H1 Self Contained glass front multideck Installation manual
________________________________________________________________________________________________________________________
Hussmann Page 8
•Wipe case with a clean, damp cloth, if necessary
Starting up
•Check supply power is ready and correct voltage. (by Licensed Person)
Turn case power on
Start up checks –by qualified persons only
Check that all fans and lights are working correctly.
Check and set if necessary expansion valves as per Product Engineering Data –Available from Hussmann.
Approximately 24 hours after start-up, check that the case is at correct operating temperature (refer the Product
Engineering Data).
Decommissioning
Plan and risk assess the decommissioning process to include the following:
Isolate the case.
Removal of the case is to be in the reverse order of installation listed previously.
Disposal
Case disposal is to be carried out by the following:
Metal component removed and recycled
Remaining by commercial waste management
Maintenance
General
•Do not use abrasive, solvent, ammonia or oil based cleaners,
•Do not use steam or high pressure systems to clean the case as they may reduce the life and alter the
performance of the case
•The case does not have a floor drain. Do not bucket more than 2 litres into the case during cleaning.
•Avoid contact between cleaning products and electrical components. Keep electrical connections dry at all times.
•Wear protective gloves to prevent scratches or cuts
•Wear safety glasses when there is a risk of splashing from water and cleaning solutions