GE Interlogix Aritech CS250 Manuel utilisateur

CS250 LCD Keypad
User Manual
May 2004
Version 1.7
g
GE Interlogix

The CS250 system complies with EN50131-1 Security Grade 2 and Environmental Class II if installed according to
these instructions and with an external communicator (not supplied). Where no communicator is used, the system
complies with Security grade 1.
Aritech is a GE Interlogix brand.
www.aritech.com
Copyright
© 2004 GE Interlogix B.V.. All rights reserved. GE Interlogix B.V. grants the right to reprint this manual for internal
use only. GE Interlogix B.V. reserves the right to change information without notice.

CS250 User Manual 3
CONTENTS
LCD keypad...................................................................................... 6
Using keyfobs ................................................................................... 8
Turning on the alarm system............................................................ 9
Disarming the system..................................................................... 10
Turning off the system after an alarm............................................. 11
Inhibiting (excluding) one or more zones ....................................... 12
Inhibiting tampered zones .............................................................. 13
Inhibiting a system tamper ............................................................. 14
Life safety functions........................................................................ 15
Duress arm/disarm ......................................................................... 16
Resetting fire detectors .................................................................. 17
Changing user codes ..................................................................... 18
Viewing user attributes ................................................................... 19
Setting up a time limited user code ................................................ 20
Deleting user codes ....................................................................... 21
Viewing open zones ....................................................................... 22
Viewing inhibited zones.................................................................. 22
Viewing system faults ..................................................................... 23
Performing a bell test ..................................................................... 24
Reading the event log .................................................................... 25
Setting the system time and date ................................................... 26
Setting the keypad audio level ....................................................... 27
Enabling and disabling the backlight.............................................. 27
Glossary ......................................................................................... 28
Service messages .......................................................................... 29
EN50131-1 ..................................................................................... 31

CS250 User Manual 4
MENU MAP
The CS250 main menu is shown below. Once you enter a user code you can scroll through the main menu and press the OK button to access the
sub-menus. Some options are only visible if you have the correct attributes or have entered a super user code.
Disarm Options
Arm Options
Event Log
Armed Zones
Show Open Zones
Show Tampers
Diagnostics
Inhibits
Full Disarm
Disarm 1 PARTAR
Disarm 2 PARTAR
Full Arm
Arm 1 PARTARM
Arm 2 PARTARM
Partarm
Quick Arm
Quick Partarm Arm 1 PARTARM
Arm 2 PARTARM
Arm 1 PARTARM
Arm 2 PARTARM
User Log
Inhibit Zone
Inhibit Zon Tam
Inhibit Sys Tam
Show Open Zones
Show Ex Zones
Zone Tamp
Sys Tamp
Zone Tests
Show Tampers
Walk Test
Zone Tamp
Sys Tamp
Software Rev
Panel Model
Software
System Log
System Faults
Keypad Test
Chime Test
Int Bell Test
Ext Bell Test
System Status
Force Arm
Quick Force Arm
Force Partarm
Quick Force PG Arm 1 PARTARM
Arm 2 PARTARM

CS250 User Manual 5
Users User Codes User 1
User 2
User 3 ...
Verify Code
User Time Limit
Duress Code Area 1
Area 2 Set Code Verify Code
MENU MAP
Inhibit
Full Arm
Arm 1 PARTARM
Arm 2 PARTARM
Full Disarm
Disarm 1 PARTAR
Disarm 2 PARTAR
Change Code
Super User
Area 1
Area 2
SYS
Language 1
Language 2
Language 3
Installr Access Limit Access
Identify Fob
Function Keys Function Key1
Function Key2
Function Key3
Unused
FullArm
Arm 1 PARTARM
Arm 2 PARTARM
Force Arm
Quick Arm
Force Partarm 1
Force Partarm 2
Quick Partarm 1
Quick Partarm 2
Quick ForceArm
Quick Force PG 1
Quick Force PG 2
Fire Reset
Medical Alert
PA
Fire Alarm
Inhibit Zone
Reset Fire
Time/Date Date
Time
Exit Menu
System Settings
New Code
Attributes
Area
User Name
Keyfob
Enable Inst Code
Language
Disable Inst Code
Set Code
Area 1
Area 2
SYS
User Codes
Install Fob
Remove Fob
Keyfob Func
Start Ud
Voice Phone Num
Stop Call
Show All Attrbts

CS250 User Manual 6
LCD KEYPAD
Power (green): When lit, the
system is powered up. When
flashing you are in menu mode
or there is a mains fault or line
fault.
Trouble (orange): When
flashing, the system itself may
have a problem.
Status (red): When lit, the
system is armed. When
flashing, an alarm was
triggered.
NO: Press this key to cancel a
task or step back in a menu.
Function keys: These can be
programmed to perform certain
tasks without having to enter a
code first.
F1
F2
F3
Navigation Keys: Press to scroll
through menus on the LCD display.
OK: Press this key to complete a
step.
Hash key: Press this key before
and between parts of a task.

