HOBOMX2300SeriesDataLoggerManual
1‐800‐LOGGERS6www.onsetcomp.com
4. SelectLowand/orHighandeithertypeordragthesliderto
setthelowand/orhighvalues.TapDoneinHOBOmobile.
5. Repeatstep4fortheothersensorifdesired.
6. TapDoneandrepeatsteps4–7fortheothersensorif
desired.
7. Settheburstlogginginterval,whichmustbefasterthanthe
logginginterval.Keepinmindthatthefastertheburst
loggingrate,thegreatertheimpactonbatterylifeandthe
shortertheloggingduration.Becausemeasurementsare
beingtakenattheburstloggingintervalthroughoutthe
deployment,thebatteryusageissimilartowhatitwouldbe
ifyouhadselectedthisrateforthenormallogginginterval.
TapDoneinHOBOmobile.
8. TapDoneorSave.
9. TapStartinHOBOmobileorinHOBOconnect.
Notes:
Thehighandlowburstlimitsarecheckedattheburst
loggingintervalratewhethertheloggerisinnormalor
burstcondition.Forexample,iftheloggingintervalisset
to1hourandtheburstloggingintervalissetto10
minutes,theloggerwillalwayscheckforburstlimits
every10minutes.
Ifhighand/orlowlimitshavebeenconfiguredformore
thanonesensor,thenburstloggingwillbeginwhenany
highorlowconditiongoesoutofrange.Burstloggingwill
notenduntilallconditionsonallsensorsarebackwithin
normalrange.
Theactualvaluesfortheburstlogginglimitsaresetto
theclosestvaluesupportedbythelogger.
Burstloggingcanbeginorendwhenthesensorreadingis
withintheresolutionspecifications.Thismeansthevalue
thattriggersburstloggingmaydifferslightlythanthe
valueentered.
Oncethehighorlowconditionclears,thelogging
intervaltimewillbecalculatedusingthelastrecorded
datapointinburstloggingmode,notthelastdatapoint
recordedatthenormalloggingrate.Forexample,the
loggerhasa10‐minuteloggingintervalandloggedadata
pointat9:05.Then,thehighlimitwassurpassedand
burstloggingbeganat9:06.Burstloggingthencontinued
until9:12whenthesensorreadingfellbackbelowthe
highlimit.Nowbackinnormalmode,thenextlogging
intervalwillbe10minutesfromthelastburstlogging
point,or9:22inthiscase.Ifburstlogginghadnot
occurred,thenextdatapointwouldhavebeenat9:15.
ANewIntervaleventiscreatedeachtimethelogger
entersorexitsburstloggingmode.SeeLoggerEventsfor
detailsonplottingandviewingtheevent.Inaddition,if
theloggerisstoppedwithabuttonpushwhileinburst
loggingmode,thenaNewIntervaleventisautomatically
loggedandtheburstconditioniscleared,evenifthe
actualhighorlowconditionhasnotcleared.
StatisticsLogging
Duringfixedlogging,theloggerrecordsdataforenabled
sensorsand/orselectedstatisticsatthelogginginterval
selected.Statisticsarecalculatedatasamplingrateyouspecify
withtheresultsforthesamplingperiodrecordedateach
logginginterval.Thefollowingstatisticscanbeloggedforeach
sensor:
Themaximum,orhighest,sampledvalue,
Theminimum,orlowest,sampledvalue,
Anaverageofallsampledvalues,and
Thestandarddeviationfromtheaverageforallsampled
values.
Forexample,aloggerisconfiguredwithboththetemperature
andRHsensorsenabled,andtheloggingintervalsetto5
minutes.TheloggingmodeissettofixedloggingwithNormal
andallfourstatisticsenabledandwithastatisticssampling
intervalof30seconds.Onceloggingbegins,theloggerwill
measureandrecordtheactualtemperatureandRHsensor
valuesevery5minutes.Inaddition,theloggerwilltakea
temperatureandRHsampleevery30secondsandtemporarily
storetheminmemory.Theloggerwillthencalculatethe
maximum,minimum,average,andstandarddeviationusingthe
samplesgatheredovertheprevious5‐minuteperiodandlog
theresultingvalues.Whenreadingoutthelogger,thiswould
resultin10dataseries(notincludinganyderivedseries,such
asdewpoint):twosensorseries(withtemperatureandRH
dataloggedevery5minutes)pluseightmaximum,minimum,
average,andstandarddeviationseries(fourfortemperature
andfourforRHwithvaluescalculatedandloggedevery5
minutesbasedonthe30‐secondsampling).
Tologstatistics:
1. TaptheDevicesicon(inHOBOmobile,tapLoggersatthe
topofthescreen).Taptheloggerintheapptoconnectto
it.IftheloggerwasconfiguredwithBluetoothAlwaysOn
disabled,pressthebuttonontheloggertowakeitup.
Whenworkingwithmultipleloggers,youcanalsopressthe
buttonontheloggertobringittothetopofthelist.
2. TapConfigureinHOBOmobileortapinHOBOconnect.
3. TapLoggingModeandthenselectFixedIntervalLoggingin
HOBOmobileorFixedLogginginHOBOconnect.
4. SelectNormaltorecordthecurrentreadingforeach
enabledsensorattheloggingintervalshownatthetopof
thescreen.Donotselectthisifyouonlywanttolog
statistics.
5. Selectthestatisticsyouwanttheloggertorecordateach
logginginterval:Maximum,Minimum,Average,and
StandardDeviation(averageisautomaticallyenabledwhen
selectingStandardDeviation).Statisticswillbeloggedforall
enabledsensors.Inaddition,themorestatisticsyourecord,
theshortertheloggerdurationandthemorememoryis
required.
6. TapStatisticsSamplingIntervalandselecttheratetouse
forcalculatingstatistics.Theratemustbelessthan,anda
factorof,thelogginginterval.Forexample,ifthelogging
intervalis1minuteandyouselect5secondsforthe
samplingrate,thentheloggerwilltake12samplereadings
betweeneachlogginginterval(onesampleevery5seconds
foraminute)andusethe12samplestorecordtheresulting
statisticsateach1‐minutelogginginterval.Notethatthe
fasterthesamplingrate,thegreatertheimpactonbattery
life.Becausemeasurementsarebeingtakenatthestatistics
samplingintervalthroughoutthedeployment,thebattery
usageissimilartowhatitwouldbeifyouhadselectedthis