Specifications are subject to change without notice. No liability accepted for errors or omissions. 10
High performance DC UPS s stem
No-Break switching between charger & batter
Batter detection - regular batter presence and
batter circuit integrit checks
Alarm rela outputs
LED flash codes for precise state indication
Deep discharge protection for batteries
ECB for batter overload & short circuit protection
Fused reverse batter polarit protection
Automatic temperature compensated output volts
Option - batter condition test (BCT)
Option - communication interface allows remote
monitoring & user control of BCT function - i ver-
sions
Batteries external to charger - order separatel
ENVIRONMEN AL
Operating
temperature
Storage temperature
Humidity
Cooling
Protection
♦ 24 Month Warranty
Input voltage
Fusing / protection
Isolation
Efficiency
Inrush current
Output power
Output voltage
Voltage adj. range
emp. compensation
Current limit
Line regulation
Load regulation
Noise
Drift
Hold-up time
urn on time
hermal protection
Overvoltage protection
EMI
Safety
Vibration
ELEC RICAL
180 - 264V, 50/60 Hz (standard)
or 88 - 132VAC (internal link selectable)
5A input fuse and varistor
Battery fuse plus ECB for battery circuit
1KV DC input - output / earth
> 85%
Soft start circuit
250W
13.8, 27.6, 34.5, 41.4, 55.2VDC
85 - 105% of Vout
Temperature sensor on 1.7m lead with adhe-
sive pad: -4mV / °C / cell ±10%
PSU: 100% rated current
Battery: 25-100% rated current (factory set)
<0.2% over AC input range
<0.4% open circuit to 100% load
<1% output voltage
0.03% / °C
20 ms without battery (nominal - max. Vin)
< 1 sec
Yes, self-resetting
Over-voltage protection on output
at ~ 130% of nominal output voltage
CISPR 22 / EN55022 class A
IEC950 / EN60950 / AS/NZS3260
Designed to meet MIL-STD-810F Method
514.5
-20 to 50 °C ambient at full load
De-rate linearly at >50 °C to zero @ 70 °C
-30 to 85 °C ambient
0 - 95% relative humidity non-condensing
Natural convection except for 12V model (fan)
IP20
No-Break™ FUNC IONS AND ALARMS
Reverse polarity pro-
tection
Battery monitoring
Battery protection
- low battery volts
- overload
- short circuit
Indication LEDs
Alarms
Alarm relay contacts
Standby mode
Battery condition test
(BC )
Battery reverse connection will open internal
fuse (and produce alarm)
Detects for presence of battery on start up,
then every 60 minutes when charge current <
200mA
Electronic circuit breaker (ECB) operates
under the following conditions:
• battery voltage drops to 1.67V/cell -
auto reset
• < 300ms for load > 6 x rated PSU cur-
rent, allows ~1.5x rated PSU current
from battery without acting,
• < 2ms, backed up by fuse
Green: Battery System OK, Power OK
Red: Standby
• Power OK (alarm on mains fail)
• Battery System OK - alarms when battery
voltage low (on mains fail) , battery
missing, battery circuit wiring faulty, BCT
fail (if enabled)
C - NO - NC full changeover rated 1A /50V
DC, 32VAC
Turns off DC output of PSU & allows load to
run off battery
Optional - if enabled, default setting =
20mins/28days). BCT can be started and
stopped by the user on SR250 i. BCT relay
provided to control an external test load.
incl. S 250i
SPECIFICATIONS All specifications are typical at nominal input, full load and at 20°C unless otherwise stated.