Hultafors DPL Manuel utilisateur

DPL
Operating instructions
EN

2
INCLUDED IN DELIVERY WITH THE DPL
DPL
Belt pouch
AA battery

3
Operating manual
Digital Spirit Level DPL
About this manual
Congratulations on the purchase of your new DPL!
You have acquired a Hultafors measuring
instrument, which can make your work easier,
faster and more precise. To utilize the complete
functionality range of this measuring instrument,
and to ensure safe operation, please observe the
following instructions:
• Please read this operating manual before
starting to use the device.
• Always keep the operating manual near
the device.
• Only hand over the device to other users
together with the operating manual.
• Never render the attached warning signs
unreadable.
Contents
1. General information
2. Description
3. Technical data
4. Safety instructions
5. Getting started
6. Operation
7. Calibration
8. Maintenance, storage and transportation
9. Scope of delivery and accessories
10. Troubleshooting
11. Disposal
12. Warranty
13. EC conformity declaration

4
1.1 Signal words and their meaning
DANGER
For an imminent danger that could lead to
serious injury or death.
WARNING
For a possibly dangerous situation that could
lead to serious injury or death.
CAUTION
For a possibly dangerous situation that could
lead to slight injury or property damage.
NOTE
For application notes and other useful information.
1. General information
1.2 Pictograms and other information
1.2.1 WARNING SIGNS
Warning of dangers in general.
1.2.2 SYMBOLS
Read instructions before use.
Batteries and devices must not be
disposed of with household waste.
Do not throw batteries into a fire.
Warning signs on battery: Do not
heat the battery above 60 °C.

1. 4.
5.
2.
3.
5
1. On/O switch
2. Hold function (measurement is retained by pressing once) /
Toggling between ABS (absolute) and INC (incremental)
3. Mode button for switching between measured value settings (°, mm/m, %, in/)
4. Calibration
5. Changing the display resolution
2. Description

6
3. Technical data
Gradient module
Max. measurement tolerance
0° & 90° ± 0.05°
1°–89° ± 0.20°
Protection class IP 52
Power supply 1 x AA battery
Battery life (at 20°C) 65 h (if display light switched o, approx. 80h)
Permissible temperatures
Operating temperature -10°C to +50°C
Storage temperature -20 °C to +60 °C

7
4. Safety instructions
4.1 Area of responsibility
4.1.1 MANUFACTURER
Hultafors is responsible for the safe delivery
condition of the product, including the operating
manual and the original accessories.
Hultafors Group AB
Hultaforsvägen 21
517 21 Bollebygd, Sweden
4.1.2 OPERATOR
e operator is responsible for using the product
as intended, the deployment of personnel,
their training and the operational safety of the
product.
• e operator understands the safety
information which is stated on the product
and the instructions which are contained in
the operating manual.
• e operator shall comply with local
regulations relating to safety and accident
prevention regulations as well as worker
protection laws and regulations.
• e operator shall immediately notify Hultafors
if safety-related issues should develop on the
product or during its utilization.
• e operator shall ensure that the product
is not utilized any further if defects become
evident, and he will have the product repaired
professionally.
4.2 Improper Use
• Use of the device and the accessories without
instruction.
• Use of third-party accessories or additional
equipment.
• Use outside of the intended limits
(see Chapter 3 Technical data).
• Use under extreme temperature fluctuations
without an adequate acclimatization.
• Disabling of safety devices and removal of
hazard notices and labels.
• Unauthorized opening of the device.
• Performance of modifications or alterations
the device or the accessories.
• Deliberate blinding of third parties.
• Inadequate safeguarding at the installation site.
4.3 Utilization limitations
e DPL is suitable for a continuous use in an
atmosphere which can be inhabited by humans.
• Do not operate the product in explosion-prone
or corrosive environments.
• Inform the local safety authorities and
safety experts before working in hazardous
environments, in close proximity to electrical
installations or similar surroundings.

