GE E2 Series Manuel utilisateur

OSMONICS
E2/EZ2 SERIESTM
WATER PURIFICATION
MACHINES
INSTALLATION, OPERATION,
AND MAINTENANCE
MANUAL
GE Infrastructure
Water & ProcessTechnologies

Distributor Information
Distributor:
Contact:
Phone:
Fax:
Email:
Machine Information
Installation Date:
Model Number:
Serial Number:
Service Assistance
Consult the Troubleshooting Section of this manual
(Section 2.19). If the problem cannot be identified and correct-
ed, contact your distributor. Prior to making the call, have the
following information available:
Model Number Daily Log Sheets
Serial Number Operating Parameters
Installation Date Description of Problem
Spare Parts
Contact your distributor to order spare parts. Refer to the
Spare Parts List (Technote 109).

INSTALLATION, OPERATION,
AND MAINTENANCE MANUAL
E2/EZ2-SERIES
WATER PURIFICATION MACHINES
TABLE OF CONTENTS
Page
2.0 INSTALLATION 1
2.1 Mounting the Unit 1
2.2 Plumbing 1
2.3 Plumbing Connections 1
2.4 Feed Water Requirements 2
2.5 Transporting Pure Water (Permeate) to Point-of-Use 2
2.6 Machine Control 3
2.6.1 Economy Model 3
2.6.2 Deluxe Model 3
2.7 Single-Phase Electrical 3
2.8 Machine Start-Up Preparations 3
2.8.1 Pretreatment for Water Purification 3
2.8.2 Machine Start-Up Preparation 4
2.9 Machine Start-Up 4
2.10 Recovery 7
2.11 Permeate Back Pressure Correction Factors 8
2.12 Operation and Maintenance 9
2.13 Pre-Filter Cartridge 9
2.14 Daily Flushing 9
2.15 Membrane Element Cleaning 10
2.16 Membrane Element Removal 12
2.17 Membrane Element Replacement 12
2.18 Troubleshooting 15

LIST OF FIGURES
Page
Figure Description
2.1 Flow Control Center 6
2.2 Closed Loop Membrane Element Cleaning 11
2.3 Membrane Element Installation 13
2.4 Membrane Element Direction for Installation 14
LIST OF TABLES
Table Description
2.1 E2/EZ2-Series Machine Piping Connections 1
2.2 E2/EZ2-Series Feed Water Requirements 2
2.3 E2/EZ2-Series Primary Pressure Range 5
2.4 Flow Specifications for E2/EZ2-Series Machines 7
2.5 Permeate Back Pressure Correction Factors 8
NOTE:This manual, along with all GE Infrastructure manuals, is available at
www.ge.water.com.

1
2.0 INSTALLATION
2.1 Mounting the Unit
When installing your new GE Osmonics reverse osmosis (RO) machine, allow at least
45-inches (114.3 cm) above the machine for membrane element removal and loading. If
space is not available, the entire membrane element housing can be removed for
membrane element change-outs. If the membrane element housings are to be removed to
change-out the membrane elements, at least 25-inches (65.3 cm) is required at one end of
each membrane element housing and 6-inches (15.2 cm) behind the machine.
2.2 Plumbing
The feed water source must be able to provide water quantity and pressures to maintain an
operating feed water pressure of 30 - 60 psi (2.1 - 4.1 bar). If the feed water pressure with
the machine is in excess of 60 psi (4.1 bar) or fluctuates by more than 5 psi
(0.34 bar) a pressure regulator should be installed upstream of the machine inlet. If prop-
er water pressure cannot be maintained to the RO, a booster pump may need to be installed
in front of the pretreatment to provide the proper water quantity and pressure for the oper-
ation of the machine.
2.3 Plumbing Connections
Connect proper size drain line to the concentrate outlet (Table 2.1, E2/EZ2-Series
Machine Piping Connections) and run to an open drain. The drain capacity needs to be
large enough to properly drain the feed water flow of the RO.
Table 2.1
E2/EZ2- Series Machine
Piping Connections
CONNECTIONS
Inlet
inch (cm)
Permeate
inch (cm)
Concentrate
inch (cm)
0.38 (0.96)
0.38 (0.96)
0.38 (0.96)

