Hundure RAC-510PE Manuel utilisateur

RAC-510/511PE
Standalone Access Controller
Hardware Manual
Version 1.0

Table of Contents
Chapter 1 Product Overview................................................................................................4
1.1 Package Contents ..................................................................................................4
1.2 Features .................................................................................................................5
1.3 Specifications .........................................................................................................6
Chapter 2 Physical Dimension.............................................................................................7
2.1 Dimension...............................................................................................................7
2.2 Appearance Introduction.........................................................................................8
Chapter 3 System Configuration & Wire Connections .......................................................10
3.1 System Configuration ...........................................................................................10
3.2 Wire Connections .................................................................................................12
3.2.1 Communication Interface Connection.........................................................12
3.2.2 ACU-30 Wire Diagram ................................................................................13
3.2.3 Alarm Connection .......................................................................................14
3.2.4 Electronic Lock Setup.................................................................................15
3.2.5 Exit Button/Door Sensor Connection ..........................................................16
3.2.6 Slave Reader Connection...........................................................................18
3.2.7 Power Supply Connection ..........................................................................19
Chapter 4 Installations .......................................................................................................20
4.1 Hardware Setup....................................................................................................20
Chapter 5 Setting...............................................................................................................21
5.1 ID Setting..............................................................................................................21
5.2 Function Settings ..................................................................................................22
5.2.1 Add a Card Number....................................................................................23
5.2.2 Delete a Card Number................................................................................24
5.2.3 Delete All Card Numbers ............................................................................25
5.2.4 Successive Addition of Card Numbers .......................................................26
5.2.5 Successive Deletion of Card Numbers .......................................................27
5.2.6 Set Door Relay Mode .................................................................................28
5.2.7 Set Unlock Door Time.................................................................................29
5.2.8 Door Sensor Detection Time ......................................................................30
5.2.9 Enable/Disable Conditional Unlock Door Settings ......................................31
5.2.10 Compare valid Address ............................................................................32
5.2.11 Advanced Settings 1.................................................................................33
HUNDURE 2RAC-510/511PE Hardware manual
5.2.12 Advanced Settings 2.................................................................................34

5.2.13 Re-swipe Card Check Time......................................................................35
5.2.14 Sensor NO/NC Settings............................................................................36
5.2.15 Access Granted for Master Code ............................................................37
5.2.16 Set Date....................................................................................................38
5.2.17 Set Time ...................................................................................................39
5.2.18 Enable/Disable Keypad ............................................................................40
5.2.19 Save Invalid Card No................................................................................41
5.2.20 Set Master Code.......................................................................................42
5.2.21 Set Disarm Card/Code..............................................................................43
5.2.22 Set Duress Card(Code) ............................................................................44
5.2.23 Set Memory Mode ....................................................................................45
5.2.24 Door Open Mode ......................................................................................46
5.2.25 Slave Reader Setting................................................................................47
5.2.26 System Initialization..................................................................................48
Chapter 6 Testing ..............................................................................................................49
Chapter 7 Troubleshoot .....................................................................................................50
Appendix............................................................................................................................51
Appendix A:RAC-510/511 Function List...................................................................51
Appendix B:Wiring Material Requirements...............................................................54
Revision History
HUNDURE 3RAC-510/511PE Hardware manual
Version Description
V1.0 First Edition

Chapter 1 Product Overview
1.1 Package Contents
Controller x 1
Base x 1
Quick Start Guide x 1 Screw x 3
Cable x 1
HUNDURE 4RAC-510/511PE Hardware manual

1.2 Features
zSupports standalone operation
zMemory capacity 1,024 cardholders / 800 events.
zProvides RS-485 communication interface for management through PC.(RAC-510PE)
zProvides unlock door modes by card or card + PIN; programmable unlock door
duration.
zCasing tamper proof detection and door ajar alarm. Programmable door sensor
detection time
zDuress card/code setting. When door opened in the emergency, controller will send a
signal to control center at the same time for tracing and rescue.
zWatchdog function secures system free from halting.
zWorking with slave reader to have Anti-Pass back function
HUNDURE 5RAC-510/511PE Hardware manual

1.3 Specifications
Model No. RAC-510PE RAC-511PE
Read Format EM (125 KHz )
Read Range 6~8cm
Slave Reader T2/Wiegand
Input Ports 3 Sensors(Door SensorX1, Exit ButtonX1, Case SensorX1)
Output Ports(Built-in ) Relay X 1(Door Lock)
Output Ports(External) O.C Output X2 (Door Lock/Alarm, external ACU-30)
Cardholders/Events 1024/800
LED Indicator Comm.
Keypad 12 Keys ( 0-9, *,# )
Real Time Clock YES None
Beep Tone Buzzer
Communication Interface RS-485 None
Communication Baud Rate 19200 bps-N-8-1 None
ID Setting DIP switch setting None
Operating Voltage DC 12V /1A
Power Consumption 250mA (Max)
Operating Temperature -40℃~ 70℃/-40℉~158℉
Relative Humidity 20% ~ 80% (Non-condensing)
Dimensions 120mm(L)X77mm(W)X21mm(H)
Weight 120g
HUNDURE 6RAC-510/511PE Hardware manual
* Product design and specifications are subject to change without prior notice.

Chapter 2 Physical Dimension
2.1 Dimension
Scale: mm
HUNDURE 7RAC-510/511PE Hardware manual

2.2 Appearance Introduction
HUNDURE 8RAC-510/511PE Hardware manual
A Case Sensor
B ID Settings
C Kindly refer to the pin assignments below3.2.2
D
Built-in Relay
When Electric Bolt Lock is used, kindly connect the wire to COM

and NC contacts.
When Electric Strikes Lock is used, kindly connect the wire to
COM and NO contacts.
HUNDURE 9RAC-510/511PE Hardware manual

Chapter 3 System Configuration & Wire Connections
3.1 System Configuration
RAC-510
HUNDURE 10 RAC-510/511PE Hardware manual
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Hundure Contrôleurs d'accès IP