GEM AD500 Manuel utilisateur

AD500
Instruction Manual
Automatic Door Operator

Table of Contents
General Safety Precautions -------------------------------------------
Declaration by Manufacturer -------------------------------------------
Introduction ---------------------------------------------------------------
Product Features --------------------------------------------------------
Part Identification --------------------------------------------------------
Specifications -------------------------------------------------------------
How the AD500 Works --------------------------------------------------
Pre-Installation -----------------------------------------------------------
Template Instructions ---------------------------------------------------
Installation (Video Instructions) ---------------------------------------
Trouble Shooting ---------------------------------------------------------
Maintenance ---------------------------------------------------------------
Safety Instructions for Users -------------------------------------------
01
01
02
02
02
03
04
09
11
12
12
13
15

This instruction manual is intended solely for qualified professionals. All installations, electrical connections and
adjustments must follow the installation instructions.
Please read these instructions carefully and watch video instructions before installing this unit. Incorrect
installation may result in severe personal injury and/or damage to property.
Packaging materials (plastic and polystyrene, etc) should be discarded without causing environmental
damage and should be kept out of reach of children.
Do not install this unit in a chemical explosive environment or atmosphere.
Make sure the existing structure is up to standard. GEM is not responsible for any damage resulting from
incorrect use of this unit.
The safety devices (e.g. photocell and emergency stop) must follow the technical safety regulations and
current safety standards, including the limit of forces and speeds.The safety devices must protect any areas
where the risk exists of being crushed, cut or gragged, or where there are any other risks generated by the
motorized door/gate. Apply hazard area notices required by applicable regulations.
Each installation must clearly show the identification details of the motorized door/gate.
Make sure the voltage specified is correct for the device.
Must provide at least 10 seconds of rest time between every new cycle to ensure adequate residual current will
return to power system.
When necessary, connect the motorized door/gate to a reliable earth system with applicable safety
regulations. During installation, maintenance and repair, interrupt the power supply before opening the lid to
access the electrical parts. To handle electronic parts, wear earthed antistatic conductive gloves.
1
Automatic Door Operator
Manual
General Safety Precautions
Declaration by Manufacturer
Gianni Industries, Inc.
Address: No. 13, Zhongxing Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
E-mail: [email protected]
Website: www.gianni.com.tw
Herewith declares that AD500 Automatic Door Operator for swing doors: (One way direction only)
AD500 Automatic Door Operator can not be installed with other mechanism except electric door locks.
UL listed and in conformity with other CE directives: Electromagnetic Compatibility Directive (EN61000) and Low
Voltage Directive (EN 60950-1)
Product life: 3 years (Factory test: 1 million times)
Product should be operated under the recommended door weight. A reduction in performance is expected
when the access is made to operate at the maximum permissible weight.
The performance of door operator may be affected by different independent variables like friction, offset
(balancing), environmental factors and so on. These factors may change the performance of the door
operator’s working life or parts. Furthermore, the surroundings must be considered to ensure the operator’s
durability and smooth operation.

1
2
4
3
9
5
7
8
10
12
6
13
Operates from 100 to 240 VAC
Automatic Door Operator
Manual
2
The AD500 is a swing door operator for a wide range of applications. It can be mounted on either side
of the door header for pull or push action, and suitable for single or double, inward or outward opening,
left or right handed doors. It also offers numerous adjustable features and can be integrated with electric
locks or access control systems to ensure all around safety.
Introduction
Product Features
Non - handed
Pull or push side mounting
Obstruction detection - If the door is obstructed during operation, the operator will stop
the door and reverse movement
1. Cover
2. Base plate
3. Top end plate
4. Bottom end plate
5. Control unit
6. Reducer
7. Turbine box
8. Turbine box cover
9. Motor
10. Track assembly
11. Track block
12. Sliding arm
13. Power On/OFF switch
Part Identification
Backup battery input for emergency power supply
Operates with infrared safety sensors, wall push buttons, card readers, or radio frequency devices
Adjustment of hold-up time, opening/closing speed, and opening angle
Easy integration with electric locking devices and access control systems
11

Specifications
Operating Voltage
Current Draw
100-240V AC +10/-15%, 50/60 Hz
3.2A max 77 W., 0.21 - 0.45 A average
Motor Specs
Voltage: 60 VDC
Maximum current: 2A
Power consumption: 98W
Maximum rotation frequency: 2900RPM
Maximum Torque Output 40NM
Opening Time (0° - 90°) Variable between 5 - 8 seconds
Closing Time (90° - 10°) Variable between 12 - 25 seconds
Hold Open Time Selectable 3, 10, 20, 30 seconds
Battery Specs 24 VDC, 8A
Door Width
Door Weight 45-110Kg (100-242lbs)
Electric Locking Device 24VDC, max. 250mA
Temperature -4 °F to +113 °F (-20 °C to +45 °C)
Relative Humidity
(non-condensing) Max 85%
Maximum Degree of Opening 80° - 110°
Net Weight 13.3Kg(30lbs)
Operator Body Dimensions 716(L) X 131(W) X 110(D) mm
Arm Length 15 3/4” (400mm)
Door Height 110” (2794 mm)
Track Length 24 7/16” (620mm)
3
Automatic Door Operator
Manual
28 3/16” (L) X 5 3/16” (W) X 4 5/16”(D)
29-48” (750-1219 mm)
28 3/16” (716mm)
(110mm)
(375mm)
(618mm)
24 5/16”
45/16”
14 3/4”
5 3/16” (131mm)
1 1/8” (29mm)

