Geekpure RO4 Manuel

Geekpure
FILTER CARTRIDGE CONFIGURATION MAY BE SUBJECT TO CHANGE.
RO4
Portable Reverse Osmosis Water Filtration System
Installation and Maintenance Manual
INSTALLERS:
1.PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLING AND USING THIS SYSTEM.
2.IT IS RECOMMENDED TO WAIT UNTIL THE ENTIRE SYSTEM IS PRESSURIZED AND
RE-CHECK FOR ANY LEAKS BEFORE LEAVING INSTALLATION SITE.
3.THERE IS PROTECTION MATERIAL IN THE FILTERS, PLEASE KEEP FLUSH THE FILTERS
AT LEAST 30 MINUTES .
4.IT IS NORMAL FOR SOME BLACK CARBON FINES TO APPEAR IN THE WATER WHEN YOU
FLUSH NEW FILTERS.THE WATER PRODUCED SHOULD BE EMPTIED AND NOT USED.
5.DON'T FREEZE, ESPECIALLY RO MEMBRANE.
6.IF USING OZONE GENERATOR, PLEASE USE IT AFTER PRESSURE STORAGE TANK,
ORELSE IT WILL CAUSE EXPLOSION IF GAS FROM OZONE GENERATOR GOES INTO
PRESSURE STORAGE TANK.

How Your System Works...............................................................................
Technical Data of Membrane........................................................................
Before You Start............................................................................................
Tools Needed ...............................................................................................
System Location ..........................................................................................
Parts of the System ....................................................................................
Installation Steps ..........................................................................................
Installing the Filters .....................................................................................
Installing Tank Ball Valve ............................................................................
Installing the Faucet .................................................................................
Installing the Feed Water Diverter Valve......................................................
Installing the Waste Water Saddle ..........................................................
Installing the Unit ....................................................................................
Installing Tubing Into Fittings .................................................................
Installing Tubing Connections .................................................................
Sanitize System ............................................................................................
Flush System and Check Operation .............................................................
Filters Change Schedule...........................................................................
Spare Parts List.........................................................................................
Flow Diagrams.............................................................................................
Operation Specifications..............................................................................
Trouble Shooting..........................................................................................
Warranty........................................................................................................
1
1-2
2
3-4
4-5
6-7
7
7-8
8-9
9-10
11
11-12
12-13
13-15
15-16
16
17
17-18
18-19
20
20
21
22
Table of Contents

Geekpure RO4 Series system uses four stages of treatment to filter your water:
Stage 1 - Remove sand, dirt, sediment
Stage 2 - Remove chlorine, taste & odors, very fine particulates
Stage 3 - Reduce total dissolved minerals
Stage 4 - Polish water for refined taste
How Your System Works
Technical Data of Membrane
The system is compact and can be installed under the sink or another convenient place
close to the faucet. The closer the proximity to the faucet the better the system flow
rate.
Recommended Filter Change Schedule
Your filters require changing on a regular basis. Instructions to change them are on.
The schedule below is the minimum page 17 recommendation. Depending on your
water conditions the filters may need to be changed more often.
Disposable Filters
T33-PP
T33-CARBON
TW-1812-100G
RO5-COC10
Change Schedule
Every 6-12 months
Every 6-12 months
Every 15-24 months
Every 6-12 months
MEMBRANE
Type — TFC (Thin Film Composite)
Material — PA (Polyamide)
Charge — Negative
Configuration — Spiral-wound, Tapping
PERFORMANCE (NORMINAL)
Salt Rejection — 96%(minimum)
The stated performance is initial data taken after 30 minutes of opera-
tion based on the following conditions.
1

Before You Start
Your system contains filters which must be replaced periodically for proper
operation. (Refer to Filter Change Schedule on page 17.)
Read all steps and guides carefully before installing and using your RO system.
Follow all steps exactly to correctly install.
The system is designed to be used on potable water supplies only. If water is
non-potable, additional pretreatment will be required.
Concentration — 250ppm NaCl
Pressure — 60psig
Temperature — 77°F (25°C)
Recovery —15%
pH Range — 6.5 ~ 7.0
Note:Due to different temperature, different water pressure and feed water
quality, the product water capacity and pure water quality (TDS) is different.
That is the reason why we feel lower pure water capacity in the winter, but
higher in the summer. Please refer following diagram:
OPERATING LIMITS
Max.Operating Pressure — 125psi (0.86Mpa)
Max.Feed Flow Rate — 2gpm (0.45m3/hr)
Max.Feed Water TDS — 1000 ppm (if 2000 ppm, it is available,but out of
warranty, life time will be shorter.)
Max. Operating Temperature — 110°F (45°C)
Min.Operating Temperature — 40°F(5°C)
pH -3.0 ~10.0
Chlorine Concentration — <0.1ppm
Hardness <5GPG
2

Scissors FaucetWrench for
Membrane Housing
Tools Needed
Do not use for the treatment of water that is visually contaminated(cloudy) or
has an obvious contamination source, such as contamination by raw sewage.
All plumbing should be done in accordance with local codes and requirements.
Non-Booster pump models work on inlet water pressures of 40 psi (minimum) to
100 psi (maximum).If your house water pressure is over the maximum, install a
pressure reducing valve in the water supply line to the filter system.
Do not install the system outside, or in extreme hot or cold temperatures.
Temperature of the water supply to the R/O system must be between 40-110°F
/5-45°C.Do not install on hot water.
Plastic Tube Cutter 3/8" Variable Speed Electric
Drill; 1/8",1/4",1/2" Bits
Teflon Tape
Center Punch and
Hammer Monkey Wrench Faucet Bracket
3

Tank Tank ball valve Water Pipe
RO Membrane Clip Feed Water Diverter
Valve
Drain Clamp Mounting Clamp Manual
Your RO system may be installed under the sink, in a basement, or other location
depending on available space. It is recommended the system be installed in as close a
proximity to the faucet to ensure optimal system flow rate. If you have a water
dispenser or ice maker in your fridge, your RO system can be installed to provide the
feed water for these features but you should consult your fridge owners manual for
further information.
System Location
4

Guidelines for component placement are as follows:
Faucet should be placed near the sink where drinking/cooking water is normally
required. A 2" flat surface is required to mount the faucet if an existing hole for a
second faucet is not available.The thickness of the mounting surface should not
exceed 1-1/4" on the vertical or horizontal tailpiece. Refer to Figure 1.
Storage tank may be placed where it is convenient, within ten feet of the faucet.
Under the sink or in a nearby cabinet are excellent choices. If tank is located further
than ten feet from the faucet, use 1/2" tubing to reduce pressure drop. Full tanks may
weigh more than thirty pounds, so a sturdy shelf is required.
RO unit may be mounted on either side of the sink, in a cabinet or heated basement,
with nearby access to a potable, cold line and a drain.
NOTE: All components and tubing should be located in an area not exposed to
freezing temperatures or direct sunlight.
In the cabinet On the cabinetMounted on the wall
Feed water connection is accomplished with a feed water adaptor. Locate this assembly
as close to the R/O unit as possible. Connect to a potable, cold water supply line only.
NOTE: Softened water is preferred since it will extend the life of your R/O membrane.
Drain connection is accomplished using a waste water saddle valve which is designed to
fit around a standard 1-1/2" OD drain pipe. The drain saddle valve should always be
installed above (before) the drain trap and on the vertical or horizontal tailpiece. Refer to
Figure 2.
Figure 1
5

The following components make up your Reverse Osmosis
Drinking Water System:
1. PP Sediment removes larger particles such as sand, silt, and rust.
2. Coconut Carbon removes chlorine in the feed water to protect the reverse
osmosis membrane.
3. Reverse Osmosis Membrane reduces dissolved minerals, metals and salts.
During the process, harmful compounds are separated by the membrane and
the reject water goes to waste (drain).
Parts of the System
3/8" White Tube
3/8" White Tube
Pressure Tank
Feed Water
Drain
1/4" Red Tube
1/4" White Tube
Figure 2.
Typical Installation
Faucet
12
3
4
5
7
6
8
6

4. Post-Carbon Filter is provided for a final "polish" to provide great tasting
drinking water.
5. Storage Tank (2.8 Gal) holds filtered water, ready for use.
6. Feed Water Diverter Valve is connected to the cold water line to supply water
to the RO system.
7. Faucet (Standard) used to dispense RO water when needed.
Optional air gap and designer faucets are available.
8. Waste Water Saddle is connected to the drain to remove reject water from
the RO system.
1.RO Membrane
2.Faucet
3.Feed Water Diverter Valve
4.Waste Water Saddle
5.Unit Installation
6.Tubing Connections
7.Sanitize System
8.Flush System and Check Operation
Installation Steps
Installing the Filters
Install the Membrane
Water Inlet
ORings RO Membrane
Seal Ring
Membrane
Housing
Drain Water
Outlet
Pure Water
Outlet
Housing
Connection
Housing
Cap
7

Installing Tank Ball Valve
1 Remove the tube from the fitting and twist off the housing cap with
wrench
2.
.
Push the new membrane into housing
3 Put the housing cap back and tighten it.
4.
.
you should pull out old membrane before step 2 when you replace
new membrane.(you may use pliers if necessary.)
NOTE:Please ensure the RO System to work for about 30 minutes
before drinking the purified water for washing
1 2
3 4
The RO storage tank comes with a 1/4"*3/8" tank ball valve that must be
installed.
1.Apply 5-6 wraps of teflon thread sealant tape to the male thread on the
RO storage tank.
2.Install the ball valve and tighten it.
3.Connect 3/8" white tube.
8
Table des matières
Manuels Système d'eau populaires d'autres marques

Spirotech
Spirotech SPIROVENT SUPERIOR S250 Manuel utilisateur

Culligan
Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water... Manuel utilisateur

A.O. Smith
A.O. Smith Dura-Max AJH - 1000A - P Manuel utilisateur

Microline
Microline T.F.C.-4 Manuel

Eureka Forbes
Eureka Forbes Aquaguard Select Manuel utilisateur

Cetetherm
Cetetherm AquaEfficiency Manuel utilisateur