HESA TCN-11SDDN Manuel utilisateur

1/36
User Manual
IP CA M E R A
TCN-11SDDN
(COD. KUNTC11SD)
DT01845HE0510R00

2/36
WARINGS
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS
PRODUCT TO RAIN OR MISTURE.
DO NOT INSERT ANY METALLIC OBJECT THROUGH VENTILATION GRILLS.
CAUTION
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION_TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
COPYRIGHT
THE TRADEMARKS MENTIONED IN THE MANUAL ARE LEGALLY REGISTERED
TO THEIR RESPECTIVE COMPANIES.

3/36
Content
I. PREFACE.............................................................................................................................................. 4
II. PRODUCT SPECIFICATIONS............................................................................................................. 4
III. PRODUCT INSTALLATION ................................................................................................................. 6
A. MONITOR SETTING ............................................................................................................................................6
B. HARDWARE INSTALLATION AND I/O PIN ASSIGNMENT ....................................................................................7
C. IP ASSIGNMENT .................................................................................................................................................8
D. INSTALL ACTIVEX CONTROL:..........................................................................................................................10
IV. LIVE VIDEO ........................................................................................................................................ 12
V. CONFIGURATION .............................................................................................................................. 14
A. SYSTEM............................................................................................................................................................15
B. NETWORK ........................................................................................................................................................18
C. A/V SETTING ...................................................................................................................................................24
D. EVENT LIST......................................................................................................................................................30
VI. NETWORK CONFIGURATION.......................................................................................................... 33
VII. FACTORY DEFAULT .......................................................................................................................... 35
VIII. PACKAGE CONTENTS ..................................................................................................................... 35
APPENDIX I ................................................................................................................................................. 35

4/36
I. Preface
This is a professional CCD IP camera with the web server built in. User can view
real-time video via IE browser. It supports MPEG-4 & JPEG video compression
which provides smooth and high video quality. The video can be stored in the SD
card and playback remotely.
With user friendly interface, it is an easy-to-use IP camera which is designed for
security application.
II.Product Specifications
True Day/Night IR Cut Filter
MPEG4/JPEG compression
Supports SD card for local recording
2-way audio
Support Cell phone/PDA
Online firmware upgrade
Compatible with Microsoft Windows Media Player
Specifications
Hardware
CPU ARM 9 ,32 bit RISC
SDRAM 64MB
Flash 8MB
Image sensor 1/3” CCD
Sensitivity Hi-Res at 0.1 Lux, Mid-Res at 0.05 Lux
Lens Changeable Yes, CS Mount
Support DC IRIS Yes
I/O 2 in/ 2out
RS-485 Yes
Video Out 1
Microphone Built-in
Audio Out 1
Power Consumption LAN_DC 12V, 450mA; WLAN_DC 12V,
550mA
Dimensions (W_H_D) 58 x 65 x 131.5 mm
Network
Ethernet 10/ 100 Base-T

5/36
Network Protocol HTTP, TCP/ IP, SMTP, FTP, PPPoE, DHCP,
DDNS, NTP
Wireless (Optional)
Wireless 802.11b/g
WEP 64/ 128 bit
System
NTSC_720x480, 704x480,352x240, 176x120
Video Resolution PAL_720x576, 704x576,352x288, 176x144
Video adjust Brightness, Contrast, Saturation, Hue
CCD setting AES, BLC, AGC, Day/ Night(Auto)
Image snapshot Yes
Full screen monitoring Yes
Compression format MPEG-4/ JPEG
Video bitrate adjust CBR, VBR
Motion Detection Yes, 3 different areas
Triggered action Mail, FTP, Save to SD card
Pre/ Post alarm Yes, configurable
Security Password protection
Firmware upgrade HTTP mode, can be upgraded remotely
Simultaneous
connection
Up to 10
Audio Yes, 2-way
SD card management
Recording trigger Motion Detection, IP check, Network break
down (wire only)
Video format AVI, JPEG
Video playback Yes
Delete files Yes
Web browsing requirement
OS Windows 2000, XP, 2003, IE 6.0 or above
Hardware Suggested Intel-C 2.0G, RAM_512MB, Graphic
card_64MB
Minimum Intel-C 1.6G, RAM_256MB, Graphic
card_32MB

6/36
III. Product Installation
A. Monitor Setting
i. Right-Click on the desktop. Select “ Properties”
ii. Change color quality to highest (32bit).

7/36
B. Hardware Installation and I/O Pin
Assignment
i. Connect power adaptor
ii. Connect IP Cam to PC or network with Ethernet cable
iii. Set up the network configurations according to the network
environment. For further explanation, please refer to chapter VI,
“Network Configuration for IP CAMERA”.
iv. I/O Pin Assignment: Please refer to following figure.

8/36
C. IP Assignment
i. Use the software, “IP Installer” to assign the IP address of IP CAMERA.
The software is in the attached software CD.
ii. IP installer supports two languages
a. IPInstallerCht.exe_Chinese version
b. IPInstallerEng.exe_English version
iii. There are 3 kinds of IP configuration.
a. Fixed IP (Public IP or Virtual IP)
b. DHCP (Dynamic IP)
c. Dial-up (PPPoE)
iv. Execute IP Installer
v. For Windows XP SP2 user, it may popup the following message box.
Please click “Unblock”.
vi. IP Installer configuration:
vii. IP Installer will search all IP Cameras connected on Lan. The user can
click “Search Device” to search again.
viii. Click one of the IP Camera listed on the left side. The network
configuration of this IP camera will show on the right side. You may
change the “name” of the IP Camera to your preference (eg: Office,
warehouse). Change the parameter and click “Submit” then click “OK”.
It will apply the change and reboot the Device.

9/36
ix. Please make sure the subnet of PC IP address and IP CAM IP address
are the same.
The same Subnet:
IP CAM IP address: 192.168.1.200
PC IP address: 192.168.1.100
Different Subnets:
IP CAM IP address: 192.168.2.200
PC IP address: 192.168.1.100
To Change PC IP address:
Control PanelNetwork ConnectionsLocal Area Connection
PropertiesInternet Protocol (TCP/IP) Properties
Please make sure your IP Camera and PC have the same Subnet. If not,
please change IP Camera subnet or PC IP subnet accordingly.
x. A quick way to access remote monitoring is to left-click the mouse twice
on a selected IP Camera listed on “Device list” of IP Installer. An IE
browser will be opened.
xi. Then, please key in the default “user name: admin” and “password:
admin”.

10/36
D. Install ActiveX control:
For the first time to view the camera video via IE, it will ask you to install the
ActiveX component.
If the installation failed, please check the security setting for the IE browser.
i. IE Tools Internet Options… Security Tab Custom Level…
Security Settings Download unsigned ActiveX controlsSelect
“Enable” or Prompt.
ii. IE Tools Internet Options… Security Tab Custom Level…
Initialize and script ActiveX controls not marked as safe Select
“Enable” or Prompt.
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels HESA Caméra de sécurité