................................................... 13
4.2 Special safety instructions........................................................................... 13
5System requirements....................................................................................14
5.1 Hardware ....................................................................................................14
5.2 Software...................................................................................................... 14
5.3 Firmware..................................................................................................... 14
6Mounting, connecting, dismounting............................................................15
6.1 Mounting..................................................................................................... 15
6.2 Connecting..................................................................................................16
6.3 Dismounting................................................................................................16
7Device description ........................................................................................17
7.1 Views ..........................................................................................................17
7.2 Display elements.........................................................................................18
7.2.1 Operating state L1…L4 ............................................................................... 18
7.2.2 LEDs L5…L8...............................................................................................18
7.2.3 Indicators digital inputs L10…L17................................................................ 19
7.3 Operating elements..................................................................................... 19
7.3.1 ON/OFF switch S11..................................................................................... 19
7.3.2 Rotary switches S1 and S2 ......................................................................... 19
7.4 Communication interfaces........................................................................... 20
7.4.1 Fiber optic connections X10 and X11 ..........................................................20
7.4.2 Network interface X22................................................................................. 20
7.5 Digital inputs X5.......................................................................................... 20
7.5.1 Connection diagram / pin assignment..........................................................20
7.5.2 Debounce filter............................................................................................21
7.6 Voltage supply............................................................................................. 24
7.6.1 Voltage supply X14......................................................................................24
7.6.2 Buffer voltage X30....................................................................................... 24
8Measurement principles and measured quantities....................................25
8.1 Grid types.................................................................................................... 25
8.2 Signals and calculated characteristic values ...............................................26
8.3 System integration.......................................................................................28

Manual
ibaPQU-S
4
Issue 1.5
8.4 Time synchronization .................................................................................. 28
8.5 Signal processing........................................................................................ 28
8.5.1 Sampling rate.............................................................................................. 28
8.5.2 Signal filtering ............................................................................................. 29
8.5.3 Automatic range switching .......................................................................... 29
9Updates..........................................................................................................31
9.1 Update via ibaPDA...................................................................................... 31
9.2 Update of the modules................................................................................ 31
10 Configuration with ibaPDA...........................................................................33
10.1 First steps ................................................................................................... 33
10.1.1 Overview of the modules in ibaPDA............................................................ 40
10.2 Basic modules in I/O Manager .................................................................... 41
10.2.1 PQU-S –“General” tab................................................................................ 41
10.2.2 PQU-S –“Analog” tab ................................................................................. 43
10.2.3 PQU-S –“Digital” tab .................................................................................. 43
10.2.4 PQU-S –“Diagnostics” tab.......................................................................... 44
10.2.5 ibaPQU-S –“General” tab........................................................................... 45
10.2.6 ibaPQU-S –“Digital” tab.............................................................................. 46
10.2.7 ibaPQU-S –“Status” tab.............................................................................. 47
10.2.8 Diagnostics - “General” tab ......................................................................... 48
10.2.9 Diagnostics - “Digital” tab ............................................................................ 48
10.3 Submodules to calculate characteristic values............................................ 50
10.3.1 Grid module ................................................................................................ 50
10.3.2 EN50160 submodule: Power frequency...................................................... 54
10.3.3 Submodule EN50160: Supply voltage variation........................................... 56
10.3.4 EN50160 submodule: Flicker severity......................................................... 57
10.3.5 EN50160 submodule: Supply voltage unbalance........................................ 58
10.3.6 EN50160 submodule: Harmonic voltage ..................................................... 59
10.3.7 EN50160 submodule: Mains signalling voltage........................................... 61
10.3.8 EN50160 submodule: Voltage events.......................................................... 63
10.3.9 Basic submodule......................................................................................... 64
10.3.10 Phasor submodule...................................................................................... 66
10.3.11 Power submodule ....................................................................................... 68
10.3.12 Spectrum submodule.................................................................................. 70
10.3.13 Unbalance submodule ................................................................................ 73
10.3.14 Flicker severity submodule.......................................................................... 75
10.3.15 Aggregation submodule .............................................................................. 77
10.3.16 Commutation notches submodule............................................................... 82
10.3.17 Events submodule....................................................................................... 83
11 Technical data ...............................................................................................85
11.1 Main data.................................................................................................... 85
11.2 Interfaces.................................................................................................... 86
11.3 Digital inputs ............................................................................................... 87
11.4 Grid characteristics ..................................................................................... 88

