023-00354-Rev1.4 evc/epc User Manual Copyright © High Country Tek, Inc. – 2013 1
evc/epcController
WithSAEJ1939Interface
High Country Tek, Inc. reserves the right to improve this product at any time and without notice. This manual
may contain mistakes and printing errors. The information in this publication is regularly checked and
corrections made in the next issue. Please check our website or contact our customer support for latest version.
HCT accepts NO liability for technical mistakes or printing errors or their consequence
evc/epc
Electronic Valve Controller
User Guide

023-00354-Rev1.4 evc/epc User Manual Copyright © High Country Tek, Inc. – 2013 2
evc/epcController
WithSAEJ1939Interface
High Country Tek, Inc. (HCT) is North America’s foremost independent designer and producer of
modular, ruggedized digital and analog electronic controller products for the fluid power industry.
From our factory in California, we build, test and produce ‘specialty’ controllers for specific functions as
well as our ‘DVC family’ of fully adaptable user programmable units that can be integrated to enable large
area networked system solutions.
The modules are used in mobile, industrial and marine applications. They are also applied successfully in
other industry segments.
HCT’s every module is encapsulated in solid flame resistant material for maximum durability, electrical
integrity and complete environmental security. We deliberately select the highest quality components at
all times, ensuring 100% operating products.
HCT is a market leader in many application arenas, including hydraulic generator, e-Fan and hydraulic
fan system controls. These controllers realize significant fuel, emission and operational savings by
optimizing the applications.
HCT’s market neutrality offers dependable integration with any hydraulic OEM products for easy, simple
and accurate control of valves, pumps, sub-systems or systems.
Our best-in-class customer service and product reliability is well known and trusted throughout the fluid
power network and we look forward to working with you in the future.
For our latest information, products, updates, guides and accessories, please visit us at:
www.hctcontrols.com
The information in this publication is intended as a guide only, and High Country Tek, Inc. (HCT) takes
NO responsibility for usage and implementation in any user entered values into the provided GUI
structure.
HCT strongly suggests that the user attends one of the product training courses to ensure correct and full
understanding of this information and to learn further optimized methods of control techniques.
Please contact HCT customer service to book one of the scheduled training dates or discuss arranging a
course specific to your company needs.

023-00354-Rev1.4 evc/epc User Manual Copyright © High Country Tek, Inc. – 2013 3
evc/epcController
WithSAEJ1939Interface
Contents
Welcome .........................................................................................................................................................4
Warranty Information.......................................................................................................................................4
Product Application Guidelines .......................................................................................................................5
Software Safety...............................................................................................................................................5
Controller Specification ...................................................................................................................................6
Controller Mounting Information......................................................................................................................6
Controller Input vs Output ...............................................................................................................................7
Using the evc/epc with your PC ......................................................................................................................8
evc/epc GUI ..................................................................................................................................................10
File ........................................................................................................................................................10
Default Settings.....................................................................................................................................11
Environment ..........................................................................................................................................11
Password ..............................................................................................................................................11
Help.......................................................................................................................................................12
Exit ........................................................................................................................................................12
Dashboard, Status and Graphing Windows..........................................................................................12
Data Logging.................................................................................................................................................13
Dashboard.....................................................................................................................................................15
Output A or B Coil Settings ...........................................................................................................................16
Manual Mode ................................................................................................................................................19
Command & Error Settings ...........................................................................................................................20
Pulse Input Settings ......................................................................................................................................23
Global Settings..............................................................................................................................................24
Factory Settings ............................................................................................................................................25
SAE J1939 ....................................................................................................................................................26
Operational Modes........................................................................................................................................27
Hydraulic Valve or Pump Control..........................................................................................................27
Anti-Stall or Horsepower Management With Fixed Command .............................................................28
Anti-Stall or Horsepower Management With Variable Command.........................................................30
Dual Output With Over Speed Protection .............................................................................................31
Constant Flow Mode .............................................................................................................................32
Electrical Diagram .........................................................................................................................................33
LED flash / Diagnostic Codes .......................................................................................................................34
Module Status LED ...............................................................................................................................34
Communication Status LED..................................................................................................................34
SAE J1939 CAN Bus ....................................................................................................................................35
Command Message Format .................................................................................................................35
Status Message Format........................................................................................................................36
Analog Values Message .......................................................................................................................37
Parameter Values .................................................................................................................................37
Problems Installing the Com Port Adapters..................................................................................................39

