These tting and User Instructions refer to the following models:
AP25LM AP50LM AP75LM AP100LM
The HYCO Apollo series is a range of white enamelled cistern fed rectangular water storage
heaters. All HYCO Apollo units can be connected directly to the cold water main and if required,
can supply more than one outlet without the need for special taps.
WARNING!
-The appliance is not to be used by children or persons with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction.
-Children should be supervised and not allowed to play with the appliance.
-Maximum water pressure 690kPa
THESE INSTRUCTIONS SHOULD BE CAREFULLY READ AND UNDERSTOOD BEFORE
INSTALLATION BEGINS. IT WOULD BE DANGEROUS TO PROCEED IF ANY PART IS
UNCLEAR OR IF THE REQUIREMENTS CANNOT BE FULLY MET.
PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER AFTER INSTALLATION.
INSTALLATION
WALL MOUNTING (refer to diagram A).
The unit is designed to be wall mounted and must be tted at least one metre above the
highest draw-off point thus ensuring a good ow. It is important that sufcient clearance is
allowed to ensure access to the ball valve assembly.
The wall xing points will accept 8mm bolts which should not be less than 50mm in length.
ALWAYS ENSURE THAT THE WALL IS SUFFICIENTLY STRONG TO CARRY THE WEIGHT
OF THE UNIT WHEN IT IS FULL OF WATER.
PIPEWORK CONNECTIONS (refer to Diagram B).
The installation must conform to all local authority byelaws. The cold water supply and warning
pipe (overow) assembly can be connected to either side of the unit. The respective apertures
are pre-formed in the outer case and these should be used as guides for cutting through the
cold water tank. A 22mm hole is required for the inlet and a 27mm hole for the warning pipe.
An isolating valve must be tted to the cold water mains supply to allow for servicing.
FITTING TO THE COLD WATER TANK (refer to Diagram C).
The HYCO Apollo series of water heaters are supplied with all the components that are required
to comply with the WRC bylaw 30. The arrangement of these should conform to Diagram C.
The lter and breather assembly is a push snap-t connection and should be tted to the lid in
the aperture provided.
The warning pipe assembly (overow) has three components. The threaded elbow (tank
connector) is inserted through the hole that has been cut, and tightened with the nut and
sealing washer on the inside of the tank.
The 90o bend internal “dip tube” is pushed rmly into the connector facing downwards. The
warning pipe (overow) screen is located securley into the downwards external connection of
the connector.
The ball valve assembly is tted as required, adjusting the oat to ensure that the water level
in the tank does not exceed the water level line.
NOTE: after installation, replace lid and secure with the retaining screw supplied.