Huawei NIP6830 Manuel utilisateur

Issue: 04
Date: 2018-11-07
Part Number:
Quick Start
HUAWEI NIP6830 Network Intelligent Protection System
31508202

Trademarks and Permissions
Copyright © Huawei Technologies Co., Ltd. 2018.All rights reserved.
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Technical Support
Feedback
Huawei support website (http://support.huawei.com/enterprise) is a tool and resource center to resolve product
issues. This website is the recommended first choice for technical support. The website has abundant documents,
covering installation, configuration, maintenance, and more.
You need to register to gain access to more information and resources.
Huawei Technologies Co., Ltd. provides customers with comprehensive technical support. You can contact
Huawei representative offices or headquarters for help.
Your comments and suggestions are important for us to improve documents. You can leave your comments on the
website when you read a document online or email your comments about a document to us.
Notice
The purchased products, services, and features are stipulated by the contract made between Huawei Technolo-
gies Co., Ltd. and the customer. All or part of the products, services, and features described in this document
may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all
statements, information, and recommendations in this document are provided "AS IS" without warranties,
guarantees or representations of any kind, either express or implied.
The information in this document is subject to change due to version upgrade or other reasons. Every effort has
been made in the preparation of this document to ensure accuracy of the contents, but all statements, informa-
tion, and recommendations in this document do not constitute a warranty of any kind, express or implied.
Copyrights
No part of this document may be reproduced or transmitted in any form or by any means without prior writtenconsent
of Huawei Technologies Co., Ltd.
Open Source Software Notice
You can access the device web UI and click Open Source Software Notice at the bottom of the UI to view details of the
open source software notice.
1

Installation Process
1 Preparing the Site
2 Installing the Device
3 Cabling
4 Power-On Check
Connecting Optical Fibers and Network Cables
Connecting AC Power Cables
Connecting DC Power Cables
Installing Fiber Spools
Installing Boards and Daughter Cards
Mounting and Grounding
Installing Cabling Racks and Mounting Ears
Installing Floating Nuts and Guide Rails
5 Configuring Console Access
Power-On Check — AC Power
Power-On Check — DC Power
Installation Checklist
2

Preparing the Site
Before installing the device, ensure that the site meets the following requirements:
If you use a DC cabinet, ensure that the outputs of the DC power distribution box fall within the range of –72 V DC to –38 V
DC. Two different power sources are required for redundancy.
If you use an AC cabinet, ensure that the outputs of the AC power distribution box fall within the range of 90 V AC to 264 V AC.
Two different power sources are required for redundancy.
Airflow clearance: The spacing between the air intake of the cabinet and neighboring objects must exceed 75 mm. If the air
intake of the cabinet is next to another communication device, the spacing must exceed 150 mm.
Maintenance clearance: The spacing between the rear of the cabinet and neighboring objects must exceed 350 mm for
maintenance.
Aisles in the equipment room ≥ 1000 mm; aisles between cabinet rows ≥1000 mm
Spacing between cabinet sides and wall ≥800 mm
Spacing between cabinet row and wall ≥ 1000 mm
Power Supply System
Clearance Requirements
Cabinet Clearance Requirements (Using N68E-22 As an Example)
≥1000mm
800mm
≥1000mm
≥800mm
600mm 600mm 600mm
3

Cabinet size: The height of the NIP6830 is 4 U (1 U = 44.45 mm) for DC cabinet and 5 U for AC cabinet.
Airflow clearance: Maintain a minimum spacing of 2 U between devices installed in the same cabinet, between the top-most
device and the cabinet top, and between the bottom-most device and the cabinet bottom. abinet bottom.
Cabinet Requirements
Installing Floating Nuts and Guide Rails
DC cabinet
AC cabinet
1U
Location of floating nuts for guide rails
M6
The third hole in rack unit 3
(for device)
The first hole in rack unit 6
(for device)
The second hole in rack unit 7
(for fiber spool)
The second hole in rack unit 8
(for fiber spool)
1U
Location of floating nuts for guide rails
M6
The third hole in rack unit 3
(for device)
The first hole in rack unit 7
(for device)
The second hole in rack unit 8
(for fiber spool)
The second hole in rack unit 9
(for fiber spool)
4

Installing Cable Racks and Mounting Ears
Distance L
(between the mounting bar and inside of the front door)
Install the cable racks
Distance L is between 90 mm to 100 mm: Distance L is between 115 mm to 120 mm:
L
1
Before installing the mounting ears,
measure the distance (L) between mount-
ing bar and the front door. The way the
mounting ear is installed depends on
distance L, as shown in the following
figures.
Install the mounting ears
2
M4
Note
M4 M4
5

Before installing the ground cable of the device, ensure that the ground cable of the cabinet is correctly connected and the
ground resistance is zero ohm.
The NIP6830 is heavy and requires two people to lift and move.
Use the handles on the chassis sides when moving the device. Do not use the handles of modules to avoid damages to the
device.
Do not step on the air filter at the bottom of the cabinet.
Warning
Mounting and Grounding
≥18kg(39.7 1b)
M6
6

Before installing boards and daughter cards, ensure that the device and cabinet are adequately grounded.
Before handling a board or daughter card, wear a grounded ESP strap to avoid electrostatic damage to components.
Warning
Slot Assignment
Install a board
1
2
1
2
3
3
Install a daughter card
Installing Boards and Daughter Cards
Determine the slot for the board to be installed based on hardware planning and remove the filler panel from the slot.
Extend the ejector levels of the board, insert the board fully into slot, and rotate the ejector level to the front of the board so
that the board is fully inserted in the slot.
Use a Phillips screwdriver to tighten the captive screws to the board.
Remove the filler panel from the board.
Smoothly insert the daughter card into the board along the guide rail.
Use a Phillips screwdriver to tighten the captive screws to the board.
2 31
1 32
a
b
4/5
3
2
1
AUX
ACT
MPU
NIP-MPU-X3
RUNALM
ACT
RESET
OFL
LINK
CLK TOD MGMT-ETH
CONSOLE AUX
ACT
MPU
NIP-MPU-X3
RUNALM
ACT
RESET
OFL
LINK
CLK TOD MGMT-ETH
CONSOLE
OFF
ON
~100-120V;
~200-240V;
50/60Hz;16A
20
OFF
ON
~100-120V;
~200-240V;
50/60Hz;16A
20
MPU MPU
LPU/SPU
LPU/SPU
LPU/SPU
4 5
3
2
1
7

You are advised to wind excess optical fibers around fiber spools for convenient cable routing and device maintenance.
Determine the locations of the fiber spools based on the device arrangement in the cabinet. The fiber spools cannot be too
close to device operation area to avoid hampering board insertion or removal or cabling, and the fiber spools cannot be too
far away from the device to facilitate fiber spool operation.
Note
Installing Fiber Spools
Install the fiber spool
(left)
Install the fiber spool
(right)
M6
M6
8

Warning
Before installing the power cables, ensure that the device is adequately grounded.
Before connecting the power cable, switch power off on the power distribution box and power module. Do not work on cables
with power to avoid bodily injury or fire.
Connecting DC Power Cables
Air filter Air filter Air filter
To facilitate future maintenance, observe the following cabling requirements:
High touch current,earth connection essential
before supply and/or telecommunication
network connections
WARNING 大接触电流,
在连接电源盒通信网络之前均须先接地
Air Filter
Refer to diagram of
cable routing.The air
filter can not be
covered by cables.
请按示意图走线,
线缆不得遮挡防尘网
STATUS
Don’t touch the
fan leaves before
they slow down.
严禁在风扇高速
旋转时接触扇叶
RUN
NEG(-)
RTN(+)
ALM
ON
OFF
OFF
ON
-48~-60V;42A
RUN
NEG(-)
RTN(+)
ALM
ON
OFF
OFF
ON
-48~-60V;42A
Power A
A1(-) A1(+) A2(-) A2(+) B1(-) B1(+) B2(-) B2(+)
Power B
Power A A1(-) PWR0 NEG(-)
PWR0 RTN(+)
Power A A1(+)
Power B B1(-) PWR1 NEG(-)
PWR1 RTN(+)
Power B B1(+)
From To
Power A A1(-) Power A A1(+)
PWR0 RTN(+)
PWR0 NEG(-)
PWR0
PWR1
a
a
b
b
Cables of the power modules must be tied separately to facilitate the removal of individual modules.
Ensure that the power cables do not block the air filter and that the cables of one power module do not block the access
to the cables of the other module.
After you connect power cables, install the plastic cover of the junction boxes.
9
Table des matières
Autres manuels Huawei Pare-feu

Huawei
Huawei HiSecEngine USG6000F Series Manuel utilisateur

Huawei
Huawei USG6000 Series Instructions d'installation

Huawei
Huawei USG6306 Manuel utilisateur

Huawei
Huawei USG6000E Series Instructions d'installation

Huawei
Huawei Quidway Eudemon 200 Manuel utilisateur

Huawei
Huawei Eudemon8000E Series Manuel utilisateur

Huawei
Huawei USG6000 Series Manuel d'installation et d'exploitation

Huawei
Huawei USG9500 Series Instructions d'installation

Huawei
Huawei USG9500 Series Instructions d'installation