023-00354-Rev1.4 evc/epc User Manual Copyright © High Country Tek, Inc. – 2013 4
evc/epcController
WithSAEJ1939Interface
Welcome
Welcome to the High Country Tek Inc. (HCT) evc/epc user manual.
If you have any questions, requesting new features or finding errors, please contact us @ 530-265-3236
or e-mail at info@hctcontrols.com, giving details of the issues and your contact information.
Introduction
This manual explains the installation and use of the evc/epc Digital Controllers. Users need to understand
the hazards in an electromechanical environment. Read this entire manual before installation. Pay particular
attention to caution and safety information.
Cautions
Changing setup values or operating modes while the machine is running may cause unintended machine
movement. It may lead to possible injury or death. Any moving parts should be disabled prior to
changing setup values or operating modes. In any case, exercise caution and work should be completed
only by qualified personnel.
Warranty Information
High Country Tek guarantees this product to be free of defects in materials and workmanship for one year
from the date shipped from the factory. Within this time frame, High Country Tek will provide evaluation of
warranted items free of charge. Warranty repair or replacement will be at the factory’s discretion.
Please have the units full Model / Part Number and Serial Number available when contacting the factory.
Do not return products to the factory without a RMA (Return Material Authorization) number.
Controller Updates
HCT continuously improves the controllers and makes additional information and/or features available.
Please check on-line at www.hctcontrols.com for the latest products, software update and information.

023-00354-Rev1.4 evc/epc User Manual Copyright © High Country Tek, Inc. – 2013 5
evc/epcController
WithSAEJ1939Interface
Product Application Guidelines
ALWAYS do the following
FULLY read this manual and accompanying data sheets BEFORE starting.
Isolate this unit from all other equipment BEFORE any form of welding.
Isolate the controller from ANY form of battery charging or battery boosting.
Be aware of the adjustments and reactions on the external equipment.
Operate the units within the temperature range.
Use the correct tools to do the job (i.e. P.C., software) etc.
Separate High Voltage AC cables from Low Voltage DC signal and supply cables.
Check that the units supply voltage is CORRECT, ‘ELECTRICALLY CLEAN’ and STABLE.
Make sure the controller output voltage & current is compatible with the equipment!
All unused wires / terminals should be terminated safely.
Ensure ALL connectors have no unintended SHORT or OPEN circuits.
Ensure ALL connectors are wired correctly, secure, locked in place and fully connected.
Observe all the set-up procedures in this manual.
Follow and abide by local and country health & safety standards!
NEVER do the following
Arc Weld or Charge Batteries with this module connected as damage can/will occur.
Attempt to use this unit if you are unsure of electrical OR mechanical connections or expected operation.
Use a power supply that is not rated for the output current under full load.
Allow wires to or from the unit to short circuit (to each other or chassis/cabinet etc.).
Use this controller in areas of intense Radio Frequency fields without adequate screening.
Disconnect or connect wires to or from this unit unless it isolated from the power supply.
Use this unit in temperatures that exceed the limits.
Start or operate this controller without ensuring ALL work areas are clear of personnel!
Software Safety
The GUI and controller software give the user flexibility and ease of use, even for novice users.
The GUI is not intended to be connected to a non-evc/epc unit. Care must be taken to use the correct GUI
and hardware combination. After program entries, cycle the power to ensure changes are accepted by the
unit.
When the GUI is first connected to a powered controller, a ‘Handshake’ takes place that confirms the
internal software (BIOS) is compatible with the GUI software. Only then the PC and the module are allowed
to communicate and exchange data.
If an error or miss-match is detected, or loss of communication, the GUI software will indicate “OFF LINE”
and NOT allow communications until the problem is corrected.