2.4 Feed Water Requirements
The following feed water requirements must be met before installing your E2/EZ2-Series
machine to ensure quality permeate and extended membrane element life. Refer to
Table 2.2 (E2/EZ2-Series Feed Water Requirements) for feed water information.
Table 2.2
E2/EZ2-Series Feed
Water Requirements
* American Standard for Testing Materials
2.5 Transporting Pure Water (Permeate) to Point-of-Use
Pure water, or permeate, is in an aggressive state and should only be transported from the
machine to the point-of-use in food grade flexible nylon, stainless steel (SS) tubing, or
polyvinyl chloride (PVC) material for the inlet, permeate, and concentrate piping sizes.
Refer to Connections (Table 2.1, E2/EZ2-Series Machine Plumbing Connections) for
inlet, permeate, and concentrate piping sizes.
WARNING: MACHINE DAMAGE MAY OCCUR IF PERMEATE BACK PRES-
SURE EXCEEDS 60 PSI (4.1 BAR) DURING OPERATION.
2
Temperature
Inlet Pressure
Chlorine
(continuous feed)
Operating pH
Silt Density Index
(SDI)
Typical: 50° - 85°F (10° - 29°C)
Limits: 33° - 104°F (0.60° - 40°C)
Minimum: 30 psig (2.1 barg)
Maximum: 60 psig (4.1 barg)
0 parts per million (ppm)
5.5 - 8.5
Less than or equal to 5 to minimize
membrane element fouling and
extend cleaning intervals. Refer to
ASTM* Standard D4189.

2.6 Machine Control
2.6.1 Economy Model
To remotely control the Economy Model (ECN) with float switches and/or pre-
treatment lockout, remove the jumper between terminals 4 and 5 and wire in the
float switches or pretreatment components in series. After all field wiring is com-
plete and complies with local and national electrical codes, move onto
Section 2.7 (Single-Phase Electrical).
NOTE:External control contacts are normally closed, dry contacts.
2.6.2 Deluxe Model
To remotely control the Deluxe Model (DLX), with float switches and/or pre-
treatment lockout, remove the jumper between terminals 2 and 3 and wire in the
float switches and pretreatment in series. After all field wiring is complete and
complies with local and national electrical codes, move onto Section 2.10
(Pretreatment for Water Purification).
NOTE:External control contacts are normally closed, dry contacts.
2.7 Single-Phase Electrical
Always check voltage tag on the machine to ensure the correct voltage and amperage is
available.
The E2/EZ2-Series machines are shipped as either 120 Volt 60 Hertz or 220 Volt
50 Hertz from the factory. Machines should always be connected to a 15 Amp single-
phase dedicated circuit. The circuit provided should be a separately fused disconnect with
the proper protection for the Hp and Amp draws of the machine. Reverse osmosis (RO)
machines with 115 Volt circuit include an 8-foot (2.4 m) electrical cord which plugs into
a single-phase outlet. All machines shipped with a 220 VAC single-phase power require-
ment are shipped with an 8-foot (2.4 m) electrical cord, but customers must provide
electrical plug. All field wiring must comply with applicable local and national electrical
codes.
2.8 Machine Start-Up Preparations
2.8.1 Pretreatment for Water Purification
A water analysis of your feed water should have been performed, as part of the
planning and engineering that went into developing your RO system.
The water analysis will provide information on what type of pretreatment may be
required and what recovery the machine can be run at on the feed water provid-
ed. If the machine is moved to a different water source, a new water analysis
should be taken before operating the machine.
3

Your RO is designed to operate on softened tap feed water with an SDI of 5 or
less. The pH should be in a range of 5.5 - 8.5. Exposure to any levels of chlo-
rine may cause irreversible damage to the Thin-layer composite (TLC) polyamide
(PA) membrane elements in your machine. Daily water checks are recommend-
ed to ensure the integrity of your pretreatment and RO system. Refer to
Table 2.2 (E2/EZ2-Series Feed Water Requirements).
2.8.2 Machine Start-Up Preparation
Check the function and integrity of your pretreatment equipment. Ensure that
your water softener and activated carbon filters have been leaked checked and
properly flushed, before starting up your RO machine.
WARNING: IMPROPERLY FLUSHED PRETREATMENT MAY
CAUSE SERIOUS RO MACHINES PROBLEMS AT
START-UP.
WARNING: NEVER OPERATE THE MACHINE WITH THE CON-
CENTRATE OR PERMEATE LINES BLOCKED.
SEVERE DAMAGE TO THE UNIT MAY RESULT.
2.9 Machine Start-Up
STEPS
1. Turn the feed water supply to the machine ON, while checking for leaks in the
pretreatment and inlet feed water lines.
2. Check to ensure power to the motor is de-energized and the ON/OFF button, on
the machine, is in the ON position.
3. Plug in the factory-supplied power cord.
NOTE:Fifty (50) Hertz models require customer supplied plug compatible
with existing outlet.
4. For initial start-up, redirect the permeate and concentrate lines to the drain for
start-up flush.
5. Open the concentrate and recycle flow control valves two (2) complete turns.
These valves are positioned on the flow control plumbing (Figure 2.1, Flow
Control Center).
WARNING: ONCE MACHINE IS OPERATING, FLUSH CONCEN-
TRATE AND PERMEATE TO THE DRAIN FOR
20 - 30 MINUTES. FLUSHING ENSURES ALL BIOCIDES
AND CONTAMINATES ARE REMOVED FROM THE
MEMBRANE ELEMENTS.
4

6. Turn the ON/OFF button on the machine ON.
7. As the pump starts to build pressure, begin to adjust the valves in the following
manner: start by slowly closing the concentrate valves while slowly opening the
recycle valve (Figure 2.1, Flow Control Center).
CAUTION:Monitor machine to ensure inlet pressure of 30 - 60 psi
(2.1 - 4.1 bar) is maintained during operation.
8. After 20 - 30 minutes of flushing permeate to the drain, ensure all chemical
residue has been removed before hooking up to point of use.
While operating, the pressure range should never operate outside of the pressure
ranges displayed in Table 2.3 (E2/EZ2-Series Primary Pressure Range).
Table 2.3
E2/EZ2-Series
Primary Pressure Range*
* Primary pressure temperature for normal operation is 77°F (25°C).
CAUTION:The E2/EZ2-Series must not operate outside the ranges listed
above.
NOTE: Optimum recovery will vary according to feed water quality.
The concentrate valve is drilled, and when completely closed the machine is run-
ning at the correct concentrate flow for a 75% recovery (Table 2.4, Flow
Specifications for E2/EZ2-Series Machines).
If the temperature of the inlet feed water is not 77°F (25°C) use the Temperature
Correction Factor Table (Technote 113). The proper adjustment of the recycle and
concentrate valves are critical to the correct operation of the machine.
5
Operating
Pressure
Operating
Range
220 psi
(15.2 bar)
165 - 250 psi
(114. - 17.2 bar)
E2/EZ2-Series

9. Complete the Start-Up Data Sheet (Technote 101). The Start-Up Data Sheet and
the Daily Log Sheet (Technote 106) are invaluable in diagnosing the performance
of the equipment, and must be be kept for reference. If you have questions con-
cerning the operation of your machine or the method of data recording, contact
your distributor or the manufacturer.
Figure 2.1
Flow Control Center
CAUTION: Once the machine is running, with orifices, adjust pressures and
flows to the correct measure, flush machine to drain for
30 - 45 minutes.
CAUTION:The E2/EZ2-Series machines are designed to run at 50% recov-
ery. To confirm flows are correct, check Table 2.4 (Flow
Specifications for E2/EZ2-Series Machines). To correct any
temperature variations, check Table 2.4. If your E2/EZ2-Series
machine is operating under permeate back pressure to point of
use, refer to Table 2.5 (E2/EZ2-Series Permeate Back Pressure
Correction Factors).
CAUTION:Machine performance is based on a feed water temperature of
77°F (25°C). If feed water temperature is other than
77°F (25°C), reference Table 2.4 (Temperature Correction
Factors) to confirm machine’s performance
6
Pressure Gauge
Feed Water
Inlet
Concentrate Valve
Recycle Valve
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels GE Système d'eau

GE
GE AvantaPure Manuel utilisateur

GE
GE GXULQ Manuel utilisateur

GE
GE Merlin Guide de l'utilisateur

GE
GE MERLIN 1255052 Manuel

GE
GE 400 Series Manuel utilisateur

GE
GE Autotrol Performa ProSoft 960 Series Manuel utilisateur

GE
GE GXPL03H Guide d'installation

GE
GE GXSG30V Mode d'emploi

GE
GE GNPR40L Mode d'emploi
Manuels Système d'eau populaires d'autres marques

Spirotech
Spirotech SPIROVENT SUPERIOR S250 Manuel utilisateur

Culligan
Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water... Manuel utilisateur

A.O. Smith
A.O. Smith Dura-Max AJH - 1000A - P Manuel utilisateur

Microline
Microline T.F.C.-4 Manuel

Eureka Forbes
Eureka Forbes Aquaguard Select Manuel utilisateur

Cetetherm
Cetetherm AquaEfficiency Manuel utilisateur