8
4.4 Usage Hazards
4.4.1 GENERAL
WARNING
Missing or incomplete instructions may
result in improper or incorrect use.
is can cause accidents with serious
damages to persons, property, assets
and the environment.
• Follow the manufacturer‘s and operator‘s
safety instructions.
• Protect equipment and accessories from
access by children.
CAUTION
A fall, longer storage, transportation
or other mechanical eects can lead
to erroneous measurement results.
Check the unit for damage before use.
Do not use damaged equipment.
• Repairs have to be exclusively performed by
Hultafors.
• Before use, check the accuracy of the device
(see Chapter 7 Calibration).
4.4.2 CHARGER/BATTERIES/RECHARGEABLE
BATTERIES
DANGER
Strong mechanical influences, can
lead to a leakage, fire or explosion of
the batteries or trigger the release
of toxic substances.
• Batteries and rechargeable batteries may not
be opened or exposed to mechanical loads.
• Damaged batteries may not be used.
• Repairs have to be exclusively performed by
Hultafors.
WARNING
High ambient temperatures and
immersion into liquids can cause
a leakage, fire or explosion of the
batteries or trigger the release of
toxic substances.
• Protect batteries and rechargeable batteries
from mechanical influences during transport.
• Do not overheat batteries and rechargeable
batteries or expose them to fire.
• Avoid the ingress of moisture into batteries
and rechargeable batteries.
• Do not use damaged batteries or rechargeable
batteries. Perform a proper disposal
(see Chapter 11 Disposal).

9
WARNING
A short-circuiting or unintended use can
cause batteries to overheat and create
an injury or fire hazard.
• Do not transport or store batteries in the
pockets of garments.
• Do not bring the battery contacts in contact
with jewelery, keys, or other electrically
conductive objects.
• Do not charge non-rechargeable batteries.
• Do not discharge the batteries through
short-circuiting.
• Do not solder the batteries within the device.
• Do not mix old and new batteries, and do not
mix batteries from dierent manufacturers or
with a diering type designation.
WARNING
If disposed of improperly third parties
can possibly be seriously injured and
the environment polluted. e burning
of plastic components generates toxic
fumes which may impair the health
of people. Batteries/rechargeable
batteries may explode if they are
damaged or heated excessively, and
thereby cause poisoning, burning,
corrosion or environmental
contamination.
If disposed of negligently unauthorized
persons are able to use the product
improperly.
• e product must not be disposed of together
with household waste. Dispose of the device
and accessories properly
(see Chapter 11 Disposal).
• Protect the product at all times from access
through unauthorized persons, especially
children.
4.5 Electromagnetic compatibility (EMC)
e electromagnetic compatibility is the ability of
the product to function in an environment where
electromagnetic radiation and electrostatic
discharges are present, without causing
electromagnetic interference to other devices.

10
4.6 FCC statement
WARNING
e user is cautioned that changes or
modifications not expressly approved
by the party responsible for compliance
could void the user‘s authority to
operate the equipment.
is device complies with Part 15 of the
FCC Rules. e following two conditions apply for
operation: (1) this device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
NOTE
is device has passed the compliance
test for limits for a digital class B
device as per Part 15 of the FCC Rules.
ese limits are designed to provide
reasonable protection against harmful
interference in a residential installation.
4.5.1 INTERFERENCE OF OTHER DEVICES
BY DPL
Although the product meets the strict
requirements of the relevant directives and
standards, Hultafors can not completely
exclude the possibility of interference with other
devices (for example, when using the product in
combination with third-party devices, such as
field computers, personal computers, wireless
devices, mobile phones, certain cables or
external batteries).
• When using computers and radio equipment
make sure to observe the vendor-specific
information about electromagnetic
compatibility.
• Only use original Hultafors equipment and
accessories.
4.5.2 INTERFERENCE OF THE DPL
BY OTHER DEVICES
Although the product meets the strict
requirements of the relevant directives and
standards, Hultafors can not entirely exclude the
possibility that intense electromagnetic radiation
in the immediate vicinity of radio transmitters,
two-way radios, diesel generators, etc. can
distort the measurement results.
• When performing measurements under these
conditions check the plausibility of the results.
Table des matières
Autres manuels Hultafors Instrument de mesure
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur