HIBLOW HP Series Manuel utilisateur

1
HP-60/80
HP
HP Series
STRUCTURE AND PART NAMES
HP-60/80
HP-60
HP-80
1995/9
1995/9
─
─
HP-60/80
漓 Filter Cover
滷 Air Filter Gasket
澆 Air Filter
潺 Fitting Boss
潸 Upper Housing
澁 Silencer Wrap
澀 Casing Block
潯 Diaphragm Ring
潛 Diaphragm
濳 Diaphragm Mounting
潭 SP Switch
澂
SP Swwitch Screw
潼 Electromagnet
潘 Actuating Rod
澎 Internal L-Tube
澑 Hose Clamp
濂 Frame
潦
Vibration Control Rubber
澳 Center Plate
澣 Base Gasket
澡 Lower Housing
澤 Power Cord
Air pump Start of production
Discontinuance of production
Goodies Wastewater Supplies
Phone: 1300 282 181 Fax: 1300 282 989
PO Box 1524, Oxenford QLD 4210 35 Scenic Cr, Coomera QLD 4209
Email: [email protected] Web: www.goodies.net.au

2
HP
ReplacingtheChamberBlock
HP-
60/80
REPLACING THE CHAMBER BLOCK
●Besuretounplugthepumpunit.
●Replacethediaphragmsandthevalveswithnewonesatleastonceayeartooneand
ahalfyearregularlyinordertomaintaintheirinitialperformance.
●Forchamberblockreplacement,besuretochangebothchamberblocksatthesametime.
●The rod employs powerful permanent magnets. Therefore, be sure to remove your
watchandanyotherprecisionmachinesbeforeoperationastheymaybeaffectedby
thestrongmagneticforce.
●Donotputtheactuatingrodclosetoamagneticcard,magneticdiskorothermagnetic
mediaasthedatamaybedestroyed.
STEP
1
STEP
1
Toremovetheupperhousing.
(RefertoREMOVING UPPER HOUSING)
Removethesoundabsorber.
PullouttheL-tubefromthecasingblock.
STEP
2
STEP
2
Removethe4screwsholdingthechamberblock
andthecasingblock.
(4screwsoneachside)
STEP
3
STEP
3
Remove 1 U-lock nuts from one side holding the
diaphragmmountingblocktotherod.
●Usethenutdrivertoloosen(ortighten)theU-locknut.
REMOVAL OF THE CHAMBER BLOCKS
CAUTION!
Goodies Wastewater Supplies
Phone: 1300 282 181 Fax: 1300 282 989
PO Box 1524, Oxenford QLD 4210 35 Scenic Cr, Coomera QLD 4209
Email: [email protected] Web: www.goodies.net.au

3
ReplacingtheChamberBlock
HP
HP-
60/80
REPLACING THE CHAMBER BLOCK
STEP
4
STEP
4
STEP
5
STEP
5
STEP
6
STEP
6
Inserttheactuatingrodintothemachinebody.Be
suretofitthepositioningbossonthediaphragm
baseintotheconcavepartoftheframestay.
Secure the diaphragm mounting block on the
other side and tighten washers and U-lock nuts
withthenutdriver.
Make sure that gap between the actuating rod
andtheelectromagnetsiseven.
Removeoneofthediaphragmmountingblocksfrom
the actuating rod and pull out the other diaphragm
mountingblockwiththerod.Afterthat,separatethe
diaphragmmountingblockandtherod.
●Whenpullingouttherod,besurenottocatchtherod
projectionontheleveroftheSPswitch.
●Ifthepumpstopsautomatically,thesafetypinmustbebrokentopreventany
furtherdamagetothepump.Besureallbrokenpiecesareremovedfromthe
unit.(SeeStep8)
STEP
7
STEP
7
Mount the casing block with screws (4screws on
eachside).
AndinsertL-tubeintothenozzleofcasingblock.
Completetheothercasingblockatthesameway.
Fittheactuatingrodbyaligningitwiththegroove
andtightenU-locknutandflatwasherbythenut
driver.
●UsenewU-locknutandwasher,otherwise,U-locknut
mayworklooseandcausemalfunction.
FITTING THE CHAMBER BLOCKS
Goodies Wastewater Supplies
Phone: 1300 282 181 Fax: 1300 282 989
PO Box 1524, Oxenford QLD 4210 35 Scenic Cr, Coomera QLD 4209
Email: [email protected] Web: www.goodies.net.au

4
HP
ReplacingtheChamberBlock
STEP
8
STEP
8
Checkthatthebrokenscrewisremovedfromunit.
●Ifthebrokenpinisleftinsidetheunit,itcangetcaught
in between electromagnets and actuating rod, which
cancausebreakdown.
STEP
9
STEP
9
Insert a new safety pin through the hole on the
terminalside.
(Please Insert safety pin through the spring
electrode,L-shapedleverinsuchorder.)
STEP
10
STEP
10
Installthelockingcollarfromtheothersideofthe
terminalandinsertituntilitclicks.
STEP
11
STEP
11
This completes the replacement of the safety pin
procedure.
Make sure the gaps between L-shaped lever and
taboftheactuatingrodiseven.
●Becarefulnottotouchtheterminalwhenthepoweris
on,testingtheoperatingconditionsasthiswillresultin
anelectricshock.
●Unplugthepumpimmediatelyafterthecheck.
HP-
60/80
REPLACING THE CHAMBER BLOCK
REPLACEMENT OF SAFETY PIN
Goodies Wastewater Supplies
Phone: 1300 282 181 Fax: 1300 282 989
PO Box 1524, Oxenford QLD 4210 35 Scenic Cr, Coomera QLD 4209
Email: [email protected] Web: www.goodies.net.au

5
ReplacingtheChamberBlock
HP
HP-
60/80
REPLACING THE CHAMBER BLOCK
STEP
12
STEP
12
STEP
13
STEP
13
Placetheupperhousingbackonbody.
●Be extremely careful not to catch the sound absorber
ontheupperhousing.
Fastenitwiththebolts.
Then,placethefilterandfiltercoverontheupper
housing. (Refer to FILTER CLEANING AND
REPLACEMENT)
Installthesoundabsorber.
Goodies Wastewater Supplies
Phone: 1300 282 181 Fax: 1300 282 989
PO Box 1524, Oxenford QLD 4210 35 Scenic Cr, Coomera QLD 4209
Email: [email protected] Web: www.goodies.net.au

6
HP
ReplacingtheElectromagnet
HP-
60/80
REPLACING THE ELECTROMAGNET
●Besuretounplugthepumpunit.
●Whenperformingreplacement work, the pumpbodymaystillbe hot and youcould
getburned.Sopleasewaituntilthepumphascooledbeforehandling.
●Be sure to remove the chamber block and the actuating rod before replacing the
electromagnet.
●It is better to let an experienced technician handle the soldering process. Take
precautionsagainstgettingburned.
STEP
1
STEP
1
Cut the wire from terminals on the electromag-
netswithnippers.
●Itisrecommendedthatyoumakeanoteofthewiring.
STEP
2
STEP
2
Loosenthescrew,fixingSPswitchandremoveit.
(There are hexagonal nuts at SP switch side. Be
surenottolosethemastheyfallinsidetheunit.)
STEP
3
STEP
3
Removethehexagonalnutsbythenutdriver.
(7mmwrench)
Pullouttheelectromagnetsfromthepumpbody.
CAUTION
!
REMOVAL OF ELECTROMAGNET
Goodies Wastewater Supplies
Phone: 1300 282 181 Fax: 1300 282 989
PO Box 1524, Oxenford QLD 4210 35 Scenic Cr, Coomera QLD 4209
Email: [email protected] Web: www.goodies.net.au

7
ReplacingtheElectromagnet
HP
HP-
60/80
REPLACING THE ELECTROMAGNET
STEP
4
STEP
4
STEP
5
STEP
5
STEP
6
STEP
6
Insertthewireintothesilicontube,andtieupina
bundle.
Stripthecoatingoffeachwire.
(5-7mmfromtheend)
Connectthewirestotheterminals.
Solderthewirestotheterminals.
Thewirerequiresasolderedconnection.
Mountnewelectromagnetintheunit.
Tightenuphexagonalnutswithnutdriver.
STEP
7
STEP
7
This completes the electromagnet replacement
procedure.
InstalltheSPswitchtotheframewiththescrews.
●Becarefulofthedirectionofswitchlever.(Refertothe
pictures)
MOUNTING THE ELECTROMAGNET
Goodies Wastewater Supplies
Phone: 1300 282 181 Fax: 1300 282 989
PO Box 1524, Oxenford QLD 4210 35 Scenic Cr, Coomera QLD 4209
Email: [email protected] Web: www.goodies.net.au
Autres manuels pour HP Series
3
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels HIBLOW Pompe à eau
Manuels Pompe à eau populaires d'autres marques

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guide de dépannage

DUROMAX
DUROMAX XP WX Series Manuel utilisateur

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuel utilisateur

Franklin Electric
Franklin Electric IPS Manuel utilisateur

Xylem
Xylem e-1532 Series Manuel utilisateur

Milton Roy
Milton Roy PRIMEROYAL Manuel utilisateur