Manual
Issue 1.5
5
11.5 Dimensions ................................................................................................. 89
11.6 Connection diagram.................................................................................... 93
11.6.1 Pin assignment voltage supply X14.............................................................93
11.6.2 Pin assignment digital inputs X5..................................................................93
11.7 Example for FO budget calculation.............................................................. 94
12 Accessories...................................................................................................96
12.1 Backplane panels........................................................................................96
12.1.1 ibaPADU-S-B4S.......................................................................................... 96
12.1.2 ibaPADU-S-B1S.......................................................................................... 99
12.2 Mounting system for central unit................................................................ 101
12.2.1 ibaPADU-S-B ............................................................................................ 101
12.3 Mounting systems for ibaPADU-S-B4S...................................................... 103
12.3.1 Mounting angles........................................................................................ 103
12.3.2 Mounting panel 19“.................................................................................... 104
12.3.3 Module carrier........................................................................................... 109
12.4 Terminal blocks ..........................................................................................110
12.5 I/O modules iba modular system................................................................111
12.6 FO cards/cables.........................................................................................112
12.7 iba software................................................................................................112
13 Appendix......................................................................................................113
13.1 Calculating characteristic values ................................................................113
13.1.1 RMS (Root Mean Square)..........................................................................113
13.1.2 Rectified value............................................................................................113
13.1.3 Peak value .................................................................................................113
13.1.4 Form factor.................................................................................................113
13.1.5 Crest factor ................................................................................................113
13.1.6 Frequency..................................................................................................113
13.1.7 Harmonics, interharmonics, phase angle....................................................113
13.1.8 THD (Total Harmonic Distorsion)................................................................113
13.1.9 Flicker ........................................................................................................114
13.1.10 Power / Energy...........................................................................................114
13.1.11 Voltage balance / Unbalance......................................................................117
13.1.12 Interference factor......................................................................................118
13.1.13 Commutation notches ................................................................................119
13.1.14 Events....................................................................................................... 120
13.2 Connection examples................................................................................ 122
13.2.1 1-phase..................................................................................................... 122
13.2.2 Star connection......................................................................................... 122
13.2.3 Delta connection ....................................................................................... 123
13.2.4 Connection with instrument transformers .................................................. 123

Manual
ibaPQU-S
6
Issue 1.5
14 Index ............................................................................................................125
15 Certificate ....................................................................................................126
16 Support and contact...................................................................................127

Manual
Issue 1.5
7
1 About this manual
This manual describes the design, use and operation of the ibaPQU-S. For information
on the design, use and operation of the I/O modules, please refer to the dedicated man-
uals.
Note
The documentation for the iba-modular system is part of the data medium “iba Soft-
ware & Manuals”. The documentation is also available at www.iba-ag.com in the
download area.
The documentation of the ibaPQU-S system comprises the following manuals:
ibaPQU-S central unit
The manual contains the following information:
Scope of delivery
System requirements
Device description
Installation/Removal
Start-up
Configuration
Technical data
Accessories
Modules
The manuals of the single modules contain specific information about the module.
For example:
Brief description
Scope of delivery
Product characteristics
Configuration
Description of the functions
Technical data
Connection diagram

Manual
ibaPQU-S
8
Issue 1.5
1.1 Target group
This manual addresses in particular thequalified professionals whoare familiar with han-
dling electrical andelectronic modules aswell as communication and measurement tech-
nology. A person is regarded to as professional if he/she is capable of assessing safety
and recognizing possible consequences and risks on the basis of his/her specialist train-
ing, knowledge and experience and knowledge of the standard regulations.
1.2 Notations
The following designations are used in this manual:
Action
Notations
Menu command
Menu „Logic diagram“
Call of menu command
„Step 1 – Step 2 –Step 3 –Step x”
Example:
Select menu „Logic diagram – Add –New logic
diagram”.
Keys
<Key name>
Example:
Example: <Alt>; <F1>
Press keys simultaneously
<Key name> + <Key name>
Example:
<Alt> + <Ctrl>
Buttons
<Key name>
Example:
<OK>; <Cancel>
File names, Paths
„File name“
„Test.doc“

Manual
Issue 1.5
9
1.3 Used symbols
If safety instructions or other notes are used in this manual, they mean:
The non-observance of this safety information may result in an imminent risk of death
or severe injury:
By an electric shock!
Due to the improper handling of software products which are coupled to input and
output procedures with control function!
If you do not observe the safety instructions regarding the process and the system or
machine to be controlled, there is a risk of death or severe injury!
The non-observance of this safety information may result in a potential risk of death
or severe injury!
The non-observance of this safety information may result in a potential risk of injury or
material damage!
Note
A note specifies special requirements or actions to be observed.
Tip
Tip or example as a helpful note or insider tip to make the work a little bit easier.
Other documentation
Reference to additional documentation or further reading.

Manual
ibaPQU-S
10
Issue 1.5
2 Introduction
ibaPQU-S is a modular system to measure power qualitypower parameters using
ibaPQU-S as central unit.
ibaPQU-S measures raw values such as current and voltage in sync with the grid and
calculates the characteristic values according to IEC 61000-4-30 Ed. 3 Class A. Charac-
teristic values include:
Frequency
RMS and maximum value, rectified value, form factor, crest factor
FFT (harmonics, interharmonics up to 50th order)
THD (Total Harmonic Distortion)
Phase values (U/I phase angle to the reference voltage)
Power values (active power, apparent power, reactive power, cos θ, electric energy,
power factor for individual lines and for the total grid)
Symmetrical components (positive, negative and zero sequence component) and
supply voltage unbalance
Flicker (according to IEC 61000-4-15, short-term, long-term)
Event detection (voltage dip, voltage swell, voltage interruption, rapid voltage
changes, ripple control signal)
In addition, ibaPQU-S calculated the following values:
Commutation notches
Flicker for currents
Symmetrical components (positive, negative and zero sequence component) and
current unbalance
ibaPQU-S is suitable for the following grids:
DC
50 Hz
60 Hz
Modular concept
Table des matières
Autres manuels IBA Matériel réseau
Manuels Matériel réseau populaires d'autres marques

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL Manuel utilisateur

B&B Electronics
B&B Electronics ZXT9-IO-222R2 Manuel utilisateur

Yudor
Yudor YDS-16 Manuel utilisateur

D-Link
D-Link ShareCenter DNS-320L Manuel utilisateur

Samsung
Samsung ES1642dc Instructions d'utilisation

Honeywell Home
Honeywell Home LTEM-PV Instructions de montage