The AD500 automatic door operator uses a DC motor to open the door. It closes the door by motor
and spring force.
When an opening signal is received by the control unit, the door is opened at the operator-adjusted
opening speed until it reaches the back check position, where it decelerates to slow speed.
The door will stop at the Hold Open position and remain there.
When the hold open time has elapsed, the operator will close the door automatically. The door is
closed at the operator-adjusted speed until it reaches to the latch check position, where it
decelerates to slow speed. The door is kept closed by spring or motor force.
Hold Open Position
Deceleration
Back Check
Latch Check
Closing Speed
Automatic Door Operator
Manual
4
How the AD500 Works
Opening Cycle Closing Cycle
To Fully Opened
Opening Speed
Deceleration To Fully Closed

DC Power
Relay
Relay
Relay
Relay
Back Check / Latch Check Angle
Closing Speed
Opening Speed
(Device 2 Input)
Encoder
Motor
Backup Battery Input
(on hinge (pull) side)
(on opposite hinge (push) side)
Make sure the voltage
specified is correct for
the device.
For safety, we recommend using a
fail-safe electric lock in case of
emergencies or power interruptions.
Control Unit
LED1
LED2
LED3
5
Automatic Door Operator
Manual
Note:
1. Make sure that the wire length for backup
battery is less than 30mm.
2. Battery cannot not be connected to the
uninterruptible power supply system for
the building.
Activation
(Device 1 Input)
Auto
Hold
Push
&
Go
Manual
8123456
7
(Device 3 Input)
P
P2
P1
Auto
Auto
COM.
Hol
d
d Open
Push&GO
Manual
P1 P2
Black
Red
Blue
Green
White
P2
P1
IR Sensor Input
24VDC
Output
COM
Electric Locking
Device
(Fail-Safe)
OPB-500AD
Operation Controller
Call Point
N.O. COM COM
N.O.
Smoke Detector
(or Fire Panel)
Activation
SVR 1
SVR 2
SVR 3

Automatic Door Operator
Manual
6
Automatic Mode
(Locked status)
Functions on the Control Unit (see also page 5)
Function Description Diagram
Operator opens the door when
receiving an activation signal
and closes the door automatically.
*Default setting: Automatic mode
Push & Go
(Unlocked status)
As door is pushed open slightly,
the operator senses door
movement and opens the door
to the full-open position.
Manual Mode
(ON status)
Door can be manually opened
and then closed automatically.
Manual Mode
(OFF status)
Door cannot be manually
opened and then closed
automatically.
Hold Open (ON status)
Door can be held open after
the operator opens the door
to the full-open position.
Hold Open (OFF status)
Door cannot be held open after
the operator opens the door to
the full-open position.
Activation
Hold
Open
Auto/
Push &
Go
Manual
Activation
Hold
Open
Auto/
Push &
Go
Manual
Activation
Hold
Open
Auto/
Push &
Go
Manual
Activation
Hold
Open
Auto/
Push &
Go
Manual
Activation
Hold
Open
Auto/
Push &
Go
Manual
Activation
Hold
Open
Auto/
Push &
Go
Manual

7
Automatic Door Operator
Manual
+-
+-
*For automatic mode, 0.7 second motor start delay allows the electric locking device to release
first.
Function Description Diagram
Activation Input 1
(ON status)
Operator is activated by
Activation Device 1.
Activation Input 1
(OFF status)
Activation Input 2 Operator is activated by
Activation Device 2.
Activation Input 3 Operator is activated by
Activation Device 3.
Infrared Sensor Input
(On the hinge (pull) side)
Monitoring of IR impulse
or detection
Infrared Sensor Input
(On the opposite
hinge (push) side)
Monitoring of IR impulse
or detection
Activation
Hold
Open
Auto/
Push &
Go
Manual
Activation
Hold
Open
Auto/
Push &
Go
Manual
Activation Device 2
Activation Device 3
Functions on the Control Unit (see also page 5) (Continued)
Input Rating: 12VDC/75mA
Input Rating: 12VDC/75mA

Automatic Door Operator
Manual
8
Functions on the Control Unit (Potentiometer Settings)(see also page5)
ON/OFF Position Instructions
1
2
1234
ON
1234
ON
Automatic Mode
Push & Go
1234
ON
Position 3 ON
1234
ON
1234
ON
Position 3 OFF
Position 4 ON
Position 3 ON
Position 4 OFF
1234
ON
Position 3 OFF
Position 4 OFF
Functions on the Control Unit (DIP Switch Settings) (see also page 5)
Potentiometer Rotation Instructions
SVR1 SVR2 SVR3
Smal
Large
Manual Mode
Automatic Mode
Changing operation mode
Adjusting hold open time
Hold open 3 secs
Hold open 10 secs
Hold open 20 secs
Hold open 30 secs
SVR1 - Adjust the back check/ latch check angle. Turning clockwise
decreases the backcheck/latchcheck angle.
Fast Slow
Fast Slow
SVR3 - Adjust the opening speed. Turning clockwise decreases the
opening speed.
SVR2 - Adjust the closing speed.Turning clockwise decreases the
closing speed.
Autres manuels pour AD500
1
Table des matières