GST C-9105R Manuel utilisateur

HTTP://WWW.HOMBI.RU
C-9105R
Conventional Reflective Beam Detector
Installation and Operation Manual The Intelligent Solution
CONTENTS
IOverview.................................................................................1
II Features..................................................................................1
III Technical Specification..........................................................2
IV Structure and Operation Principle........................................4
VMounting and Wiring..............................................................6
1Ambient Conditions for Installation .......................................6
2Mounting Height and Position...............................................7
3Mounting.............................................................................10
4Wiring .................................................................................14
VI Commission..........................................................................15
VII Cautions............................................................................17
VIII Operation...........................................................................18
1Reading Information...........................................................18
2Setting Sensitivity Level......................................................18
3Setting Device Type............................................................19
4Other Functions..................................................................19
IX Troubleshooting...................................................................20
XMaintenance .........................................................................21
XI Accessories..........................................................................22
Appendix 1 Warnings..................................................................23
Appendix 2 Warranty...................................................................25
HTTP://GSTRU.RUE-MAIL: [email protected]

HTTP://WWW.HOMBI.RU
C-9105R
Conventional Reflective Beam Detector
Installation and Operation Manual The Intelligent Solution
1
I Overview
C-9105R Conventional Reflective Beam Detector (hereinafter called
the detector) is a non-addressable reflective infrared beam smoke
detector, which must be used together with a reflector. The number
of reflector(s) to be used (one or four) depends on the distance from
the detector.
With excellent built-in microprocessor, the detector has strong ability
of analysis and judgment. The detector can automatically carry out
system adjustment, compensation of variation of ambient data, and
judgment of fire and fault through fixed algorithm, and indicate these
states by LED and signal output terminals. With new and reasonable
design, attractive appearance, flexible adjustment and alignment
method it’s easy to install and adjust. The sensitivity of the detector
can be set through hand held programmer in field, decreasing the
demand for cleanliness of field conditions, and enlarging application
areas. The detector is applicable to historical buildings, warehouses,
large storages, shopping malls, leisure centers, exhibition halls,
hotel lobbies, printing houses, clothing factories, museums and
prisons etc, as well as places where slight smoke particles exist.
II Features
(1) Wide operating voltage range, big monitoring areas.
(2) Combination of the emitting and receiving part makes mounting
easy and optical pathway accurate.
(3) Built-in microprocessor enables intelligent judgment of fire
alarm and fault.
(4) The detector can calibrate automatically, which ensures that
one person complete adjustment in short time. It’s also
HTTP://GSTRU.RUE-MAIL: [email protected]

HTTP://WWW.HOMBI.RU
C-9105R
Conventional Reflective Beam Detector
Installation and Operation Manual The Intelligent Solution
2
convenient to operate.
(5) Self-diagnosis function can monitor the inner fault.
(6) Automatic compensation for factors weakening received signals,
such as dust contamination, positional excursion and ageing
transmitter.
(7) It has volt-free output contacts for fire alarm and fault.
(8) Two sensitivity levels can be set in field.
(9) The detector’s optical pathway is designed with strong
anti-interference ability.
(10) SMT processing technology.
(11) Attractive and decent appearance.
III Technical Specification
(1) Power Voltage: 15VDC~28VDC
(2) Power Current: Commission current≤20mA
Standby current≤12mA
Alarm current≤22mA
(3) Fire Alarm and Fault Contact Output:
Fire Alarm Relay: Contact capacity 28V/2A, which is normally
open in normal state and closed in fire alarm state.
Fault Relay: Contact capacity 28V/2A, which is normally closed
in normal state and open in fault state.
(4) Angle of Adjusting: -6°~+6°
(5) Maximum angular misalignment: ±0.5°
(6) Sensitivity Level:
Level 1: High sensitivity.
Level 2: Low sensitivity.
(7) Indication of Detector State:
Commission: Green LED and Yellow LED are lit or flash in a
HTTP://GSTRU.RUE-MAIL: [email protected]

HTTP://WWW.HOMBI.RU
C-9105R
Conventional Reflective Beam Detector
Installation and Operation Manual The Intelligent Solution
3
certain way. Refer to details in Section VI Commission.
Normal monitoring state: Red LED flashes periodically.
Fire: Red LED constantly illuminates,. Fire alarm should be
cleared through powering up again.
Fault: Yellow LED constantly illuminates. The detector clears
the fault signal automatically if the condition causing the fault
disappears.
Optical pathway obscured totally: the detector first gives fault
signal and turns on Yellow LED. 20s later, it alarms fire,
illuminates Red LED and turns off Yellow LED. Note: In this
case, it does not mean there is a fire. After the obscuration
is removed, the detector clears fault signal automatically.
Fire signal has to be cleared by powering up the detector
again.
(8) Operating Environment:
Temperature: -10°C~+50°C
Relative Humidity≤95%, non condensing
(9) Monitoring Area: Maximum monitoring area: 14×100=1400m2
Maximum width: 14m
(10) Length of Optical Pathway: 8m~100m
(11) Protection Level:
Under common environment, ingress protection rating is IP20.
Under special environment, ingress protection rating is IP66
through glue-seal treatment.
(12) Dimension: length: 206mm width: 95mm thickness: 95mm
(13) Material and Color of Enclosure: ABS, gray
(14) Weight: 450g
(15) Mounting Hole Spacing:
HTTP://GSTRU.RUE-MAIL: [email protected]

HTTP://WWW.HOMBI.RU
C-9105R
Conventional Reflective Beam Detector
Installation and Operation Manual The Intelligent Solution
4
Spacing for embedding: 158mm
Spacing for surface mounting: 79mm×96mm
IV Structure and Operation Principle
(1) Appearance of the detector is shown in Fig. 1.
Fig. 1
(2) Internal devices of the detector and positions to be glued are
shown in Fig. 2.
Fig. 2 To Be Glued
To Be GluedMounting Direction
Adjusting Wheel
Rotary Rack
Flexible Cable
Cable Entry
Knock-off
H
Commission Zone
Reed Switch
Receiving
Window
Emitting
Window
LEDs
HTTP://GSTRU.RUE-MAIL: [email protected]

HTTP://WWW.HOMBI.RU
C-9105R
Conventional Reflective Beam Detector
Installation and Operation Manual The Intelligent Solution
5
(3) Operation Principle
The detector and reflector are placed oppositely. The detector
includes emitting part and receiving part. Infrared beam of certain
intensity sent out from the emitting part is reflected by the right-angle
prisms of the reflector, and then received by the receiving part of the
detector. The receiving part simultaneously collects and amplifies the
returned infrared beam, analyzes and judges the collected signals
through its microprocessor. When the detector is in normal
monitoring state, the intensity of infrared beam received by the
receiving part is steady at a certain level. When smoke particles
enter the detecting area, the intensity of infrared light received by the
receiving part falls owing to light scattering. When the smoke
particles reach a certain density, and the intensity of infrared light
received by the receiving part is reduced below the preset threshold
value, the detector alarms fire, illuminates Red LED, and closes
volt-free fire output contact. Operation principle is shown in Fig. 3.
00m
Smoke
Reflector
Mounting
Bracket
Infrared
Beam
Detector
Fig. 3
HTTP://GSTRU.RUE-MAIL: [email protected]

HTTP://WWW.HOMBI.RU
C-9105R
Conventional Reflective Beam Detector
Installation and Operation Manual The Intelligent Solution
6
V Mounting and Wiring
1 Ambient Conditions for Installation
The detector works on light obscuration principle. Avoid any
fixed or moving obscuration in its optical pathway when
installing.
The wall for mounting either the detector or the reflector should
be firm and smooth. The detector is mounted vertical to the wall.
The wall may seem to be smooth, but corrugated or uneven, or
may be changed by the environment (in rainy season or in
winter) and the installer should ensure the detector not affected
by these factors. If the detector is installed on sustaining rack
similar to metal tube, make sure the sustaining rack fixed firmly.
Not Fit for Locations where:
¾Space height is over 40m.
¾It is not roofed.
¾Space height is less than1.5m.
¾There are a lot of dust, powder or vapor.
¾It is clean normally, but can be dusty insome special cases.
¾Where temperature is high. Note: Temperature at top
part of a workshop with transparent roof may be over
50℃when there is sunshine.
¾There is no access to maintenance.
¾The mounting wall or fitting is greatly affected by
mechanical vibration.
¾There are fixed or moving objects within 1m from the
detector’s optical pathway.
HTTP://GSTRU.RUE-MAIL: [email protected]

HTTP://WWW.HOMBI.RU
C-9105R
Conventional Reflective Beam Detector
Installation and Operation Manual The Intelligent Solution
7
¾There is strong magnetic field.
2 Mounting Height and Position
The mounting height of the detector and reflector should be most
accessible by smoke into beam zone. The following
recommendations are for reference.
a) When space height is not over 5m, the detector and
reflector should be mounted on the two facing walls 0.5m
from the ceiling, as shown in Fig. 4.
Reflector
Detector
5m
4.5m
Fig. 4
b) When space height is between 5m and 8m, the detector
and reflector should be mounted on the two facing walls
0.5m to 1m from the ceiling, refer to Fig. 5.
HTTP://GSTRU.RUE-MAIL: [email protected]

HTTP://WWW.HOMBI.RU
C-9105R
Conventional Reflective Beam Detector
Installation and Operation Manual The Intelligent Solution
8
Detector
Reflector
7m
6m
Fig. 5
c) When space height is more than 8m, the roof is normally
gabled without ceiling, the detector and reflector should be
mounted on the two facing walls about 8m from the floor,
ensuring that the vertical distance between the
detector/reflector and top of the building is more than 0.5m,
refer to Fig. 6. The distance should be 7m from the detector
to the floor.
HTTP://GSTRU.RUE-MAIL: [email protected]
Table des matières
Autres manuels GST Capteur de sécurité

GST
GST DC-9105E Manuel utilisateur

GST
GST DC-M9103 Manuel utilisateur

GST
GST D-9107RExd Manuel utilisateur

GST
GST I-9602LW Manuel utilisateur

GST
GST DI-9104Exd Manuel utilisateur

GST
GST C-9103 Manuel utilisateur

GST
GST DC-9103 Manuel utilisateur

GST
GST DI-9103 Manuel utilisateur

GST
GST I-9406 Manuel utilisateur

GST
GST C-9103 Manuel utilisateur

GST
GST DI-9103E Manuel utilisateur

GST
GST DI-9104Exd Manuel utilisateur

GST
GST DC-9103E Manuel utilisateur

GST
GST DC-9101(Ex) Manuel utilisateur

GST
GST GST-AS-200 Manuel utilisateur

GST
GST DI-9103 Manuel utilisateur

GST
GST DC-M9103 Manuel utilisateur

GST
GST I-9101 Manuel utilisateur

GST
GST DC-9103E Manuel utilisateur

GST
GST DC-9103 Manuel utilisateur