OPERATOR’S MANUAL
FUSION IQ™

HOTRONIX®
FUSION IQ™Safety Instructions
When using your heat press, basic precautions should always
be followed, including the following:
1. Read all instructions.
2. Use heat press only for its intended use.
3. To reduce the risk of electric shock, do not immerse the heat press in water or other liquids.
4. Never pull cord to disconnect from outlet, instead grasp plug and pull to disconnect.
5. Do not allow cord to touch hot surfaces, allow heat press to cool completely before storing.
6. Do not operate heat press with a damaged cord or if the equipment has been dropped or damaged.
To reduce the risk of electric shock, do not disassemble or attempt to repair the heat press. Take it to
a qualified service person for examination and repair. Incorrect assembly or repair could increase the
risk of fire, electric shock, or injury to persons when the equipment is used. Power supply cord must
be disconnected before cleaning or servicing press.
7. This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
8. Close supervision is necessary for any heat press being used by or near children. Do not leave equipment
unattended while connected.
9. To avoid burns, do not touch hot metal parts or the heated platen during use.
10. To reduce the likelihood of circuit overload, do not operate other high voltage equipment on the same circuit.
11. If an extension cord is necessary, then a 20-amperage rated cord should be used. Cords rated for less
amperage may overheat. Care should be taken to arrange the cord so that it cannot be pulled or tripped over.
12. Keep hands clear of the upper heat press platen during lock down as the pressure may cause injury.
13. Heat press should be placed on a sturdy, suitable stand at least 36"L x 24"W x 29"H.
14. Work area must be kept clean, tidy and free of obstructions.

Safety Instructions Table Of Contents
When using your heat press, basic precautions should always
be followed, including the following:
Safety Instructions
Machine View
Operating Instructions
Connecting the System
Start Up/Shut Down
Home Screen
Prepare to Print
Touch Screen Guide
Setup Menu
Password Setup
Preset Setup
Date & Time Setup
Display Setup
Auto On & Off Setup
System Setup
Calibration
Updating Software
Connecting to the IQ™Portal
Electrical Schematic
Replacement Parts List
Contact
2
4
5-7
5
5
6
7
8-11
8
8
9
10
10
10
10
11
11
12
13
14-15
16

SERVICE HOTLINE: 800.727.85204
HOTRONIX®
FUSION IQ™Machine View
ON OFF
Touch Screen
Lift Handle
Over-the-Center
Pressure Adjustment Knob
Power ON/OFF Switch
Circuit Breaker
IEC Inlet
Swing Lock
Heat Platen
Swing Handle
Pull Handle
Lower Platen
Base

5WWW.HOTRONIX.COM
Machine View Operating Instructions
Insert power cord into IEC inlet located in the back of the press (1.1).
Connect the power cord into a properly grounded electrical outlet
with a sufficient amperage rating.
NOTE: To release power cord from press, hold two red buttons
on both sides of cord and pull (1.2).
Voltage
120 volt requires a full 20-amp
grounded circuit for 120-volt operation.
220 volt requires a full 10-amp
grounded circuit for 220-volt operation.
Connecting the System
To start up your heat press:
Flip the power switch ON (2.1). A splash screen displaying
the Hotronix®logo and current software version is shown for
several seconds.
To turn your heat press off, flip the power switch OFF.
To place your heat press into Standby Mode, touch and release
the Power icon on the Home Screen (3.2). In Standby Mode, the
heater turns off while the Touch Screen remains on, displaying
an orange background as a warning if the platen is still hot
(above 100°F / 38°C).
NOTE: Standby Mode must be used for the Auto On feature to function
(10.1). The Auto On feature will not work if the power switch (2.1) is in
the OFF position.
To start up your heat press while in Standby Mode,
touch and release the Home icon on the Standby Screen.
Start Up/Shut Down
1.1
1.2
2.1

SERVICE HOTLINE: 800.727.85206
HOTRONIX®
FUSION IQ™Operating Instructions
Displays the selected
preset. Touch and
hold to see application
settings.
NOTE: Holding down material
name will display targeted
application settings. Screen
displays current temperature,
pressure, and time.
Status bar provides
helpful information
regarding heat press.
Displays multiple heat
application preset step.
Touch the empty circled
numbers to switch
between preset steps.
Touch and edit your
favorite presets.
IQ™Portal and WIFI
connection status.
Lock the screen
(Manager-level only)
to prevent User-level
operators from
changing settings.
Touch and edit Users to
control operator access
level and track press
usage by operator in the
IQ™Portal.
Displays the current application
temperature and time. To view
pressure, touch 0 and target
pressure is displayed. Manual
pressure adjustment required.
Home Screen
3.1
3.2
Touch
Setup menu.
Place press in Standby Mode
to take advantage of the
scheduled Auto On feature.

7WWW.HOTRONIX.COM
Operating Instructions
To begin heat applying, start by verifying that you have
the proper settings displayed on the Home Screen.
•Select preset material application.
•Manually enter temperature and time for selected
material. Adjust pressure accordingly.
When desired settings are reached, you can begin heat application.
When using the Swing feature (4.1), swing the heat platen outward
and position the garment and design.
When using the Draw feature (4.2), pull out the lower platen and
position the garment and design.
Swing or push the platen back into position and lower platen to heat apply.
The Home Screen will initiate a count down and signal when to lift
the platen off the garment.
Swing or pull the heat platen and proceed according to the application instructions.
Prepare to Print
4.2
4.1

SERVICE HOTLINE: 800.727.85208
HOTRONIX®
FUSION IQ™
Touch the Settings icon on
the Home Screen (5.1)
to configure your heat press.
Managers can access all setup
options, while Users can access
a limited set (5.2).
•Managers default password: M
Touch the User icon on the
Home Screen (6.1) or Setup
Menu (6.2) to select, add,
and edit Users.
Touch and edit Managers
and Users to configure
access to settings (6.3, 6.4).
Heat press reports on the
IQ™Portal can be filtered
by User to track individual
operator performance.
Touch the arrow keys on the
taskbar to scroll through a
long list of Users (6.5).
Setup Menu
Password Setup (Manager Level Only)
5.1 5.2
6.1 6.2
6.3 6.4
6.5
Touch Screen Guide

9WWW.HOTRONIX.COM
Touch the Columns icon (7.1)
to select from a list of saved
presets (7.2).
Touch the arrow keys on the
taskbar to scroll through a
long list of presets (7.3).
Touch a preset to select
a material.
Touch the Pencil icon (7.4) to
enter edit mode, then touch
preset name to edit settings.
Touch Enter to save changes.
Touch the Plus icon to create
a new preset (7.5).
Name your preset and
enter desired temperature,
time, and pressure. When
creating a new preset,
the current Home Screen
application settings are
selected automatically (7.6).
Touch the empty circled
numbers to set multiple preset
stages for pretreatment or
multi-step applications (7.7).
Preset Setup
7.1 7.2
7.3
7.67.5
7.7
7.4

SERVICE HOTLINE: 800.727.852010
HOTRONIX®
FUSION IQ™
Touch the Settings icon on the Home Screen.
•Touch Date & Time, information displays on right of screen (8.1).
•Touch up/down arrows to select time zone.
•Touch Auto to automatically synchronize the heat press clock.
The heat press must be connected to a WIFI network with
access to the Internet.
•Touch Daylight Saving to enable daylight saving mode.
This option should be enabled during summer.
Date & Time Setup
Touch the Settings icon on the Home Screen.
•Select System, information displays on right of screen (11.1).
•Touch Power Save and select time, then touch Check Mark icon
on taskbar to save.
•When enabled, your heat press will enter Standby Mode if it is not
used for the specified number of hours.
System Setup (Manager Level Only)
Touch the Settings icon on the Home Screen.
•Touch Display, information displays on right of screen (9.1).
•Touch Temperature to switch between F° or C°, then touch
Check Mark icon on taskbar to save.
Display Setup
Touch the Settings icon on the Home Screen.
•Touch Auto On/Off, information displays on right of screen (10.1).
•Touch Enable, then On Hour/Minute and Off Hour/Minute,
selecting Enter between each setting. Once entered,
touch Check Mark icon on taskbar to save.
NOTE: Standby Mode must be used for the Auto On feature to function (3.2).
The Auto On feature will not work if the power switch (2.1) is in the OFF position.
Auto On & Off Setup
8.1
9.1
10.1
11.1
Touch Screen Guide
Autres manuels pour FUSION IQ
2
Table des matières
Autres manuels Hotronix Outils électriques

Hotronix
Hotronix 360 IQ HAT PRESS Manuel utilisateur

Hotronix
Hotronix FUSION IQ Manuel utilisateur

Hotronix
Hotronix Auto Open 6x6 Manuel utilisateur

Hotronix
Hotronix STXBP-120 Manuel utilisateur

Hotronix
Hotronix MAXX 11x15 Manuel utilisateur

Hotronix
Hotronix CP912-120 Manuel utilisateur

Hotronix
Hotronix MAXX Manuel utilisateur

Hotronix
Hotronix FUSION IQ Manuel utilisateur