Use 3 bends only
Our flexible flue has the ability to bend
3 times between the heating unit and
the cowl. This includes the bend
straight out of the heater if you’re
fluing through the ceiling or floor.
Make the flue pipe go over
the bearers and joists.
You may bend the flue over joists and bearers.
It is recommended that a 20mm clearance be
maintained between the smaller gas exhaust
flue and combustible materials.
Fluing where the pipe had a spot
lower than the rest.
Never allow a low spot in the flue.
Installing the flue with a dip or “goose
neck” can result in reduced efficiency or
even prevent the fire from working.
Do...
Do...
Never Do...
Using your exible ue pipe
The Seamless’s revolutionary ue system incorporates one
65mm diameter pipe and one 58mm diameter pipe.
Congure triangle
Addition literature
Supplements for ue installation can be obtained by contacting your Heatmaster dealer.
Key Information – Quick step check list
*All information contained in this mini summary is correct at the time of publication. This is only a summary and should be read in conjunction with the full installation
instructions. Pictures are representative only and are not drawn to scale. Installation should be carried out by a licensed gas tter and any electrical work carried out by a
licensed electrician.
Minimum clearances required for balanced ue terminals or the ue terminals of outdoor appliances
(To be installed in accordance with local authority requirements)
a Bellow eaves, balconies or other projections 300 mm
b From the ground or above a balcony 300 mm
c From a return wall or external corner 500 mm
d From a gas meter (M) 1000 mm
e From an electricaity meter or fuse box (P) 500 mm
f From a drain or soil pipe 150 mm
g Horizontal from an building structure 500 mm
h
From any other ue terminal, cowl or combustion air intake
500 mm
j Horizontally from an openable window, door, or non-mechanical
air inlet, or any other opening into a building, with the exception of
sub-oor ventilations 500 mm
k Vertically below an openable widow, door,or non-mechanical
air inlet, or any other opening into a building, with the exception of
sub-oor ventilation 150 mm
l Minimum horizontal clearance to any surface
(such as an exterior wall) for vertical terminations 610 mm
m Minimum height above roof line for vertical termination 600 mm
✘
✔
✔
0m
1m
2m
3m
4m
4m
3m
2m
1m
Example 1
Example 2
Example 3
1
2
3
A 20mm clearance is recommended from the extraction (smaller) ue to combustibles.
NOTE: NOT INTENDED FOR FIREPLACE INSERT
Plumber Incoming gas connection provided – 1/2 inch BSP male connector *please provide approved 1m ex gas
pipe & gas shutoff valve, to allow for removal if required.
Gas input – 36MJ high
18MJ low
Manifold pressure
(Nat gas) 0.88 Kpa
Appliance must be tested for correct operation prior to leaving
If appliance cannot be adjusted to perform correctly contact Heatmaster
Electrician Standard ex 2m, 3 pin plug provided. Requires power point with double pole isolation switch.
Using up to three bends, use this triangle to work
out measurements for your 4.5 mtr ue. The
Seamless can be ued through the roof,
wall or oor. *See your Heatmaster
dealer for full details.