4
1.Do not place Propane/LPsupply tank(s) inside anystructure.Place Propane/LP supply tank(s)outdoors.
2.Thisheater should not be installed ina bedroom or bathroom.
3.Do not use this heater as awood-burning heater. Use only the logs provided with the heater.
4.Do not add extra logs or ornaments such as pine cones,vermiculite, orrock wool. Using these added items
can cause sooting. Do not add lava rock around base. Rock and debris couldfall into the control area of
heater. After servicing, always replace screen before operating heater.
5.Make sure the heater screen is in place before running the heater.
6.Thisheater is designed to be smokeless. If logs everappear to smoke, turn offheaterand callaqualified
serviceperson. Note: During initial operation,slight smoking could occur due to log curing and the heater
burning manufacturing residues.
7.To prevent the creation ofsoot,follow the instructions in Cleaningand Maintenance (page 19).
8.Before using furniturepolish,wax, carpet cleaner,or similar products, turn heater off. Ifheated,the vapors
fromthese products maycreate a white powderresidue within burner box or on adjacent wallsor furniture.
9.Thisheater needs fresh air ventilation to run properly. This heaterhas an Oxygen Depletion Sensing (ODS)
safetyshutoff system.The ODSshuts down the heater if not enough fresh air is available.See Airfor
Combustion and Ventilation,pages 7 through 9.If heater keeps shutting off, see Troubleshooting, pages20
through 22.
10. Do not run heater:
lWhereflammable liquids orvapors are used orstored.
lUnder dusty conditions.
11. Do not use this heater to cook food or burn paper or otherobjects.
12. Do not use this heater if any parthas been underwater.Immediately calla qualified service technician to
inspect the room heaterand replace anypart of the control system and any gascontrol which has been
underwater.
13. Turnoff and unplug heater and let coolbefore servicing. Only a qualifiedservice person should service and
repair heater.
14. Operating heater above elevations of 4,500 feetcould cause pilotoutage.
15. Do not operate heater if any log is broken. Do notoperate heater if any log is chipped (dime-sized or larger).
16. To prevent performance problems,do notuse a propane/LP fuel tank of less than 100 lbs capacity.
QUALIFIED INSTALLING AGENCY
Installation and replacement ofgas piping, gas utilization equipment oraccessories and repair and
servicing of equipment shall be performed only by a qualified agency.The term “qualified agency”means
any individual, firm, corporation,or company that either in person or through a representative is engaged
in and is responsible for:
a) installing, testing, or replacing gaspiping or
b) Connection, installing,testing, repairing, or servicing equipment; thatis experienced in such work;that is
familiar with all precautions required; and thathas complied with all the requirement ofthe authority
having jurisdiction.