CS250 User Manual 7
LCD KEYPAD
Numeric keys
There are 10 keys numbered 0-9. They are used for entering codes,
programming tasks and retrieving information.
Function Keys
The function keys F1, F2, and F3 allow a task to be performed instantly
without a code being entered. For example, F1 can be programmed so
that a full arm occurs by just pressing this key. They are generally set up
by the installer.
The function key must be pressed and held for 2 seconds or pressed
twice within 2 seconds to perform the task.
Navigation keys
These are marked with an up and down arrow. They are used to scroll
through the menus.
Command keys
These are the 3 keys marked OK, NO and #. They are used for entering
and cancelling commands:
OK: Confirms a command. It is generally pressed once at the end of a
task.
NO: Cancels a command before the OK key is pressed. It is also used
to clear the display.
#: Entered before and between parts of a task. For example, it is
pressed between the hour and the minute when setting the time.
Buzzer sounds
Exit: A continuous beep for the pre-programmed exit time.
Entry: Short beeps for a time programmed by the installer or until
the system is disarmed.
Medical alert: Arapid beep. If there is a communicator and the
report is successfully received by an ARC, it reduces to a slower
beep until a user code is entered.
Reject: 3 slow beeps. This sounds if an incorrect entry is made at
the keypad.
Wrong key: Adouble beep. This sounds if an incorrect key is
pressed.
Fire Alarm: Beep 3 seconds on, 1 second off. This sounds when a
fire alarm is generated.
System state
The installer can program the system so that the LCD displays
whether it the system is armed or disarmed.

CS250 User Manual 8
Lock
Unlock
USING KEYFOBS
Installing, removing and programming keyfobs
To install a keyfob, select Users - User Codes - User n - Keyfob - Install Fob and press the lock and unlock buttons on the keyfob simultaneously.
To remove a keyfob, select Users - User Codes - User n - Keyfob - Remove Fob.
To program a keyfob, select Users - User Codes - User n - Keyfob - Keyfob func.
Keep a note of the button functions here:
Lock
Unlock
Light
Star
RF Settings RF Settings
OFF
A
C
A+C
IR Settings
RF keyfob
If you have an RF receiver with your CS250 system, you can use an RF keyfob.
There are 2 types of keyfob, one with 2 buttons and one with 4 buttons. The buttons can be programmed to perform different
functions.
An indicator LED flashes while the keyfob is transmitting to show that it is in use. The transmission range of the keyfob depends
on the battery life. You should replace the battery if the transmission range decreases.
IR keyfob
This is a 3-button device that can send commands via an infra-red keypad. There is 1large button and 2 smaller buttons.The
transmission range of the keyfob depends to a small extent on lighting conditions but is generally up to 5 metres. An indicator LED
flashes while the keyfob is transmitting to show that it is in use.
There are 2 types of keyfobs that can be used with the system. These are wireless (RF) keyfobs and infra-red (IR) keyfobs.

CS250 User Manual 9
TURNING ON THE ALARM SYSTEM
Full arming turns on the entire system.
1 Enter the user code. ..........
2 Press OK. ....................................................................................
3 Press OK. The buzzer sounds and the system begins to arm....
4 Leave the building. ......................................................................
User Menu
Arm Options
Arm
Full Arm
Arming......#
Enter Code
****
Area 1 Arming
Leave Now

CS250 User Manual 10
DISARMING THE SYSTEM
This disarms the system if no alarm events have taken place.
1 Enter the user code. ..........
2 Press OK. ....................................................................................
3 Press OK. The system disarms...................................................
User Menu
Disarm Options
Disarm
Full Disarm
Thu 22 Jan 09:31
Area 1 Disarmed
Enter Code
****
Table des matières
Autres manuels GE Interlogix Clavier