023-00354-Rev1.4 evc/epc User Manual Copyright © High Country Tek, Inc. – 2013 6
evc/epcController
WithSAEJ1939Interface
Controller Specification
Controller Mounting Information
1. Mountcontrollerinaneasilyaccessiblelocation.
2. Mountcontrollertoaflat,coolsurface.
3. Ifmountingtoahydraulicproduct,allowatleasta2mmairgapunderneaththeunit.
4. UseBOTHmountingholeswithcorrecthardware.
5. DONOTmountcontrollerwithconnectorfacingUPifpossible.
Housing Type HCT unique encapsulated block
Power Supply Voltage 9 to 32Vdc (Absolute Maximum)
Current Consumption Valve current + 50mA Quiescent (Max)
Command Inputs SAE J1939
2x switches (ON/Off)
1x analog input (0-5V,0-10V, 4-20mA)
1x analog input
(0-5V,0-10V, Pulse or Freq - 3 to 30KHz)
Input Impedance Voltage inputs = 100k
4-20mA input = 100
Outputs 2x 3A proportional PWM
(short circuit protection and open circuit alert)
1x 5Vdc ±10% regulated voltage (max 250mA)
PWM Dither Freq Software adjustable - 33 to 500Hz
Module Connector DTF15-12PB, 12-way Male
Communication Mini-B USB standard
Housing Material Black, Polycarbonate
Encapsulation Flameproof epoxy resin
Mounting 2x No.8 (5mm) screws
Temperature Range -40 to +85ºC (operational)
NEMA/IP Rating NEMA 6P/IP67
45mm
125mm
60mm
‐Prop.O/P1ON
‐Prop.O/P2ON
‐PulseI/PActive
‐Digi.I/P1Active
_Module
Status
_Comm.
Status
‐Digi.I/P2Active
www.hctcontrols.com
SN:
evc
Electronic Valve
Controller
MadeinUSA
43
9101112
21
65
78
Use2xM5(#8)screwsorbolts

023-00354-Rev1.4 evc/epc User Manual Copyright © High Country Tek, Inc. – 2013 7
evc/epcController
WithSAEJ1939Interface
Controller Input vs Output
NOTE:
Alltestsconductedat70Fambient,24Vdcsupplywith8coilandIminsettozeroandImaxsetto1A.
4-20mA Input:
Imin = 0.05A, Imax = 1A
The internal current shunt resistor is 100.
0 to +5V Input:
Imin = 0, Imax = 1A
The input impedance is 100K.
0 to +10V Input:
Imin = 0, Imax = 1A
The input impedance is 100K.

023-00354-Rev1.4 evc/epc User Manual Copyright © High Country Tek, Inc. – 2013 8
evc/epcController
WithSAEJ1939Interface
Using the evc/epc with your PC
Install the Graphical User Interface (GUI) in a host PC. Use the default file locations for easy future
update. The user has the option to choose where the program should be located.
Don’t run the GUI from a network as it needs access to certain files only in the Windows directories.
System Requirements
Windows XP, Vista or Windows7, 100MB or greater free disk space.
Insert the CD into the PC drive and follow the on-screen instructions. This will install the evc/epc GUI,
manual and help files.
Install the Com Port drivers for the evc/epc.
Start HCT Products Digital Controllers evc/epc USB Serial Drivers, CDMxxxxx_setup.exe
To insure a complete install, run the CDMxxxxx twice.
The evc/epc can be powered by +5V USB to allow configuration without connecting to a 12/24Vdc system.
A message “Supply Voltage is Low” appears on the screen. You may fully communicate, change, and
save settings to the unit. You can not drive the coil(s).

023-00354-Rev1.4 evc/epc User Manual Copyright © High Country Tek, Inc. – 2013 9
evc/epcController
WithSAEJ1939Interface
At start up the GUI searches the PC com ports for the evc/epc controller.
The default MAC ID is 1. If the evc/epc has been programmed with a different Mac ID, you can search
for the controller by “Find Module” or enter the Mac ID. The “Find Module” will restart the operation when
the unit responds with its information and Mac ID.
The MAC ID determines the module’s Command and Status PGN addresses on the SAE J1939 bus. The
user may command many evc/epc modules on a single J1939 bus. Please see SAE J1939 section.

023-00354-Rev1.4 evc/epc User Manual Copyright © High Country Tek, Inc. – 2013 10
evc/epcController
WithSAEJ1939Interface
evc/epc GUI
File
All changes made through the GUI are temporary until saved permanently.
Permanently save settings to unit: Save the settings from the RAM (temporary) memory to the unit’s
EEPROM (permanent memory).
Permanently save settings to unit & file (.dat): Permanently save the settings to the unit’s EEPROM
and to a data file that may be loaded later.
Settings will be lost if not permanently saved before power cycle.
Reset the unit with a power cycle, you must remove both the USB cable and DC power from the
unit.
Restore unit to last permanent settings saved: Reload RAM with settings stored in the EEPROM. This
will undo all changes made since the last Permanent Save.
Restore unit settings from data file (.dat): Load the data file from the PC to the evc/epc for different
modes of operation.
Restore unit from v1.03 data file: Load the previous version data file from the PC to the evc/epc for
different modes of operation.
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels HCT Contrôleurs