HTechMT CO600 Series Manuel utilisateur

CO600 Coating Thickness Gauge
─ 1 ─
HTechMT CO600
Coating Thickness Gauge
Content
1. Overview .......................................................................................................................... 1
2. Construction Plan ........................................................................................................... 1
3. Packing List ..................................................................................................................... 2
4. Before First Use .............................................................................................................. 2
5. On Screen ........................................................................................................................ 3
6. Measurement Procedure ............................................................................................... 4
7. Calibration ........................................................................................................................ 4
8. Upper/Lower Limit Setting ............................................................................................. 5
9. Statistics ........................................................................................................................... 6
10. Language, Volume, Screen Rotation and Restore Factory Setting ........................ 6
11. Notice ................................................................................................................................ 6
12. Technical Data ................................................................................................................ 7
13. Configuration of Different Models ................................................................................. 7
14. Typical Problems ............................................................................................................ 8
15. Accessories ..................................................................................................................... 9
16. Menu Diagram ............................................................................................................... 10

CO600 Coating Thickness Gauge
─ 1 ─
1. Overview
CO600 series coating thickness gauge is designed to determine the thickness
of a magnetically non-conductive coating on ferrous substrates, or the thickness
of an electrically non-conductive coating on non-magnetic metal substrates.
Standards: ISO 2178/2360/2808, ISO 19840, ASTM B244/B499/D1186/D1400,
BS3900-C5
2. Construction Plan
1. Strap hole 10. Probe socket
2. Light sensor 11. Probe
3. LED indicator (pluggable for separate type)
4. Screen 12. USB socket cover
5. Function keys 13. Screw
6. On/Off key 14. Label position
7. Upper hand grip position 15. Back panel
8. Front panel 16. Screw for battery cover
9. Lower hand grip position 17. Battery cover

CO600 Coating Thickness Gauge
─ 2 ─
3. Packing List
1. CO600 gauge (probe NOT included for separate type)
2. Silicon case
3. Standard film set (NOT for separate type)
4. Zero plate
5. AA battery, 2 pieces
6. Operation manual
7. Certificate
4. Before First Use
1. Check the package according to the packing list.
2. Install battery: release the screw and remove the cover. Insert 2 AA batteries
and then fix the cover. Note that the battery should be removed when not in
use for long periods. Renew the battery if the indicator shows 20% or less.
3. For separate type, install the probe according to the diagram below. Note
that the probe may be inserted only when the gauge is OFF.

CO600 Coating Thickness Gauge
─ 3 ─
5. On Screen
1. Statistics
N: Number of measurements; Max: Maximum;
Min: Minimum; AVG: Average; σ: Standard deviation;
2. USB: appears when connected with a computer.
3. Battery level, turns red when lower than 20%.
4. Fe: Ferrous substrate; NFe: Non-ferrous substrate
5. Calibration method
2 point calibration, smooth
Zero calibration
2 point calibration, rough
Factory calibration
6. Upper/Lower limit: symbol appears when the limit setting was switched on.
7. Exceeding Upper/Lower limit
Upper limit exceeded
Lower limit exceeded
8. Unit: mm, μm, mils or inch
9. Measurement data, displayed in white normally, shown in red when upper
or lower limit exceeded.
10. Menu
Including Calibration, Clear, Volume, Setting, Language, Screen Rotation
etc., see menu diagram for details.

CO600 Coating Thickness Gauge
─ 4 ─
6. Measurement Procedure
1. Long press the On/Off button to turn the gauge on.
2. Check the specimen and select a suitable calibration method. Calibrate
accordingly and the latest calibration will be stored and applied as a rule.
3. Set upper or lower limit when necessary.
4. Set statistics, storage and adjust other settings when necessary.
5. Start measurement. Note that the probe should be put perpendicular to the
surface to be measured to minimize measurement error.
6. Turn off the gauge after measurement by long press the On/Off button.
7. Calibration
1. Types of calibration
1) Zero calibration: single point, use the zero plate directly.
2) 2 point calibration, smooth: suitable for coatings on smooth surface.
3) 2 point calibration, rough, method 1: recommended for sand- or shot-
blasted surfaces with roughness of less than 55-65 µm. Calibration
should be done directly on the blasted surface without coating.
4) 2 point calibration, rough, method 2: recommended for sand- or shot-
blasted surfaces with roughness of more than 55-65 µm. Calibration
should be done directly on the blasted surface without coating.
5) Factory calibration, can be reset by restoring factory setting.
Note: As to the selection of standard film, one that is slightly thicker than the
coating to be measured should be used for calibration. For example, for a
coating of about 80 µm, a standard film of 125 µm should be applied for
calibration.

CO600 Coating Thickness Gauge
─ 5 ─
2. Procedure of calibration
1) Click “Calibration”, select types needed, for example, “2-point calibration,
smooth”.
2) Put selected standard film on zero plate (other substrate may be used
according to calibration method) and measure the thickness.
3) If the result differs from that of the standard film, correct it using upward
or downward arrow, and then click “Next”.
4) Put the probe on the zero plate and measure the thickness.
5) Click “Zero” to zero the gauge.
6) When “2-point calibration, smooth, finished” appears on the screen, click
“OK”.
7) Calibration finished.
Note: It is recommended that the calibration be performed with blasted
substrate as support for standard films in case of: (1) thin substrates of less
than 0.8 mm (ferrous) or 0.3 mm (non-ferrous); (2) tubes or curved
substrates especially those with small diameters.
8. Upper/Lower Limit Setting
1. Click “Menu”.
2. Select Upper/Lower limit.
3. Select “On” or “Off”.
4. Select “Upper limit” or “Lower limit” and click “OK”.
5. Set the limit using upward or downward arrows. Note that the upper limit
should be larger than the lower limit.
6. Select “Save and Exit”, and then click “OK” to finish.

CO600 Coating Thickness Gauge
─ 6 ─
9. Statistics
Statistics is always running, and the analysis is based on the data since the last
selection of “Clear and start new statistics”. The results of statistics won’t loss
after turning off the gauge. However, only the last five measurement results can
be displayed.
1. Select “Menu” on the main screen, and then select “Statistics”.
2. Select “On” or “Off” to turn on or off the display of statistical results on the
top-left corner of the main screen.
3. Select “Clear” and then “Clear and start new statistics” to clear available
data and start new statistics.
10. Language, Volume, Screen Rotation and Restore
Factory Setting
1. Can all be adjusted using the “Menu” on main screen.
2. Shortcut for language: press the second button from left long.
3. Shortcut for volume: press the third button long.
4. Screen rotation: auto-rotation can be turn on or off.
5. Factory settings: Language (English), Unit (µm), Screen Rotation (On),
Volume (max), Brightness (max).
11. Notice
1. In case of contact with water, turn off the gauge, remove the battery
immediately and then dry the gauge properly.
2. Contamination like paint, dust and iron fillings etc. in the space between the
probe and the socket should be removed immediately to avoid locking.

CO600 Coating Thickness Gauge
─ 7 ─
3. Contaminations on the tip of the probe such as paint and dust etc. can be
removed by carefully applying a cutter blade.
4. The cable of the probe should be stored properly, and sharp bending should
be avoided.
12. Technical Data
Dimension 70 X 150 X 32 mm
Weight 200 g (including batteries)
Screen 2.2 TFT
Battery AA size, 2X, rechargeable ones applicable
Battery life time 20 hours typically, may vary with operating conditions
Operating temperature -10 to 50 oC
Precision ±3%
Measurement speed Up to 60 times per minute
13. Configuration of Different Models
Economic Basic
Standard Top
Setting
Low power alarm ◆ ◆ ◆ ◆
Language ◆ ◆ ◆ ◆
Light sensor ◆ ◆ ◆ ◆
Screen autorotation ◆ ◆ ◆
Volume adjustment ◆ ◆ ◆
Display brightness ◆ ◆ ◆
Calibration
2-point calibration, smooth ◆ ◆ ◆ ◆
2-point calibration, rough, 1
◆ ◆ ◆
2-point calibration, rough, 2
◆ ◆ ◆
Zero calibration ◆ ◆ ◆
Factory calibration ◆ ◆ ◆ ◆

CO600 Coating Thickness Gauge
─ 8 ─
Economic Basic
Standard Top
Statistics
On-screen statistics ◆ ◆ ◆
Measurement number ◆ ◆ ◆
Maximum value ◆ ◆ ◆
Minimum value ◆ ◆ ◆
Average ◆ ◆ ◆
Standard deviation ◆ ◆ ◆
Batches
New batch ◆ ◆
Open batch ◆ ◆
View batch ◆ ◆
Clear batch ◆ ◆
Delete batch ◆ ◆
Exit batch ◆ ◆
Number of batch (max) 10 100
Others
Upper/Lower limit alarm ◆ ◆ ◆
Storage capacity 100,000 1,000,000
USB to PC ◆ ◆ ◆ ◆
Hardware update ◆ ◆ ◆ ◆
WIFI ◆ ◆
14. Typical Problems
Failure Possible reason Measures
Cannot turn
the gauge on
Battery empty, or battery
inserted in wrong direction
Check battery
Fluctuating
measurement
results
Calibration not done
properly
Repeat calibration according to
above-mentioned procedure
The tip of the probe
contaminated.
Clean the tip of the probe with
a cutter blade
Probe blocked Contamination or rust Wet with suitable solvents or
apply rust spray
Other problems Contact manufacturer or dealer
Ce manuel convient aux modèles suivants
4
Table des matières
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur