GEM M2-1F Manuel utilisateur

Technical features:
• red display of -19999…99999 digits (optional: green, orange or blue display)
• minimal installation depth: 70 mm without plug-in terminal
•min-/maxmemory
• adjustment via factory default or directly on the sensor signal
• 30 adjustable setpoints
• display flashing at threshold undercut or exceedance
• Schmitt-trigger-input
• zero-key for triggering of HOLD, TARA…
• permanent min-/max-value recording
• digital frequency filter for contact bounce suppression and interference suppresion
• frequency filter with varying pulse-duty factor
• volume metering (totaliser) for frequencies up to 1 kHz (accurate to a pulse)
• mathematical function like reciprocal value, square root, rounding
• sliding averaging with an optional dynamic display filter
• setpoint generator
• brightness control
• programming interlock via access code
• protection class IP65 at the front
• plug-in terminal
• sensor supply
• galv. insulated digital input
• option: relay outputs
• option: analog output
• accessories: PC-based configuration-kit PM-TOOL incl. CD & USB.adapter for devices without keypad and
for a simple adjustment of standard devices
User manual M2-1F
Frequency input: 0,01 Hz to 999,99 kHz
Connection for Namur-, NPN-, PNP- and TTL-signals
96x48
M2_1FGB.pdf updated: 04.05.2012

Identification
M2-1FR5B.0307.570BD
M2-1FR5B.0007.670BD
Frequency
Housing size: 96x48 mm
ORDER NUMBERSTANDARD-TYPES
Please state physical unit by order, e.g. m/min.
Options – breakdown of order code:
M2-1 FR 5B.0007.672BD
Basic type M2 Dimension
D physical unit
Installation depth
89 mm, incl.plug-in terminal 2 Version
BB
Housing size
B96xH48xT70 mm 1 Setpoints
0 no setpoints
Type of display 2 2 relay outputs
Frequency F
Protection class
Display colour 1 without keypad,
Blue B operation on the back
Green G 7 IP65 / plug-in terminal
Red R
Yellow Y Voltage supply
4115VAC
Number of digits 5230VAC
5-di
g
it 5 6 10-30 VDC
g
alv.insulated
Digit height Measuring input
14 mm B1 0.01 Hz to 999.99 kHz
Digital input Analog output
without 0 0 without
one I X 0-10 VDC, 0/4-20 mA
Sensor supply
0 without
210VDC/20mA
incl. digital input
324VDC/50mA
incl. digital input
K24VDC/50mA
incl. digital input and
pulse out put (10 kHz only
with frequency measuring)

Contents
1
1. Brief descirption 2
2. Assembly 3
3. Electrical connection 4
4. Function description and operation 6
4.1. Programming software PM-TOOL 7
5. Setting up the device 8
5.1. Switching on 8
5.2. Standard parameterisation (flat operation level) 8
Value assignment for the triggering of the signal input
5.3. Programming interlock „RUN“ 12
Activation/Deactivation of the programming interlock or change into professional
or flat operation level
5.4. Extended parametersation (professional operation level) 13
5.4.1. Signal input parameters „INP“13
Value assignment for the triggering of the signal input incl. linearisation
5.4.2. General device parameters „FCT“17
Superior device functions like Hold, Tara, min/max permanent, setpoint value function /
nominal value function, averaging, brightness control, as well as the control of the digital input and
keyboard layout
5.4.3. Safety parameters „COD“21
Assignment of user and master code to lock or to receive access to defined parameter such as
analog output and alarms, etc.
5.4.4. Analog output parameters „Out“22
Analog output functions
5.4.5. Relay functions „rel“24
Parameter for setpoint definition
5.4.6. Alarm parameters „AL1…AL4“26
Actuator and dependencies of the alarms
5.4.7. Totaliser (Volume metering) „tot“28
Parameter for calculation of the sum function
6. Reset to factory settings 29
Reset parameters onto the delivery state
7. Alarms / Relays 30
Functional principle of the switching outputs
8. Programmer examples 31
Sample applications such as e.g. calculation of the input frequency or the adjustment at unknown rotation speed
9. Technical data 33
10. Safety advices 35
11. Error elimination 36

1. Brief description
2
1. Brief description
The panel meter instrument M2-1F is a 5-digit device for pulse signals, respectivley 2- and 3-wire
sensors. The configuration happens via four keys at the front. The integrated programming interlock
prevents unrequested changes of parameters and can be unlocked again with an individual code.
Optional the following functions are available: a supply for the sensor, a digital input for triggering of
Hold (Tara), one analog output or switching outputs for further evaluating in the unit.
The electrical connection is done via plug-in terminals on the back side.
Selectable functions like e.g. the recall of the min/max-value, an averaging of the measuring signals,
a nominal presetting or setpoint presetting, digital frequency filter for contact bounce suppression
and disturbance suppression with adjustable key relation, a direct threshold value regulation during
operation mode and further measuring setpoints for linearisation, complete the modern device
concept.

2. Assembly
3
2. Assembly
Please read the Safety advice on page 35 before installation and keep this user manual
for future reference.
Sealing
48,0
3,0
Installationdepthincl.plug-intermnal
M2
Gap for physical unit
89,0
1. After removing the fixing elements, insert the device.
2. Check the seal to make sure it fits securely.
3. Click the fixing elements back into place and tighten the clamping screws by hand.
Then use a screwdriver to tighten them another half a turn.
CAUTION! The torque should not exceed 0.1 Nm!
The dimension symbols can be exchanged before installation via a channel on the side!

3. Electrical connection
4
3. Electrical connection
Attention!
For devices with sensor supply, terminal clamps 4 and 8, aswell as 3 and 7 are connected galvanically in the
device.

5
3. Electrical connection
M3-devices
Below you find some connection examples with practical applications:

4. Function- and operation description
6
4. Function- and operation description
Operation
The operation is divided into three different levels.
Menu level (delivery status)
This level is for the standard settings of the device. Only menu items which are sufficent to set the
device into operation are displayed. To get into the professional level, run through the menu level
and parameterise “prof“ under menu item RUN.
Menu group level (complete function volume)
Suited for complex applications as e.g. linkage of alarms, setpoint treatment, totaliser function etc. In
this level function groups which allow an extended parameterisation of the standard settings are
availabe. To leave the menu group level, run through this level and parameterise „uloc„ under menu
item RUN.
Parameterisation level:
Parameter deposited in the menu item can here be parameterised. Functions, that can be changed
or adjusted, are always signalised by a flashing of the display. Settings that are made in the
parameterisation level are confirmed with [P] and thus safed. By pressing the „zero-key“ it leads to
a break-off of the value input and to a change into the menu level. All adjustments are safed
automatically by the device and changes into operating mode, if no further key operation is done
within the next 10 seconds.
Keys for up and down navigation in the menu group level.
Change to menu level.
Change into menu level or break-off in value input.
Parameterisation
level Adjustment of the value / the setting.
Keys for up and down navigation in the menu level.
DescriptionKey
Change into operation mode or back into menu level.
To confirm the changes made at the parameterization level.
Change into operation mode.
Change to parameterisation level and deposited values.
Menu group level
Menu level
Level

7
4. Function and operation description
Function chart:
4.1. Parameterisation software PM-TOOL:
Part of the PM-TOOL are the software on CD and an USB-cable with device adapter. The
connection is done via a 4-pole micromatch-plug on the back side of the device, to the PC-side the
connection ist done via an USB plug.
System requirements: PC incl. USB interface
Software: Windows XP, Windows VISTA
With this tool the device configuration can be generated, omitted and safed on the PC. The
parameters can be changed via the easy to handle program surface, whereat the operating mode
and the possible selection options can be preset by the program.

8
Setting end value of the measuring range, END:
Default: 100e3
Choose between six different frequency ranges. Confirm the selection with [P] and the display
switches back to menu level.
Setting the final value of the measuring range, END:
Default: 10000
Set the final value from the smallest to the highest digit with [▲] [▼] and confirm each digit with
[P]. A minus sign can only be parametrized on the highest value digit. After the last digit, the
display switches back to the menu level. If Sens was selected as input option, you can only
select between noca and cal.With noca, only the previously set display value is taken over, and
with cal, the device takes over both the display value and the analogue input value.
Selection of the input signal, TYPE:
Default: frequ
If the scaling of the device is done via SEnS.F (Sensor calibration), the frequency range needs to
be preset under rAnGE and is adjusted by application of the final value /initial value. If FrEqU
(Factory calibration) is preferred, the final value needs to be entered under End and the final
frequency needs to be entered under EndA. Under OFFS the initial value needs to be entered and
under OFFSA the initial frequency. There is no application of the measuring signal. Confirm the
selection with [P] and the display switches back to menu level.
Parameterisation levelMenu level
5.1. Switching-on
Once the installation is complete, you can start the device by applying the voltage supply. Before,
check once again that all electrical connections are correct.
Starting sequence
For 1 second during the switching-on process, the segment test (8 8 8 8 8) is displayed, followed by
an indication of the software type and, after that, also for 1 second, the software version. After the
starting sequence, the device switches to operation/display mode.
5. Setting up the device
5.2. Standard parameterisation: (flat operation level)
To parameterize the display, press the [P] key in operating mode for 1 second. The display then
changes to the menu level with the first menu item TYPE.
5. Setting up the device
9.9999 Hz 99.999 Hz 999.99 Hz 9.9999 kHz
99.999 kHz 999.99 kHz
Table des matières
Autres manuels GEM Instrument de mesure

GEM
GEM 1230 Instructions de montage

GEM
GEM 1231 Manuel utilisateur

GEM
GEM 840 Instructions de montage

GEM
GEM Hemochron 100 Manuel utilisateur

GEM
GEM 1205 Manuel utilisateur

GEM
GEM 1205 Manuel utilisateur

GEM
GEM 1240 Manuel utilisateur

GEM
GEM 514 SKS Manuel utilisateur

GEM
GEM 3030 mFlow Manuel utilisateur

GEM
GEM 566 Manuel utilisateur
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur